background image

User Guide for your Swift 5x

Summary of Contents for Swift 5x

Page 1: ...User Guide for your Swift 5x ...

Page 2: ... Tech Specs Getting Started Setting up your Swift 5x Admin Mode Using and Maintaining your Swift 5x Guidelines for Use Disinfecting Devices Lamp Status Replacement Resetting the Lamp Cycle Counter Troubleshooting Warranty and Registration Customer Support 2 3 4 6 7 8 9 10 12 13 14 15 16 Contents 1 ...

Page 3: ...tion UV light can cause discoloration with continuous exposure to plastic devices that are white or light in color WARNING For the continued protection against risk of fire replace only with fuse of the specified type and current ratings Do not use outdoors or on wet surfaces Use device only as described in this manual Turn off the device before unplugging Any service should be performed by an aut...

Page 4: ... tablets The Swift 5x has been designed for minimal contact with what you place in it allowing maximum surface coverage by germicidal light during the disinfection cycle Please read through this guide thoroughly to ensure proper use of your Swift 5x Meet your Swift 5x About your iCleanse Swift 5x 3 ...

Page 5: ...you are in administrator mode Service Lamps Illuminates when it s time to replace your lamps Stop Button Stops the disinfection cycle Lock Button Locks all trays of the unit The light under this button indicates that the unit is locked Start Button Starts the disinfection cycle for all trays Disinfecting Indicates that the drawer is being disinfected Charging Indicates that a device is being charg...

Page 6: ... of each individual tray Lock Light Indicates when the unit is locked Cycle Time Remaining Progress Bar Disinfection is complete when all lights in the progress bar are no longer lit Numerical Keypad Used to access admin mode change system settings and start an individual disinfection cycle ...

Page 7: ... x 11 in x 75 in 22 cm x 28 cm x 2 cm Disinfection Cycle Time Set at Factory Default is 120 seconds Operating Temp Range 37 F 95 F 2 78 C 35 C Operating Humidity Range 5 95 82 4 F 5 95 28 C Storage Humidity Range 0 95 Non condensing AC Supply Voltage 120VAC 240VAC Installation Requirements Level Surface 3 in 7 5 cm from obstruction Power Cord Length 6 5 ft 2 m ...

Page 8: ...t is on a level surface and has 3 to 4 inches of open space behind it to allow for proper airflow for the cooling fan Plug in the power cord to any standard outlet and power in the unit by using the switch on the back Setting up your Swift 5x ...

Page 9: ... There are two types of PINs stored in the iCleanse s memory administrator PINs and user PINs The unit must be in admin mode to make these changes User PIN Lock and Unlock unit maximum of 16 four digit PINs Administrator PIN Make system changes add and remove users and administrators maximum of 4 four digit PINs Adding and deleting PIN s Add an admin PIN by entering admin mode then entering XXXX a...

Page 10: ... kills germs like pathogenic microorganisms Cleaning vs Disinfecting The iCleanse Swift 5x s germicidal lamps will not penetrate dirt and grime therefore it is highly recommended that you still periodically clean your devices Cleaning is not disinfecting and vice versa Lamp Recycling Please visit www lamprecycle org for information on recycling your lamps after use Expectations Due to the progress...

Page 11: ... The unit will automatically begin charging and disinfecting after 7 seconds once a device is plugged into any of the USB port and all trays are closed You do not have to press the start button if you re charging as well as disinfecting Step 5 The unit automatically locks when the disinfection cycle is in process You will not be able to open the trays or remove devices until the cycle completes St...

Page 12: ... place your device in the basket Step 2 Close the tray Step 3 Repeat steps 1 2 until all devices are in the unit Step 4 Press and hold the start button to disinfect all trays Step 5 The unit automatically locks when the disinfection cycle is in process You will not be able to open the trays or remove devices until the cycle completes Step 6 The cycle is complete when all the DISINFECTING lights ar...

Page 13: ...espan of 4 000 cycles When lamps reach 500 cycles remaining the Service lamps light will turn on When there are 0 cycles remaining you can no longer run a disinfection cycle To learn how to replace your lamps go to www icleanse com support Lamp Status Lamp Replacement ...

Page 14: ... ADMIN MOSE light illuminating on the front panel Step 3 Enter 77 0000 on the keypad Step 4 You should hear a beep and see the SERVICE LAMPS light on the front panel turning off Step 5 Hold and enter 1234 on the keypad Step 6 You will hear a beep along with the ADMIN MODE light on the front panel turning off Step 7 Switch off the unit and turn it back on after 5 seconds Resetting the Lamp Cycle Co...

Page 15: ...bstructions in the bay Close the tray and check that the Tray Open light is off Tray won t close visibly Clear any obstructions If the problem persists contact iCleanse Unit does not power on Check and replace fuses at the power cord connection point Unexpected display or control panel behavior Cycle power switch off on Trays won t unlock Use the default PIN code 1234 Troubleshooting ...

Page 16: ...r product For more info visit www icleanse com warranty Registration Please visit www icleanse com warranty to register your new Swift 5x within 30 days of your purchase to activate your one year warranty Warranty and Registration US Patent Numbers 8296493 8606981 8977796 9254342 10166308 Warranty and Registration ...

Page 17: ...ence team Available Monday thru Friday 9 00am 5 00pm Please keep your model number serial number and purchase date on hand for any future support Model Number Order Number Purchase Date We re Here to Help 800 969 1166 icleanse com support support icleanse com Customer Support ...

Page 18: ...Follow our social media accounts for the most up to date news Connect with Us icleansellc _icleanse _icleanse icleanse icleanse com 2021 17 ...

Reviews: