background image

Dummy Plug

 

 

 

     

SCON 

First Step Guide   

Ninth Edition

 

 

Thank you for purchasing our product. 
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to   
this First Step Guide to ensure correct use. This Instruction Manual is original. 
 
 
 
 
 

  Using or copying all or part of this Instruction Manual without permission is prohibited. 

  The company names, names of products and trademarks of each company shown in the sentences are registered trademarks.

 

 

Product Check 

This product is comprised of the following parts if it is of standard configuration. 

If you find any fault in the contained model or any missing parts, contact us or our distributor. 

1. Parts (The option is excluded.) 

No. 

Part Name 

Model 

Reference 

1 Controller 

Main 

Body 

Refer to “How to read the model plate”, 
“How to read controller model” 

 

Accessories 

SMSTB2.5/5-ST-5.08AU  (Maker: Phoenix Contact)

 

Enclosed in CA/CB/C Type 

DeviceNet Specifications 

MSTB2.5/5-STF-5.08AUM (Maker: Phoenix Contact) 

Enclosed in CAL Type 

SMSTB2.5/5-ST-5.08AU  CA (Maker: Phoenix Contact)  Enclosed in CA/CB Type 
MSTB2.5/5-STF-5.08AU  CAL (Maker: Phoenix Contact)  Enclosed in CAL Type 

CC-Link Specifications 
(Enclosed in terminal 
resistance) 

MC1.5/5-ST-3.81 

C (Maker: Phoenix Contact)  Enclosed in C Type 

PROFIBUS-DP Specifications 

Prepare D-sub 9-pin (female) connector. 

CompoNet Specifications 

Prepare flat cable connector dedicated for CompoNet. 

MECHATROLINK-

/

 Specifications  Connector recommended for MECHATROLINK-

.

 

Fieldbus 
Connector 

MECHATROLINK-

 Specifications  Flat cable recommended for MECHATROLINK-

.

 

 

~750W Motor 

FMC1.5/4-ST-3.5 

(Maker: Phoenix Contact) 

3  System I/O Plug 

3000W~Motor 

FMC1.5/6-ST-3.5 

(Maker: Phoenix Contact) 

4  Power Supply Plug for Brake 

MC1.5/2-ST-3.5 

(Maker: Phoenix Contact) 

Applicable Cable Size 
1.25mm

2

 to 0.5mm

2

 

(AWG16 to 20) 

~750W Motor 

MSTB2.5/6-STF-5.08 

(Maker: Phoenix Contact) 

Applicable Cable Size 
Controller: 0.75mm

(AWG18) 

Motor: 2.0mm

2

 (AWG14) 

AC Power 
Supply Plug 

3000W~Motor 

PC5/6-STF-7.62 

(Maker: Phoenix Contact) 

Applicable Cable Size 
Controller: 0.75mm

(AWG18) 

Motor: 3.3mm

2

 (AWG12) 

6 Absolute 

Battery 

AB-5 

Enclosed in Absolute Type 
(Excluded for battery-less 
absolute) 

7 Dummy 

Plug 

DP-5 

Enclosed in SCON-CGAL/CGB 

External Regenerative Resistor Unit 
Connecting Plug (3000W~ Motor) 

GIC2, 5/2-STF-7.62       

 

(Maker : Phoenix Contact) 

Applicable Cable Size 
0.75mm

2

       

 

(AWG18)

 

9  Connector for Multi Function 

Plug:10114-3000PE, Shell:10314-52F0    (Maker : 3M)  Enclosed in Servo Press Type

 

10  First Step Guide 

 

 

11  Instruction Manual (DVD) 

 

 

12 Safety 

Guide 

 

 

 

 

 
 
 

 

 
 
 

 
 
 
 
 
 
 
 
 
 

 
 
2. Teaching Tool (Option) 

A teaching tool such as PC software is necessary when performing the setup for position setting, parameter setting, etc. 

that can only be done on the teaching tool. Please prepare either of the following teaching tools such as PC software. 
(Note)  TB-01/01D/01DR are not applicable for CC-Link IE. 

No. 

Part Name 

Model 

1  PC Software (RS232C converter adapter and external equipment communication cable are included) 

RCM-101-MW 

2  PC Software (USB converter adapter, USB cable and external equipment communication cable are included) 

RCM-101-USB 

3  Touch Panel Teaching TB-01(Standard/with dead-man switch attached on the left/with dead-man switch attached on the right) 

TB-01/01D/01DR 

4  Touch Panel Teaching TB-02 (Standard/with dead-man switch attached) 

TB-02/02D 

5 Data 

Setter 

TB-03 

TB-03 

3. Instruction manuals related to this product, which are contained in the Instruction manual (DVD). 

No. 

Name 

Manual No. 

1  SCON-C Controller Instruction Manual 

ME0161 

2  SCON-CA/CAL/CGAL Controller Instruction Manual 

ME0243 

3  SCON-CB/CGB Controller Instruction Manual/Servo Pressing Function Instruction Manual 

ME0340/ME0345 

4  CC-Link (Remote I/O Type) Instruction Manual (for SCON-C)/(For excluding SCON-C) 

ME0123/ME0254 

5  DeviceNet (Remote I/O Type) Instruction Manual (for SCON-C)/(For excluding SCON-C) 

ME0124/ME0256 

6  PROFIBUS-DP (Remote I/O Type) Instruction Manual (for SCON-C)/(For excluding SCON-C)

ME0153/ME0258 

7  CompoNet Instruction Manual (For excluding SCON-C) 

ME0220 

8  MECHATROLINK Instruction Manual (For excluding SCON-C) 

ME0221 

9 MECHATROLINK-

  Instruction Manual (for SCON-CA) 

ME0317 

10  CC-Link IE Instruction Manual 

ME0389 

11  PC Software 

RCM-101-MW/ RCM-101-USB Instruction Manual 

ME0155 

12  Touch Panel Teaching 

TB-01/TB02/TB03 Position Controller Instruction Manual 

ME0324/ME0355/ME0376

 

4. How to read the model plate 

 

 

 

5. How to read controller model 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Basic Specifications

 

List of Specifications 

SCON-C/CA/CB/CGB 

Item 

Less than 400W 

400 to 750W 

3000 to 3300W 

SCON-CAL/CGAL

Corresponding Motor Capacity 

12W to 399W 

400W to 750W 

3000 to 3300W 

12W to 200W 

Power-supply Voltage 

Single-Phase 

100 to 115V AC 

Single-Phase 

200 to 230V AC 

(Power-supply 

Fluctuation ±10% or less)

Single-Phase 

200 to 230V AC 

(Power-supply 

Fluctuation ±10% or less)

Three-Phase 

200 to 230V AC 

(Power-supply 

Fluctuation ±10% or less)

Single-Phase 

100 to 115V AC 

Single-Phase 

200 to 230V AC 

(Power-supply Fluctuation 

±10% or less) 

Power-supply Voltage 100V 

AC 

 

 

Rush 

Current 

*1

 

Power-supply Voltage 200V 

AC 

30A (Controller side), 

80A (Drive side) 

30A (Controller side), 

80A (Drive side) 

40A (Controller side), 

40A (Drive side) 

30A (Controller side), 

80A (Drive side) 

3.0mA 3.5mA 

3.0mA 

Leak Current 

*2

 

Primary side when noise filter is connected to power supply line 

Load Capacity, Heat Generation 

Refer to Power Capacity and Heat Generation 

Power Supply Frequency 

50/60Hz 

PIO Power Supply 

*3

 24V 

DC±10% 

Power Supply for Electromagnetic Brake 

(for actuator equipped with brake) 

24V DC±10%  1A (MAX.) 

(supplied from external equipment) 

24V DC±10% 
0.1A (MAX.) 

(Note) Necessary to 

supply 1.5A (max.) to 

actuator separately

24V DC±10% 
1A (MAX.) 

 

Transient Power Cutoff Durability 

SCON-C

 : 

10ms (50Hz), 8ms (60Hz) 

SCON-CA/CB/CGB

 : 

20ms (50Hz), 16ms (60Hz) 

20ms (50Hz),   

16ms (60Hz) 

Motor Control System 

Sine Wave PWM Vector Current Control 

Corresponding Encoder 

• 

Incremental Serial   

• 

Absolute Serial 

• 

ABZ (UVW) Parallel 

• 

Battery-less Absolute 

• 

Incremental Serial

•  

Absolute Serial 

Encoder Resolution 

• 

Battery-less Absolute (ISB): 131072 pulse/rev 

• 

Battery-less Absolute (RCS2/3): 16384 pulse/rev 

* In any models other than above, refer to instruction manual of each actuator. 

Actuator Cable Length 

MAX. 20m 

Serial Communication Interface 

RS485 : 1CH … based on Modbus Protocol RTU/ASCII    Speed : 9.6 to 230.4Kbps 

Control available with serial communication in the modes other than the pulse train 

PIO  

Specifications

Signal I/O dedicated for 24V DC (selected from NPN/PNP) … Input 16 ports max., 

output 16 ports max. 

External Interface 

(Each the dedicated 

controller) 

Fieldbus  

Specifications

DeviceNet, CC-Link, PROFIBUS-DP, CompoNet *, MECHATROLINK-

/

*,  

EtherCAT *, EtherNET/IP *, PROFINET IO *, MECHATROLINK-

*, CC-Link IE *   

(* Some types cannot connect it.) 

PIO MAX. 

10m 

RS485 

Total cable length 100m or less. 

Cable Length 

Fieldbus 

Refer to each Fieldbus specification 

Data Setting and Input 

PC Software, Touch Panel Teaching, Teaching Pendant, Data Setter 

Data Retention Memory 

C                 

 

: Saves position data and parameters to non-volatile 

memory (There is 100,000 times in number of 

writing) 

CA/CB/CGB: Saves position data and parameters to non-volatile 

memory (There is no limitation in number of writing)

Saves position data 

and parameters to 

non-volatile memory 

(There is no limitation 

in number of writing)

Number of Positions 

768 points (Changing on the selection in operation mode) 

Feedback Pulse 

(Dedicated for Servo Press 

Specifications) 

CB/CGB Type : Differential System (Line Driver System)   

MAX. 2.5Mpps 

Common 

: Open Collector Type 500Kpps max. (under 

condition JM-08 is used) 

 
 
 
 

SCON-C/CA/CB/CGB 

Item 

Less than 400W 

400 to 750W 

3000 to 3300W 

SCON-CAL/CGAL

LED Display   

(mounted on Front Panel) 

PWR (green)  : Controller in normal condition,   

SV (green) 

: Servo ON,   

ALM (orange) : Alarm generated,   

EMG (red) 

: Emergency Stop,   

WRG (orange): Warning generated (only CAL/CGAL Type) 

Electromagnetic Brake Compulsory 

Release Switch (mounted on Front Panel)  Switching NOM (standard)/BK RLS (compulsory release) 
Insulation Resistance 

500V DC    10M

Ω

 or more 

Insulation Strength 

1,500V AC for 1 min.    (Note) Withstand voltage of force control loadcell is 50V DC 

Surrounding Air Temperature 

0 to 40

°

Surrounding Humidity 

85%RH or less (non-condensing) 

Surrounding Environment 

[Refer to Installation Environment] 

Surrounding Storage Temperature  -20 to 70°C (non-condensing) 
Surrounding Storage Humidity 

85% or less (non-condensing) 

Envi

ro

nm

ent 

Vibration Durability 

XYZ Each direction 10 to 57Hz Pulsating amplitude 0.035mm (continuous) 
0.075mm (intermittent) 

57 to 150Hz 4.9m/s

2

 (continuous)  9.8m/s

2

 (intermittent) 

Mass 

SCON-C:  
Approx. 800g 
SCON-CA/CB/CGB: 
Approx. 900g 

SCON-C:  
Approx. 1000g 
SCON-CA/CB/CGB: 
Approx. 1200g 

Approx. 2800g 

Approx. 560g 

Cooling Method 

Natural air-cooling 

Forced Air Cooling 

Forced Air Cooling 

Forced Air Cooling 

External Dimensions [mm] 

58W 

×

 194H 

×

 121D  72W 

×

 194H 

×

 121D 92.7W 

×

 300H 

×

 187.7D 49W 

×

 158H 

×

 116D

 

Power Capacity and Heat Generation 

Rated Power Capacity 

=

 Motor Power Capacity 

+

 Control Power Capacity 

Peek Max. Power Capacity 

=

 Peek Max. Motor Power Capacity 

+

 Control Power Capacity 

Actuator Motor Type 

Motor Power 

Capacity 

[VA] 

Peek Max. 

Motor Power 

Capacity [VA] 

Control Power 

Capacity 

[VA] 

Rated Power 

Capacity 

[VA] 

Peek Max. 

Power Capacity 

[VA] 

Heat 

Generation 

[W] 

12 

41 123 

89 171 30 

20 

26  78 

74 126 30 

30D 

(Excluding 

RS) 

46 138 

94 186 31 

30R (for RS) 

138 

414 

186 

462 

33 

60 

138 414 

186 462  33 

60 

(RCS3-CTZ5) 

197 591 

245 639  32 

100  234 702 

282 750  35 

100S 

(LSA) 

283 851 

331 899  36 

150 328 

984 

376 

1032 

37 

200 421 

1263 

469 

1311 

38 

200(DD)  503 1509 

551 1557  7.5 

200S 

(LSA excluding LSA-N15H) 

486 1458 

534 1506  38 

200S 

(LSA-N15H) 

773 2319 

821 2367  56 

300S 

(LSA) 662 1986 

710 2034  40 

400 

920 2760 

968 2808  45 

400 

(RCS3-CT8) 

1230 3690 

1278 3738  47 

600 1164 

2328 

1212 

2376 

56 

600 

(DD) 1462 4386 

1510 4434  20.8 

750 3042 

3090 

750S 

1521 

4563 

1569 

4611 

58 

3000 5657 

16970 

5705 

17018 

180 

3300 6014 

18041 

48 

6062 18099  182 

RS : Rotary Shaft      LSA : Linear Actuator      DD : Direct Drive Motor 

 

Selection of Circuit Interrupter 

• 

3 times of the rated current may flow to the controller during the acceleration/deceleration. Select an interrupter that 
does not trip with this value of current. If a trip occurs, select an interrupter that possesses the rated current of one 
grade higher. (Refer to the operation characteristics curves in the product catalog.) 

• 

Select an interrupter that does not trip with the in-rush current. (Refer to the operation characteristics curves in the 
product catalog.) 

• 

Consider the current that enables to cutoff the current even when a short circuit current is flown for the rated cutoff 
current. 
Rated Interrupting Current 

>

 Short Circuit Current 

=

 Primary Power Capacity / Power Voltage 

Consider margin for the rated current on the circuit breaker. 

 

 For ~750W Motor 

Rated Current for Circuit Interrupter 

>

 (Rated Motor Power Capacity [VA] 

+

 Control Power Capacity [VA]) / AC Input Voltage

×

 Safety Margin (reference 1.2 to 1.4 times)

 

 

 For 3000~3300W Motor 

Rated Current for Circuit Interrupter 

>

 (Rated Motor Power Capacity [VA] 

+

 Control Power Capacity [VA]) / AC Input Voltage

×

 Safety Margin (reference 1.2 to 1.4 times) / 

3

 

 

External Dimensions

 

SCON-C/CA/CB/CGB (For ~750W Motor) 

Less than 400W 

     400 to 750W 

 
 
 
 
 
 
 
 
 
 
 

 
 

Applicable to Fieldbus

Model

Serial number

In Absolute Battery Attachment
(Absolute Encoder Type)

In Absolute Battery Attachment
(Absolute Encoder Type)

Side View (Common)

Warning :  Operation of this equipment requires detailed installation and operation instructions which are 

provided on the DVD Manual included in the box this device was packaged in. It should be retained 

with this device at all times. 

 

A hardcopy of the Manual can be requested by contacting your nearest IAI Sales Office listed at   

the back cover of the Instruction Manual or on the First Step Guide. 

S C O N - C A - 2 0   I   H A - N P - 3 - 1 - D N - * *  

<Series> 

 

<Type> 

:  Standard Type 

CA 

: High Performance Type 

CB : 

High 

Performance 

Type 

CGB  : Safety Category Compliant Type   
CAL : Small Type  CGAL: Safety Category Compliant Type 

 

<Actuator Characteristics> 
    [Motor Type] * For SCON- CAL/CGAL, 200W or Less 

12 

: 12W   

200S  : 200W (LSA) 

 

20 

: 20W 

300S  : 300W (LSA) 

30D  : 30W (Excluding RS)   

400  : 400W 

30R  : 30W (for RS)   

600  : 600W 

60 

: 60W 

750  : 750W 

100  : 100W 

750S  : Equipped with loadcel 

100S : 100W (LSA)   

 

  RCS2-RA13R l 

150  : 150W                  3000

 

: 3000W 

200  : 200W                  3300 : 3300W 

 

<Encoder Type> 

I : Incremental    A : Absolute    G : Spurious Absolute

(Note 1) 

WAI : Battery-less Absolute (Incremental) 

(Note 3)

 

 

<Option> 

No Indication : Standard Type     

I  : Index Absolute Type (DD)

 (Note 1)

 

HA : High Acceleration/Deceleration Type   

M  : Multi-Rotation Absolute Type (DD)

 (Note 1) 

F : 

Servo 

Pressing 

Type

 

(dedicated for servo press actuators) 

<Identification for IAI use only> 
* There is no identification in some cases. 

 

<Type of Installation (dedicated for SCON-CAL/CGAL)>

Not Specified : Screw Attachment Type 
DN : DIN Rail Mounting Type 

 

<Power-supply Voltage> 

1 : Single-Phase 100V AC 
2 : Single-Phase 200V AC 
3 : Three-Phase 200V AC 

 

<I/O Cable Length> 

0 : Equipped with no cable 2 

2m 

3 : 3m (Standard) 

5 : 5m 

<I/O Type> 

NP : NPN Specification (Sink Type) (Standard)  ML  :  MECHATROLINK-

/

 Connection Type

(Note 2)

   

PN : PNP Specification (Source Type)   

ML3 :  MECHATROLINK Connection-

(Motion) Type

(Note 1)

 

DV : DeviceNet Connection Type 

EC  :  EtherCAT Connection Type 

(Note 2)

 

CC : CC-Link Connection Type 

EP  :  EtherNet/IP Connection Type 

(Note 2)

 

PR : PROFIBUS-DP Connection Type 

PRT :  PROFINET-IO Connection Type 

(Note 2)

 

CN :  CompoNet Connection Type 

(Note 2)

   

CIE  :  CC-Link IE Connection Type 

(Note 3)

 

 

(Note 1) Specified only for SCON-CA/CB/CGB   
(Note 2) Except for SCON-C 
(Note 3) Specified only for SCON-CB/CGB 

DeviceNet Connector

 

CA/CB/C Type 

CAL Type

 

   

 

CC-Link Connector

 

CA/CB Type 

CAL Type 

C Type

 

   

   

DA DB DG SLD 

FG 

CC-Link Terminal Resistance

 

 

Connector for Multi Function

 

 

System I/O Plug 

~750W Motor  3000W~Motor 

 

 

AC Power Supply Plug 

~750W Motor  3000W~Motor

 

 

 

Brake Power 

Supply Plug

 

 

Absolute Battery 

 

 

Regenerative Resistor Unit 
Connecting Plug

 

3000W~Motor

 

 

Summary of Contents for SCON-CGAL

Page 1: ...ieldbus Refer to each Fieldbus specification Data Setting and Input PC Software Touch Panel Teaching Teaching Pendant Data Setter Data Retention Memory C Saves position data and parameters to non volatile memory There is 100 000 times in number of writing CA CB CGB Saves position data and parameters to non volatile memory There is no limitation in number of writing Saves position data and paramete...

Page 2: ...is used by connecting to the actuator corresponding to the force control or servo press Specification Item Specification Loadcell System Strain Gauge Rated Capacity N 200 600 2000 6000 20000 30000 50000 Allowable Overload R C 1 200 200 200 200 200 200 Loadcell Accuracy R C 1 1 1 1 Applicable Temperature Range C 0 to 40 1 R C Rated Capacity Refer to each actuator instruction manual for details of h...

Page 3: ...unted inside the controller Note 3 It is the contact output to control the drive source breaker connected externally The rating is 30V DC and 20mA or less Note 4 Connect a temperature sensor when an external regenerative resistor unit is connected Operation Modes and Functions other than MECHATROLINK Ⅲ Note Refer to the Section for MECHATROLINK Ⅲ for the operation modes and features of MECHATROLIN...

Page 4: ...e master setting Note Make sure to reboot the controller after the parameter setting is complete and do not forget to turn the mode changeover switch to AUTO side Operation Mode Setting and Address Assignment Please refer to the Instruction Manual for CompoNet ME0220 It is no enclosed in terminal resistor It is unnecessary to supply the communication power to SCON for CompoNet Type However connect...

Page 5: ...ctor on Controller side L ER LINK L ER LINK Master Unit Slave Devices SCON CC Link IE Type Ethernet Straight Cable Category 5e or more Double shielded cable braided with aluminum foil recommended Note Terminal resistance is not required There is no distinction of IN OUT on the connector No No Yes No Check the emergency stop circuit No Yes Yes Yes Yes Check of Packed Items Are there all the deliver...

Reviews: