User  Manual

…  to  make  people  listen

Audio  Matrix  EV-5000

Summary of Contents for EV-5000

Page 1: ...ic audio Status 11 2009 User Manual to make people listen Audio Matrix EV 5000 ...

Page 2: ...ic audio EV 5000 EN 2 ic audio 1 Images Front View Rear View ...

Page 3: ... Matrix Power Amplifiers Digital Control Line Relays Line Monitoring EV 5000 Central Unit CH1 OUT CH2 OUT CH3 OUT CH4 OUT SPARE AMP IN OUT Spare Amp OUT CH1 OUT CH2 OUT CH3 OUT CH4 2x Alarm Switch IN Error System Emergency Alarm Relay contacts Message control IN AUX IN Request 230 V AC 24V DC Backup supply Cascade RS 232 Fire MIC2 Matrix Control AMP IN AMP IN AMP IN AMP IN Chime control IN MIC con...

Page 4: ...ive on any errors Background Music Start Chime momentary switch Start stored message momentary switch Start stored Emergency announcement 1 Start stored Emergency announcement 2 EV EVAC1 EV P4 EV P4 EV PAGE EV PAGE Further EV 5000 Personal Computer for simple configuration overview Power Amplifiers 24V DC Backup Power IN Fire MIC 1 Fire MIC 2 IN on front panel FIRE MIC EV 5000 80 Channel MIC Bus O...

Page 5: ...p the System 14 11 Programming the central unit EV 5000 14 12 Special Setups 18 13 Functions when connecting a PC 19 14 Deleting Error Messages 22 15 Priorities 23 16 Sound file card 23 17 EV PAGE 80 Channel Callstation 25 18 EV P4 Subzone Callstation 26 19 EV EVAC 1 Fireman Desktop Microphone 26 20 EV EVAC MIC Fireman Handheld Microphone 26 21 EV REL Relay Card 27 22 Sample Setups 33 23 Technical...

Page 6: ...lly set up for an AC line voltage of 230 volts 50 to 60 Hz The unit may only be operated at a power receptacle with protective earth conductor The wires of the mains power cord have the following colours GREEN and YELLOW PE Protective Earth BLUE N Neutral BROWN L Live Warning The protective earth conductor must never be interrupted even for test purposes This may be dangerous to life Do not block ...

Page 7: ...arm Matrix which operates all necessary supervisionfunctions in a slim 1 unit housing according to EN 60849 You can connect several callstations and release emergency announcements stored evacuation signals chimes and background muisc All sound files are stored on a SD Flash Memory card for easy handling The EV 5000 is the smart choice for a wide range of applications such as schools convenience s...

Page 8: ...ireman callstations one on rearside and one on front panel Mic capsules and control wires are monitored u 1 Line input for instance for background music with separate level control for each output u 1 Line input AUX with contact activating for instance for spotplayer with separate level control for each output u 2 supervised emergency announcements EMY with contact activating u 1 stored message MS...

Page 9: ... jumpers 8 2 EV PAGE System callstation to address up to 80 zones emergency announcement EMY1 can be started 8 3 EV P4 Subzone callstation to address up to 4 zones 8 4 EV EVAC 1 Fireman desktop microphone monitored 1x all call 8 5 EV EVAC MIC Fireman handheld MIC monitored 1x all call 8 6 EV REL Relay card for zone expansion ...

Page 10: ...llowing drawing shows some wiring for balanced and unbalanced amplifier inputs These samples are valid for amplifiers which are earthed by a 3 pole mains power cord and plug If all insulated double isolation 2 pole mains power plug amplfiers are used which have also no GND connection via a backup power supply the shield must be connected on the EV 5000 side GND screw terminal too The amplifier out...

Page 11: ...n parallel The RJ45 pin layout is also the same as the screw terminals 1 15V DC 2 GND 0V 15V 3 RS485 4 RS 485 5 GND 6 EVAC 7 Capsule CAP hot 8 Capsule CAP cold Maximum cable run is 200 Meters Only well shielded twisted pair telecommunications cable may be used such as F UTP 4x2x0 8 or CAT5 6 It is possible to extend the cable run up to 500 Meters if the DC power supply normally 15V DC will not dro...

Page 12: ...nit and not to any slave However the EV P4 callstations can be connected to both Master and Slave units and will call to zones connected to each unit only It is not possible to make calls via EV P4 from Slave to Master from Slave to Slave or vice versa Of course EV PAGE can call in all zones If AUX input Message and Chime for breaks should be started in all systems at a time the control contacts a...

Page 13: ... 93C86 EEPROM on socket see stripy IC on Slave image Language EEPROMs are available from ic audio 9 10 Port for Personal Computer A RS232 port is provided to connect a PC For getting started no PC is necessary but it will provide for a quick and comfortable overview of all parameters and helps keeping records ...

Page 14: ... automatically be switched in place of the defective operational amplifier both input and output When not starting the installation run no monitoring will take place and some of the system components will not function To stop sounding the siren press the PROGRAM key then key T2 reset and after that key T1 siren OFF After having repaired the defective amplifier a reset has to be made In order to do...

Page 15: ...en line alarm start impedance tolerance measuring mode n T2 volume adjustment n T3 installing all connected components installation run n T4 programming the audio outputs going to amplifiers and the line relays T1 selects a sub menu the display shows By pressing key T2 the preannouncement chime can be switched ON and OFF After pressing T1 on the display appears After pressing T2 appears By pressin...

Page 16: ...e of impedance measuring Pressing T1 once agin appears T1 switches the AUX input without using the request control line permanently active This function is very useful for testing voice intelligibility To stop this mode push the PROGRAM key whereon the system returns to the opening menu T2 switches back directly to the opening menu T2 Adjustment of all volume controls Besides the items shown in th...

Page 17: ...ears Here it is defined which of the 4 line relays are activated Caution In a standard configuration as shown on page 4 the line relays have to be cleared no numbers set This will continue backgroundmusic on the not adressed zones during an announcement In the following special examples 12 1 and 12 2 programming has to be done different according to the requirements of these configurations Because...

Page 18: ...s audio has to be deactivated Energise relays 2 and 4 as a call goes to zone 3 As already mentioned relays have to be activated which must switch OFF zones In principle the same is valid for emergency announcements or inhouse messages MSG for instance During a call switched OFF zone speaker lines were connected to the backup amplifier by the line relays The backup amplifier provides for the check ...

Page 19: ...adjustments without checking all menus and submenus with the exception of item 5 and 7 below Therefore no special software is needed a simple terminal software such as Windows Hyperterminal will do First a PC COM port is to be connected to the RS232 port of the EV 5000 via a null modem cable reversed Start the terminal software and ajust the following parameters Bits per second 9600 Data bits 8 Pa...

Page 20: ...INSTALLED PAGE P8 2 3 AMP 1 LINE 1 030 032 AMP 2 LINE 2 038 035 AMP 3 LINE 3 036 033 AMP 4 LINE 4 035 036 SPARE AMP INSTALLED BATT VOLTAGE 24V LEVEL ZONE1 ZONE2 ZONE3 ZONE4 MUSIC 06 dB 06 dB 06 dB 06 dB MUSIC MA 12 dB 12 dB 12 dB 12 dB CHIME 16 dB 16 dB 16 dB 16 dB MESSAGE 06 dB 06 dB 06 dB 06 dB AUX 06 dB 06 dB 06 dB 06 dB VOLUME 10 dB 10 dB 10 dB 10 dB BASS 00 dB 00 dB 00 dB 00 dB TREBLE 00 dB 0...

Page 21: ...ters maximum for instance the following appears SOURCE L1 L2 L3 L4 R1 R2 R3 R4 EV P2 4 01 EV P2 4 02 EV P2 4 03 EV P2 4 04 ALARM 1 ALARM 2 MESSAGE CHIME AUX FIRE MIC1 FIRE MIC2 PAGE P8 GC PAGE P8 01 PAGE P8 02 PAGE P8 03 PAGE P8 04 CHIME ON MUSIC ON SHORT TO EARTH 4I3I2I1I IMPEDANCE 4I3I2I1I SHORT CIRCUIT 4I3I2I1I OPEN LINE 4I3I2I1I SWITCH1 4 ALARM1 4 NORMAL 007 TEXT INPUT LINE 1 KEY 1 LINE 2 KEY ...

Page 22: ...ter key factory settings delivery status were loaded Alle user settings are deleted 14 Deleting stored Error Messages Please perform one of the following procedures to delete all stored error messages 1 Start an installation run after entering the password or 2 Load factory settings This can only be done by connecting a PC starting the terminal software and then pushing key 7 LINE 1 008 000 000 OK...

Page 23: ...tatus which is indicated by a quickly flashing busy LED in EV P4 and by showing BUSY in the EV PAGEs display An EV P4 sub zone call station connected to a slave unit can make calls in its slave system at the same time as another EV P4 on a master unit shall do There is no interference one to another 16 Soundfile Card All sound files are stored on a SD card inside the device The system can play MP3...

Page 24: ...te After reinserting the SD card into the EV 5000 the sequence can be checked by pressing the PROGRAM key and then T4 The file numbers and the file names are displayed one after another The file names may contain up to 8 characters The 16 kHz test tone has to be placed first and as original sound file on the card it is stored also first on the card on delivery Each of the 6 above mentioned storage...

Page 25: ...is moved and by key ALARM the menu is left When leaving all entries are stored automatically To enter texts the numeric keys are multiple used characters can be chosen by several pushing a key Key 4 allows for allocating an address to the call station Addresses can be selected in the range of 00 to 08 If 00 ist assigned the ALARM key has no function whereas the addresses 01 to 08 will unblock the ...

Page 26: ...ation is ready to use Quickly flashing indicates that a preannouncement chime an emergency announcement or a message is just running as well as another call station is active or the AUX input is requested An active fireman call station is indicated by continuous lighting The busy signalling has to be observed to avoid two persons talking at a time since the EV P4 have no priority function among ea...

Page 27: ... controlled by the 80 channel MIC bus of a EV 5000 Master and or 5 control contacts For easily inserting into a call station bus 2 parallel RJ45 sockets are available Each relay can be programmed by means of DIP switches By switching speaker lines in inverse mode the supervising functions from Master Slave units will be maintained Power has to be supplied by an external 24V DC source for instance ...

Page 28: ...6 D5 D4 D3 D2 D1 ON ON D8 D7 D6 D5 D4 D3 D2 D1 ON ON D8 D7 D6 D5 D4 D3 D2 D1 ON ON ON ON ON DECODER 1 DECODER 2 DECODER 3 DECODER 4 DECODER GLOBAL SWITCH MATRIX SWITCH MATRIX SWITCH MATRIX SWITCH MATRIX RELAYS 1 2 3 4 80 CH MIC BUS IN OUT T1 T2 T3 T4 PRIO 24V DC IN SWITCH CONTACT INPUTS R1 R2 R3 R4 R1 R2 R3 R4 R1 R2 R3 R4 R1 R2 R3 R4 R1 R2 R3 R4 R1 R2 R3 R4 R1 R2 R3 R4 R1 R2 R3 R4 ...

Page 29: ...ed in the adjacent sample these are relays R1 R3 and R4 As already explained for inverse function of line relays control the not active lines have to be switched So in this example the message will only be heard in the zone which is connected to relay 2 Attention The global decoder has to be set to address AAH as the EV REL is used for extending the number of zones in inverse programming mode see ...

Page 30: ...he global decoder has no switch matrix its output will always energise all 4 relays at the same time In addition to the 80 channel bus in normal mode the inputs of the contact switch matrix T1 to T4 and PRIO can be used These inputs can be connected to the switch outputs of the EV P4 subzone call stations for instance Each of the 5 inputs is to be routed via a 4 pole DIP switch to the 4 relays The...

Page 31: ...145 91H 1001 0001 front side DIN connector AUX 81 51H 0101 0001 Message MSG 152 98H 1001 1000 Code for selecting inverse programming mode to supervise speaker lines for global decoder only Inverse Mode 170 AAH 1010 1010 Set this code at the global decoder for using EV REL to extend the number of speaker lines in an EV 5000 system ON D8 D7 D6 D5 D4 D3 D2 D1 ON D8 D7 D6 D5 D4 D3 D2 D1 ON D8 D7 D6 D5...

Page 32: ...D5 D4 D3 D2 D1 Function Dezimal Hex Code Binary Code DIP Switch Codes for decoder 1 to 4 as well as for global decoder EV PAGE global acts on Single Call Group Call and All all 82 52H 0101 0010 Alarm 1 2 Fire MIC 1 2 83 53H 0101 0011 Alarm 1 2 84 54H 0101 0100 Fire MIC 1 2 85 55H 0101 0101 EV PAGE global Fire MIC 1 2 86 56H 0101 0110 Alarm 1 2 ...

Page 33: ...nput with contact activating request 1 stored message 1 chime for breaks 1 program backgroundmusic input Maximum 4 zones without EV REL relay card EV 5000 EV P4 RAC 02 CD MP3 Background music AMP 480 CH 1 OUT CH 2 OUT CH 3 OUT CH 4 OUT AMP 480 AMP 480 AMP 480 Audio in 100V Line Speaker line 1 100V Speaker line 2 100V Speaker line 3 100V Speaker line 4 100V Audio in 100V Line Audio in 100V Line Aud...

Page 34: ...one zone is addressed The reason for this is that one amplifier cannot transmit two different signals Call and BGM at a time Of course this is not valid for the remaining three zones of the EV 5000 to which no EV RELs are connected Attention should be paid to the fact that EV P4 subzone callstations will not work together with EV REL AMP 480 CH 1 OUT EV REL Speaker Line 1 4 100V 100V Line Out 80 C...

Page 35: ... 1 chime for breaks 1 program backgroundmusic input The preceding additional Slave sources can only be used in the respective Slave unit They cannot be routed to another Slave or to the Master unit Up to 30 EV P4 per Slave the Master can have also up to 30 EV P4 simultaneously EV PAGE and EV EVAC have to be connected to the Master unit only AMP 480 EV 5000 Master EV EVAC 1 CH 1 OUT Backup amplifie...

Page 36: ... valid as mentioned in chapter 22 2 AMP 480 EV 5000 Master EV EVAC 1 CH 1 OUT Backup amplifier EV PAGE Audio in 100V Line EV REL 1 DIN connector LINE Speaker line 1 4 100V EV REL Speaker line 5 8 100V 2 EV REL Speaker line 9 12 100V 3 AMP 480 CH 4 OUT AMP 480 CH 2 OUT AMP 480 CH 3 OUT EV REL 4 Speaker line 13 16 100V AMP 480 CH 1 OUT Audio in 100V Linie Speaker line 17 20 100V Backup amplifier AMP...

Page 37: ...M to outputs for amps 0 dBu 0 05 6 dBu 0 05 10 dBu 1 MIC inputs 0 dBu 0 35 6 dBu 0 7 10 dBu 1 Signal to Noise ratio BGM IN MIC IN 46 dBu 600 Ohm 78 dB 50 dB Check Tone frequency 22 kHz Check Tone MIC capsule 1 kHz 100V switch relays switching voltage 160 V AC max switching current 8 A AC Pmax 800 Watts Miscellaneus relay contacts 120 V AC max 2 A AC max Display blue two line alpha numeric LCD disp...

Page 38: ...e of display indication German or English alterable by exchanging the CPU Operating voltage 15 V 1V DC via bus Current drain 50 mA idle 90 mA max Dimensions W x D x H 140 x 193 x 25 60 mm front rear Length of gooseneck 420 mm capsule included Connecting cable 3 Meters 2x RJ45 Weight 1 2 kg Colour aluminium natural anodised side frames blue 22 3 EV EVAC 1 Microphone type Dynamic capsule on goosenec...

Page 39: ... mV Pa 1 kHz Frequency response 150 Hz 12 kHz Audio output unbalanced MIC level Number of addressable zones 1 All Call Control output Key contact feed cable monitored Connecting cable 0 4 m Meter helix cable fixed on handheld MIC other end 5 pole DIN connector DIN 41524 Dimensions W x H x D 50 x 100 x 45 mm Weight 0 15 kg Colour red 22 5 EV P4 MIC type Dynamic capsule 600 Ohms on gooseneck Sensivi...

Page 40: ...d to be built in a housing or a rack Connections 2x RJ45 socket for 80 channel call station bus 6 screw terminals for control contacts 2 screw terminals for 24 V DC supply 4x 6 pole screw terminals for relay contacts Operating voltage 24V DC Current drain 160 mA max 40 mA idle Relay switch power 160 V AC 8A Pmax 800 Watts per zone Dimensions W x D x H 199 x 85 x 30 mm Weight 0 3 kg Temperature ran...

Page 41: ...ic audio to make people listen ic audio GmbH Boehringerstraße 14a D 68307 Mannheim Germany Fon 49 0 621 77096 0 Fax 49 0 621 77096 26 www ic audio com E Mail info ic audio com ...