background image

GAS LEAKAGE DETECTOR, 

i4H-

GA-2S 

INTRODUCTION 

The 

i4H-

GA-2S is a gas detector, it uses electrochemical sensor to detect 

LNG(Liquefied natural gas) and LPG (Liquefied petroleum gas

).

  

The 

i4H-

GA-2S is built in a radio transmitter, it sends check-in signal to 

i4H-

LS-20 

base unit regularly, and sends alarm signal when it’s triggered by LNG or LPG. 

INSTALLATION 

1. Put the 

i4H-

GA-2S close to

i4H-

LS-20 Base Unit, and plug in 

the power cord of the 

i4H-

GA-2S. 

2. Keep pressing the Clear/Enroll
Button on 

i4H-

LS-20 for over 3 

seconds and then release it, the 

i4H-

LS-20 would keep beeping and all 
LEDs blink. This means the system is 
ready for enrolling device. 

3.Within 30 seconds press the Test Button on the gas detector. If you hear 3 short
beeps soon later then enrolling successes, otherwise you will hear one long beep after 
30 seconds that means enrolling fails, you have to repeat enrolling action.     
Note: Avoid activating any other sensors during the 30 seconds Device Enroll period. 

Remarks: In case you have to change the sensor/transmitter’s attribute,

 you can do that 

on the cloud directly, or use supplied HyperSecureLink software to change them by 
computer.   

4. After the power of the 

i4H-

GA-2S is plugged in, the red LED lights up for 1 minute 

or so,

 

and then the green LED lights up while the red LED extinguishes. To test the

 

i4H-

GA-2S, you can put a gas lighter closely to the bottom of the detector, and then 

leak

 

its gas for about 3 seconds. The 

i4H-

GA-2S would beep with the red LED light 

up.

 

Meanwhile, it would trigger 

FIRE

 alarm of the 

i4H-

LS-20 system.

Important notice: The 

i4H-

GA-2S uses an electrochemical sensor whose 

life is about 5 years; the user should replace a new 

i4H-

GA-2S before its 

life time expires.

 

SPECIFICATIONS: 

Detection: LNG (Liquefied Natural Gas) and LPG (Liquefied Petroleum Gas) 
Alarm Sensitivity: 8,000ppm for LNG, 3,300ppm for LPG 
Power: 120V or 230V AC as requested. 
Power Consumption: max. 2W 
Buzzer: built in 
Size: 88 x 45 x 123.5 mm 
Weight: about 309g  

ALARM

LED

POWER 

INDICATOR

TEST

TEST SWITCH

GAS
DETECTOR

(Red) 

(Green) 

Reviews: