background image

TDRS4050601 

1j 

TM

 

ESC  Utility

  User  Manual 

Industrial  Redundant  Ring  Switch 

Version 1.0 

This  document  applied  to  models  of 

  RS-405/405F,  RSM-405/405F 

Mar 28, 2007 
Please print in double side

Summary of Contents for RS-405/405F

Page 1: ...TDRS4050601 1j TM ESC Utility User Manual Industrial Redundant Ring Switch Version 1 0 This document applied to models of RS 405 405F RSM 405 405F Mar 28 2007 Please print in double side...

Page 2: ......

Page 3: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 i Document Control Date Author Version Description Mar 28 th 2007 May Chang 1 0 First draft...

Page 4: ...reproduced stored in a retrieval system or transmitted in any form or by any means whether electronic mechanical photo copying recording or otherwise without the prior written permission of the publis...

Page 5: ...not designed Standards The Ring Switch meets the following standards EMC immunity IEC61326 1 IEEE C37 90 EMI emissions FCC part 15 ICES 003 EN55022 Class B Electrical safety UL 508 CSA C22 14 EN61010...

Page 6: ...cense agreement i Customer Information j Installation Folder k Shortcut Folder l Ready to install the program m Installing the program n Complete Installation o Configuration p Start the Program q Bas...

Page 7: ...Rotary Switch SW2 configuration ccc Power 1 Power 2 Status ddd Alarm Output and Event Log ddd Event Type eee Event Type 1 Power 1 Error fff Event Type 2 Power 2 Error fff Event Type 3 RS 232 RS 485 Co...

Page 8: ...work CSMA CD Acronym for Carrier Sense Multiple Access with Collision Detection Access protocol for Ethernet CSU Acronym for Channel Service Unit a device furnished as an integral part of a digital ac...

Page 9: ...medium FPGA Acronym for Field Programmable Gate Array LAN A local area network is a group of PCs connected over a common medium within a building MAC Acronym for Medium Access Control A designated ha...

Page 10: ...ta circuit terminating equipment employing serial binary data interchange RS 485 Standard defined by EIA aka EIA 485 Standard for electrical characteristics of generators and receivers for use in bala...

Page 11: ...phical user interface program that allows you to configure settings and monitor status for RS 405 series The easy to use GUI design helps reduce learning curve and enables technicians to perform tasks...

Page 12: ...tion via RS232 RS485 Real Time event log monitoring and notification Intended Hardware Product This manual applies to ESC Utility Ver 1 00 in the following products RS 405 5 Port Redundant Ring Switch...

Page 13: ...Redundant Ring Switch RS Series User Manual TDRS4050601 f Before Installing Installation Installation Overview This chapter provides general information you need to know before you start installing E...

Page 14: ...User Manual TDRS4050601 g Before Installing Downloading Updating To get the latest version of this user manual and to download update the latest firmware please go to http www icpdas com Operating Sys...

Page 15: ...to start the Installation Wizard Initial Setup The Installation Wizard will guide you through the installation process It is strongly recommended that you exit all Windows programs before continuing w...

Page 16: ...rial Redundant Ring Switch RS Series User Manual TDRS4050601 i License agreement Please read the license agreement carefully click I accept the terms in the license agreement and then click Next to co...

Page 17: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 j Customer Information Enter your name and company name Then click Next to continue...

Page 18: ...eries User Manual TDRS4050601 k Installation Folder The software will be installed in the folder listed To select a different location either type in a new path or click change to browse for an existi...

Page 19: ...below If you don t want to use the default folder you can either type a new name or select an existing folder from the list If you want to install shortcuts for current user only click Install shortcu...

Page 20: ...S Series User Manual TDRS4050601 m Ready to install the program Click Next to begin the installation If you want to review or change any of your installation settings click Back Click Cancel will exit...

Page 21: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 n Installing the program It may take a few seconds to install this program...

Page 22: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 o Complete Installation To close this wizard click Finish...

Page 23: ...nt Ring Switch RS Series User Manual TDRS4050601 p Start the Program Basic Interface Advanced Interface Configuration Overview This chapter provides information about how to configure an existing devi...

Page 24: ...ute you previously set up for this program I 2 Input the com port 1 for com1 2 for com2 etc 3 Please select the Interface of you preference Basic interface is designed for beginners and Advanced inter...

Page 25: ...Manual TDRS4050601 r Basic Interface Click on tags to go to the following pages Hardware Status and Configuration pages Configuration Page Overview Configuration page displays current settings From h...

Page 26: ...m2 m3 m4 each field contains a value in the range 0 255 The third field in this section GATEWAY IP display current GATEWAY IP address To assign a gateway address for TCP IP please input gateway IP ad...

Page 27: ...e button will appear gray out before you input new values To make the value you input effectively please click on Restart button Note that the Switch Value indicates the value you configure and save o...

Page 28: ...n position and click restart button for port 3 port 4 port 5 please switch SW1 jumper 5 to on position and click restart button Check the square box in front of the port you d like to set relay output...

Page 29: ...mail report setup Note if you make any change of this section you need to click on Save to make new settings effective Log write option Default is autoanalysis mode this will write log every 10 sec Or...

Page 30: ...k on Save to save the new setting Auto email report setup This section allows you to send out auto report by email To enable auto report via email please do the following steps 1 Check Enable auto rep...

Page 31: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 x Disable email report Uncheck Enable auto report via email and click on Save to disable auto report function...

Page 32: ...t the firmware you want to upgrade 5 It may take a few minutes to upgrade firmware Please do not power off or disconnect the device while upgrading the firmware This may cause serious damage 6 After t...

Page 33: ...g values remain intact Advanced Mode Click on Advanced Mode allows you to switch to Advanced Operating Interface Open Log File Click on Open Log File will bring up Real time log viewer that you can re...

Page 34: ...4050601 aa About Utility Click on About Utility will display software information Exit Program Click on Exit Program will exit the program and close the window The system will prompt you if you really...

Page 35: ...Status Indicate RS 232 RS 485 is connected Indicate RS 232 RS 485 is disconnected System time Display current system time Current status Display a message illustrating current status for example When...

Page 36: ...ng Switch RS Series User Manual TDRS4050601 cc Hardware Status Page Overview This page displays information of the hardware features With this integrated and realistic display you can easy monitor cur...

Page 37: ...nformation SW1 is a set of 6 jumpers on the front panel It is a DIP toggle switch with two possible positions on or off Each position indicates one configuration state SW1 DIP Switch Configuration Sta...

Page 38: ...n page for recovery time rtime forward delay ftime maximum age mtime and hello time htime manually If it s on positions other than 0 1 to F a set of preset values will be applied Roteray SW position F...

Page 39: ...ff Power 1 Power 2 Status indicate power is function normally indicate there is a power fail occurring Indicate RS232 RS485 serial connection is connected Indicate RS232 RS485 serial connection is dis...

Page 40: ...will be activated and a warning sign will be shown Communication loss status C Indicate mask is disabled When mask is disabled no mater whether the link status is disconnected or connected no relay ou...

Page 41: ...indicate there is no unusual event Red alarm sign indicate there is unusual event s happening It is recommended to check the error message and solve the problems Event Log record current events You ca...

Page 42: ...ii Advanced Interface Click on tags to go to the following pages Link Status Communication Status Hardware Status and Configuration pages Configuration Page Overview Configuration page displays curre...

Page 43: ...m1 m2 m3 m4 each field contains a value in the range 0 255 The third field in this section GATEWAY IP display current GATEWAY IP address To assign a gateway address for TCP IP please input gateway IP...

Page 44: ...he button will appear gray out before you input new values To make the value you input effectively please click on Restart button Note that the Switch Value indicates the value you configure and save...

Page 45: ...on position and click restart button for port 3 port 4 port 5 please switch SW1 jumper 5 to on position and click restart button Check the square box in front of the port you d like to set relay outpu...

Page 46: ...email report setup Note if you make any change of this section you need to click on Save to make new settings effective Log write option Default is autoanalysis mode this will write log every 10 sec O...

Page 47: ...on Save to save the new setting Auto email report setup This section allows you to send out auto report by email To enable auto report via email please do the following steps 7 Check Enable auto repo...

