Rack Installation Instructions

Review the documentation that comes with your rack cabinet for safety and cabling information. When
installing your server in a rack cabinet, consider the following:

Two or more people are required to install the device in a rack cabinet.

You must have a NetBAY

25, NetBAY42, NetBAY42 Enterprise, NetBAY22 with Rack Extension Kit,

Netfinity

 9306 Model 900 with Rack Extension Kit, or similar rack cabinet.

Ensure the room air temperature is below 35°C (95°F).

Do not block any air vents, usually 15 cm (6 in.) of air space provides proper airflow.

Plan the device installation starting from the bottom of the rack cabinet.

Install the heaviest device in the bottom of the rack cabinet.

Do not extend more than one device out of the rack cabinet at the same time.

Remove the rack doors and side panels to provide easier access during installation.

Connect all power cords to properly wired and grounded electrical outlets.

Take precaution to prevent overloading the power outlets when you install multiple devices in a rack
cabinet.

You will need a flat-blade and a Phillips screwdriver during the installation. The following illustration
shows the items that you need to install the server in your rack cabinet. If any items are missing or
damaged, contact your place of purchase.

M4 screw

(10)

M3.5 thumbscrew

(1)

slide rail

(2)

(1)

cage-nut-insertion

tool

M6 screw

(16)

clip nut

(16)

cage nut

(16)

cable strap

(6)

cable-management

assembly

(1)

cable clamp

(10)

cable management

arm hinge plate

(1)

Chassis
support bracket (1)

Use safe practices when lifting.

18 kg (39.7 lb)

32 kg (70.5 lb)

55 kg (121.2 lb)

Do not place any object weighing more than
50 kg (110 lb) on top of rack-mounted
devices.

>

50 kg (110 lb)

   

 

1

Summary of Contents for System X Series

Page 1: ...the rack cabinet at the same time Remove the rack doors and side panels to provide easier access during installation Connect all power cords to properly wired and grounded electrical outlets Take precaution to prevent overloading the power outlets when you install multiple devices in a rack cabinet You will need a flat blade and a Phillips screwdriver during the installation The following illustra...

Page 2: ...rail to align the slide rail to the rear mounting flanges If the front slide rail bracket does not align with the front mounting flange slightly loosen the rail length adjusting screws 2 and adjust the length of the rail 4 Install the slide rails ensuring that the front and rear slide rail brackets for both slide rails are vertically aligned Insert and partially tighten the four rear M6 screws 1 t...

Page 3: ... safe place Also remove the blue thumbscrew 3 from the left side of the server and store it in a safe place Note The rack support wheels and the handles are required if you remove the server from the rack cabinet You must also install the blue thumbscrew if you intend to remove the server from the rack cabinet and move the server to a new location 7 Insert the tab on the bottom edge of the cable m...

Page 4: ...pring loaded hinge pins 2 then rotate the handles to lock the pins in the retracted position 11 Slide the tab 1 on the cable management arm into the slot 2 in the hinge plate then release the hinge pins into the holes in the plate 12 Attach cables to the rear of the server such as keyboard mouse and monitor cables if required Route the cables toward the left side of the server Use cable clamps to ...

Page 5: ...ace Note If you move the rack cabinet or install it in a vibration prone area insert the M6 screws 2 then install the chassis support bracket see Step 15 If the server comes installed in the rack cabinet the bracket also comes installed and need not be removed 15 Important The chassis support bracket must be installed if you move the rack cabinet after you install the server Align the bracket 2 so...

Page 6: ...tries or both Copyright 2002 International Business Machines Corporation All rights reserved Note to U S Government Users Documentation related to restricted rights Use duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corp Part Number 02R2725 Printed in U S A 1P02R2725 6 ...

Reviews: