Radio Repeater,
i4H-
RP-2SN
INTRODUCTION
The repeater
i4H-
RP-2SN is used to extend the RF distance of
i4Home
system. To avoid useless retransmission
and minimize the possibility of radio interference, the repeater only relays the sensors/transmitters' signal which have
been enrolled in the repeater. Maximum 10 sensors/transmitters can be enrolled in a repeater.
ENROLL THE REPEATER IN THE BASE UNIT
1.
Turn off the power and battery switch of the repeater.
2.
Keep pressing the Clear/Enroll Button on
i4H-
LS-20 for over 3 seconds and then release it, the
i4H-
LS-20
would keep beeping and the all LEDs blink. This means the system is ready for enrolling device.
3.
Within 30 seconds, plug the power adapter of the repeater, the repeater would generate a beep, in the mean time the
Green LED turns on for one second and the repeater sends its ID to the Base Unit for enrolling. If you hear 3 short
beeps from the
i4H-
LS-20 soon later then enrolling successes, otherwise you will hear one long beep after 30
seconds
that means enrolling fails, you have to repeat enrolling action.
4. Turn on the battery switch for battery charging.
ENROLL THE SENSORS IN THE REPEATER
1. For the first time you press the Enroll Button of the repeater (with the tip of a paper clip or a ball pen) for 1 second, it
would generate one beep, and the red LED turns on. Then you press the TEST button on the sensor/transmitter (or
activate its RF transmission) which needs to enroll. If the repeater receives a valid RF signal within 30 seconds, it would
generate two beeps, and the enrolling terminates. Otherwise, it would generate one beep after 30 seconds.
Note:
1) Please keep the enrolling process as short as possible to prevent the repeater from enrolling any unwanted
sensor’s signal in the air.
2). In case the sensors have been mounted already, for the sake of convenience, you may simply turn on repeater’s
battery switch without connecting a power adapter, and then bring the repeater closely to the sensors to enroll the
codes.
i4H-LS-20
Base Unit
S1
S3
S2
Fig. 2
S8
S7
i4H-
RP-2SN
(can't reach Base Unit)
Fig. 1
Red LED
Green LED
Enroll Button
Battery Switch
Up for On
Power In
(can't reach Base Unit)