Console Water Source Heat Pump (WSHP)

OPERATING & MAINTENANCE MANUAL

World class comfort.

Summary of Contents for Console Water Source Heat Pump

Page 1: ...Console Water Source Heat Pump WSHP OPERATING MAINTENANCE MANUAL World class comfort ...

Page 2: ... 14 1 4 SECTION G G SCALE 1 10 HOLE FOR DRAIN HOSE JUNCTION BOX FRONT VIEW NOTES DIMENSIONS ARE SHOWN IN INCHES 1 OPTIONAL MOTORIZED WATER VALVE IS SHOWN 2 ALL DIMENSIONS ARE 1 4 3 LEFT HAND CONFIGURATION IS SHOWN 4 UNIT IS SHIPPED WITH UNIVERSAL LEFT HAND OR RIGHT HAND 5 PIPING CAPABILITY 6 OPTIONAL OUTSIDE AIR DOOR SHOWN 7 SUPPLY AND RETURN PIPES HAVE 1 2 THREADED FEMALE ADAPTER A B C D E 5HPW09...

Page 3: ...ed in a separate instruction sheet specific to that option On behalf of ICE AIR and our network of distributors and dealers we are happy to welcome you to our base of satisfied customers CONSUMER SAFETY AND OPERATING NOTES FOR SAFE AND OPTIMAL ENJOYMENT OF YOUR ICE AIR WSHP UNIT PLEASE READ THE FOLLOWING CONSUMER SAFETY AND OPERATING NOTES CAREFULLY BEFORE OPERATING YOUR EQUIPMENT This unit MUST b...

Page 4: ...circuit breaker for branch circuit overcurrent protection Consult the unit serial plate for current ratings All 208 230V units are wired for 208V operation unless otherwise specified The following physical conditions must be maintained for proper unit operation Unobstructed air flow into and out of the unit room enclosure cabinet Therefore Do not place furniture rugs or objects directly in front o...

Page 5: ...Power Control Board PCB The large LCD display panel includes clearly marked control buttons The Control pad is a programmable user friendly device that enables the user to program desired temperature settings and operational modes LCD Programmable Thermostat Feature list Operates on 2 stage Heat and 2 stage Cool 7 programs Mo Tu We Th Fr Sa Su or 5 2 programs Mo Fr Sa Su 4 Separate Time and Temper...

Page 6: ...perature The unit will cycle until the set temperature is achieved and then will continuously cycle to maintain the set temperature The temperature reading that is on constant display is the ambient room temperature EVENT TIME HEAT COOL MON FRI WAKE leave return SLEEP 6 00 AM 8 00 AM 6 00 PM 10 00 PM 70º F 21º C 62º F 17º C 70º F 21º C 62º F 17º C 78º F 26º C 85º F 29 5º C 78º F 26º C 82º F 28º C ...

Page 7: ...an when complete The cool limit setting should be at least 4 F higher than the heat limit setting The cool limit setting is 55 F to 95 F The heat limit setting is 51 F to 91 F Exit Internal Setting and Return to Normal Mode 1 Press Fan to confirm and return to normal mode 2 If no key is pressed for 15 seconds it will return to normal mode automatically Temporary Program Override 1 When thermostat ...

Page 8: ...anual assumes that your WSHP unit has been installed by a qualified installation professional and is operating properly prior to maintenance service Have your unit periodically inspected by a properly trained service professional or building maintenance staff person The unit should be checked for the safe and proper functioning of all of its systems at least once a year The following recommended m...

Page 9: ...n a facility properly equipped to handle this type of work in a safe and professional manner Drain Pan Drain Hose Cleaning The condensate pan is located directly under the evaporator coil Check the visible section of the interior of the drain pan for any buildup of dirt or condensate water Wash annually to remove all dirt build up Check condensate drain pan for algae growth every 2 to 3 months If ...

Page 10: ...east once a month Pay special attention to hose assemblies and connections Repair any leaks and replace deteriorated hose immediately to avoid potential costly damage to your property due to component failure TROUBLESHOOTING 1 If unit is not operating conduct the following checks If a flashing A appears on the display contact a trained technician Check the electrical connections Check the voltage ...

Page 11: ...ed Normal Off On Off High Pressure Off Off Flash Low Pressure Flash Off Off Evaporator too cold Flash Off Flash Coaxial winter protection Flash on off Temperature probe failure Off flash Off High low voltage Off Off On Condensate over flow on Off Off Coaxial water too cold on Off flash troubleshooting error code menu ...

Page 12: ...RES MUST BE SERVICED BY QUALIFIED TRAINED PERSONNEL ELECTRIC SHOCK HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING MOVING PARTS HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING UNIT MUST BE OPERATED WITH ALL CHASSIS SHEET METAL PARTS PROPERLY IN PLACE UNIT MUST BE OPERATED WITH ALL ENCLOSURE CABINET PARTS IN PLACE READ THIS ENTIRE OPERATIONS MANUAL BEFORE OPERATING THE U...