I-7567 USB/HART 

Converter User’s Manual (Ver 1.3, 2015/10/30) ------------- 1

 

 

User’s Manual 

 
 
 
Warranty  

All products manufactured by ICP DAS are under warranty regarding 

defective materials for a period of one year from the date of delivery to the 
original purchaser. 
 
Warning 

ICP  DAS  assumes  no liability  for  damages  resulting from  the  use  of 

this product. ICP DAS reserves the right to change this manual at any time 
without  notice.  The  information  furnished  by  ICP  DAS  is  believed  to  be 
accurate and reliable. However, no responsibility is assumed by ICP DAS 
for  its  use,  or  for  any  infringements  of  patents  or  other  rights  of  third 
parties resulting from its use. 
 
Copyright 

Copyright 2011 by ICP DAS. All rights are reserved. 
 

Trademark 

The names used for identification only may be registered trademarks 

of their respective companies. 

 I-7567 

USB To HART Converter

 

Summary of Contents for I-7567

Page 1: ...of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is a...

Page 2: ...able Selection 16 3 Driver Installation 17 3 1 Install I 7567 Driver Automatically 17 3 2 Install I 7567 Driver by Manual 18 3 3 Verify Driver Installation 21 3 4 Uninstall I 7567 Driver 22 3 5 Instal...

Page 3: ...ART Converter User s Manual Ver 1 3 2015 10 30 3 Q01 How to use I 7567 to communicate with HART devices 42 Q02 Does I 7567 support the API Library for HART 42 Q03 Can I 7567 work in Win10 42 6 History...

Page 4: ...t be set 1200 bps When connecting I 7567 to PC PC will load the relevant device driver automatically hot plug play Therefore users can make data collection and processing of HART network easier and qu...

Page 5: ...B Type B Compatibility USB 1 1 and 2 0 standard Driver Supported Windows 2000 XP Vista 7 32 64 bit Virtual COM Parameter 1200 bps O odd parity 8 data bit 1 stop bit HART Spec Channel 1 Connector 2 pin...

Page 6: ...ide module configuration and HART communication easily and quickly Provide HART devices search automatically Provide diagnostic Information of HART device Provide data logging for HART communication A...

Page 7: ...I 7567 USB HART Converter User s Manual Ver 1 3 2015 10 30 7 2 Hardware Figure 2 1 Hardware externals of I 7567...

Page 8: ...am Figure 2 2 is a block diagram illustrating the functions on the I 7567 module It provides the 3000Vrms Isolation in the HART interface site VBUS DATA0 DATA0 GND MICROPROCESSOR MCU USB Driver LED mo...

Page 9: ...n Assignment on I 7567 2 2 1 Pin Function Description Pin No Pin Name Pin Function Description 1 N A 2 N A 3 N A 4 HART HART 5 N A 6 N A 7 HART HART 8 N A 9 N A 10 N A 2 2 2 HART Connection The HART c...

Page 10: ...I 7567 USB HART Converter User s Manual Ver 1 3 2015 10 30 10 Ex1 Loop Power Source Internal Resistance Ex2 Loop Power Source External Resistance...

Page 11: ...I 7567 USB HART Converter User s Manual Ver 1 3 2015 10 30 11 Ex3 Loop Power Source External Resistance Ex4 External Power Source Internal Resistance...

Page 12: ...itch is used to provide HART network with 250 1 4 W resistor When it is set to On the resistor will connect to HART network Otherwise it will disconnect the resistor from HART network The default posi...

Page 13: ...ure 2 7 Firmware Operation Figure 2 8 Firmware Updating 2 4 1 Firmware Update Mode Please follow the below steps to complete the firmware update process of I 7567 1 Set the jumper JP1 to the firmware...

Page 14: ...erter i 7567 software 1 Choose USB interface and USB Disk like J 2 Click Browser button to choose FW file like I7567_v1 00 fw 3 Click Firmware Update button to start FW update process The result will...

Page 15: ...0 LED position of I 7567 2 5 1 LED function 1 PWR LED When power on I 7567 if I 7567 is in the firmware operation mode then the PWR LED will be on permanently If I 7567 is in the firmware update mode...

Page 16: ...ble type cable length and terminator in the HART bus network please refer to the following table Note The AWG means a standard method used to measure wire The numbering system works backwards from wha...

Page 17: ...7 Driver Automatically Step 1 Plug in the I 7567 to PC first and Windows will detect the new device and shows the Found New Hardware Wizard screen prompting you to install the driver for the detected...

Page 18: ...ep 1 Please execute icpusbconverter_drvinst_v1 2 exe file first to install necessary driver files of I 7567 to system Step 2 Plug in the I 7567 to PC and Windows will detect the new device and shows t...

Page 19: ...c location Advanced option and click Next button like Figure 3 5 Figure 3 5 New Hardware Wizard 2 Step 4 Please select Search for the best driver in these locations option and check include this locat...

Page 20: ...I 7567 USB HART Converter User s Manual Ver 1 3 2015 10 30 20 Figure 3 6 New Hardware Wizard 3 Step 5 Please click Continue Anyway button like Figure 3 7 Figure 3 7 New Hardware Wizard 4...

Page 21: ...ed successfully then there will be a Virtual COM Port assigned by Windows Please follow the below steps to check it Click Start Settings Control Panel and then double click on the System icon Once the...

Page 22: ...vice driver Step 1 Click Start Settings Control Panel and then double click on the System icon Once the System Properties screen displayed click on Hardware tab and then click on the Device Manager bu...

Page 23: ...Driver 1 Step 2 Click OK button to complete I 7567 device driver un installation like Figure 3 11 After that the ICPDAS I 7567 USB2HART device listing will disappear on Ports COM LPT item Figure 3 11...

Page 24: ...B HART Converter User s Manual Ver 1 3 2015 10 30 24 1 Click the right button of mouse on the I 7567 USB2HART option and choose Update Driver Software 2 Click the Browse my computer for driver softwar...

Page 25: ...I 7567 USB HART Converter User s Manual Ver 1 3 2015 10 30 25 3 Click the Let me pick from a list of device drivers on my computer option 4 Directly click the Next button...

Page 26: ...al Device option and click the Next button 6 Show the Windows has successfully updated your driver software message and it means that I 7567 driver installation is finished 7 In the Device Manager The...

Page 27: ...I 7567 USB HART Converter User s Manual Ver 1 3 2015 10 30 27...

Page 28: ...com pub cd fieldbus_cd hart converter i 7567 software 4 1 Run Utility Run the HC_Tool like Figure 4 1 If users can t run HC_Tool please install NET Framework 3 5 first http www microsoft com downloads...

Page 29: ...ettings The following is the description of HART command fields Auto Configure 1 Enable search HART devices automatically 2 Disable search HART devices according to manual parameters Frame type Select...

Page 30: ...es 4 3 1 Search HART devices automatically Set the option of Auto Configure field to be Enable and the option of Master type field to be Secondary like Figure 4 4 Then HC_Tool utility will automatical...

Page 31: ...can set the HART frame by manual to search HART devices 1 If the option of Frame type field is Short then Master type Preambles Address fields need to be configured like Figure 4 5 Figure 4 5 Short fr...

Page 32: ...ase click the OK button Then users can test the HART communication 4 3 3 Search HART devices 1 Click Open button to open the com port of PC like Figure 4 7 If com port open failed please check the com...

Page 33: ...User s Manual Ver 1 3 2015 10 30 33 Figure 4 8 HART device Information If the error message Search Device Failed shows like Figure 4 9 please check HART network status and HART command format Figure...

Page 34: ...10 Figure 4 10 SRMsg Function 2 Please type the HART command in the Send Data filed and click Send button to send out the HART command like Figure 4 11 1 With Parity Check item When check the item it...

Page 35: ...RT Command 3 When HART device responses the HART information it will show in the Receive Data field like Figure 4 12 If error happened in HART communication it will not show any message in the Receive...

Page 36: ...ommand 4 5 HART Information Log Data Log When using SRMsg or Start function for HART communication all the HART command information will be logged in the Data Log function Users can click Data Log ite...

Page 37: ...Ver 1 3 2015 10 30 37 Figure 4 13 HART Information Log 4 6 HART Configuration HTCfg When HART devices are searched in HC_Tool then users can use HTCfg function to configure HART devices like Figure 4...

Page 38: ...ge Choose the Universal command for configuration Support HART Command version v6 0 4 Common Page Choose the Common Practice for configuration Support HART Command version v6 0 5 Start Button Trig to...

Page 39: ...fg Screen 4 7 Module Configuration ModCfg Click ModCfg item it will show the below two options to open the module configuration screen of HART Converter like Figure 4 16 1 HC_Tool v1 02 or newer suppo...

Page 40: ...le FW Version Return the firmware version of HART converter module 2 Reset Module Reset HART converter module 3 Get HART Send Recv Count Return the total count of the sending and receiving HART messag...

Page 41: ...te parameters of the serial port in I 7570 Figure 4 19 Set Serial Baudrate Function 2 Get Serial Baudrate Get the baudrate parameters of the serial port in I 7570 3 Get Module Info Return the hardware...

Page 42: ...it doesn t If users want to develop their own program to communicate with HART devices please refer to the below suggestion 1 Familiar with HART protocol Using HART Converter like I 7567 I 7570 I 7547...

Page 43: ...Edward 2012 03 02 1 Update content 1 2 Edward 2012 12 20 1 Update FW to v1 5 1 Add Config Function 2 Update HC_Tool to v1 02 1 Add Config screen 2 Add HART v6 0 Universal and Common Practice Command...