Page 48: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 oo Disable email report Uncheck Enable auto report via email and click on Save to disable auto report function...

Page 49: ...et the firmware you want to upgrade 5 It may take a few minutes to upgrade firmware Please do not power off or disconnect the device while upgrading the firmware This may cause serious damage 6 After...

Page 50: ...ng values remain intact Advanced Mode Click on Advanced Mode allows you to switch to Advanced Operating Interface Open Log File Click on Open Log File will bring up Real time log viewer that you can r...

Page 51: ...4050601 rr About Utility Click on About Utility will display software information Exit Program Click on Exit Program will exit the program and close the window The system will prompt you if you really...

Page 52: ...Status Indicate RS 232 RS 485 is connected Indicate RS 232 RS 485 is disconnected System time display current system time Current status Display a message illustrating current status for example When...

Page 53: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 tt Link Status Page overview This page displays various information of the link status...

Page 54: ...ant Ring Switch RS Series User Manual TDRS4050601 uu Indicate RS232 RS485 serial connection is connected Indicate RS232 RS485 serial connection is disconnected Indicate the line of the corresponding p...

Page 55: ...t status Link Lose Alarm Mask Status Link Lose Alarm Mask Status indicate current link lose relay output mask setting When the Led is green the mask is enabled and when the Led is grey the mask is dis...

Page 56: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 ww Communication Status Page overview This page displays various information of the communication status...

Page 57: ...square box in front of Show Help will display current Port status Communication Lose Alarm Mask Status Communication Lose Alarm Mask Status indicate current communication lose relay output mask settin...

Page 58: ...1 is enabled Jumper 6 is ON Indicate Ring Pair 2 is enabled Jumper 5 is ON When mask is disabled no mater whether the link status is disconnected or connected no relay output will be activated To act...

Page 59: ...zz To activate relay output for port 3 port 4 or port 5 you will need to enable both mask setting and corresponding ring pair setting Ring Pair 2 When there is a communication loss disconnection occur...

Page 60: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 aaa Hardware Status Page overview This page displays various information of the hardware features...

Page 61: ...information SW1 is a set of 6 jumpers on the front panel It is a DIP toggle switch with two possible positions on or off Each position indicates one configuration state SW1 DIP Switch Configuration St...

Page 62: ...n page for recovery time rtime forward delay ftime maximum age mtime and hello time htime manually If it s on positions other than 0 1 to F a set of preset values will be applied Roteray SW position F...

Page 63: ...urring Alarm Output and Event Log Green alarm sign indicate there is no unusual event Red alarm sign indicate there is unusual event s happening It is recommended to check the error message and solve...

Page 64: ...Error Event Type 7 This switch has been assigned as the master switch Event Type 8 Unknown Error Event Type Overview This chapter describe each event type shows on Event Log Event Type 1 Power 1 Error...

Page 65: ...sconnection of Link or Communication Status detected You will see the warning sign when there is a disconnection Link Status disconnection for Advanced Interface Communication Status disconnection for...

Page 66: ...Industrial Redundant Ring Switch RS Series User Manual TDRS4050601 ggg Event Type 8 Unknown Error An unknown error that the system can t recognize has occurred...

Page 67: ...or Event Type 5 Firmware Error Event Type 6 Power or RS 232 RS 485 Connection Error Troubleshooting Overview This chapter includes some information for general troubleshooting as follows Event Type 1...

Page 68: ...loose or broken power connections Check connections to ensure the power and ground are attached to the correct terminals Check for power loss or power surges at the AC power outlet Check Voltage of p...

Page 69: ...above fails contact support Event Type 5 Firmware Error Check if the firmware is the newest version please go to http www icpdas com download download list htm for downloading newest firmware version...

Page 70: ...ngle phone call On line support HT TP WWW ICPDAS COM T W SEVICES SUPPORT HT M E MAIL SUPPORT ICPDAS COM Contact Worldwide TELEPHONE FAX Taiwan Hsinchu Headquarter 886 3 5973366 886 3 5973733 Banchiao...

Reviews: