SST-2450 Wireless Modem User’s Manual

 

 

 

 

 

 

 

 

 

 

Warranty

 

All products manufactured by ICP DAS are warranted against 
defective materials for a period of one year from the date of delivery 
to the original purchaser. 

 

Warning 

ICP DAS assumes no liability for damages consequent to the use of 
this product. ICP DAS reserves the right to change this manual at 
any time without notice. The information furnished by ICP DAS is 
believed to be accurate and reliable. However, no responsibility is 
assumed by ICP DAS for its use, or for any infringements of patents 
or other rights of third parties resulting from its use. 

 

Copyright

 

Copyright 2002 by ICP DAS. All rights are reserved. 

 

Trademark

 

The names used for identification only may  be registered 
trademarks of their respective companies. 

Summary of Contents for SST-2450

Page 1: ...ges consequent to the use of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable Howev...

Page 2: ...Embedded Controller to 7000 module Using Mode 3 10 4 1 4 Connecting a PC to a PLC Using Mode 3 11 4 1 5 Using the 7188 as a Bridge Using Mode 3 12 4 2 Network communication 13 4 2 1 Application 1 13 4...

Page 3: ...t also in a multi point structure refer to page 13 The SST 2450 is based on a direct sequence spread spectrum and RF technology operating In the ISM bands with a Frequency Range of 2410 496MHz 2471 93...

Page 4: ...mum data transfer rate in asynchronous mode Full duplex mode 9 6Kbps Half duplex mode 28 2Kbps Maximum data transfer rate in synchronous mode Full duplex mode 19 2Kbps Half duplex mode 57 6Kbps Settin...

Page 5: ...03 OMH 030 10 5 3 Product Description 3 1 Pin assignment Radio Modem Frequency Range 2410 2471MHz Channel Space 4 096 Mhz Communication Range 100 300M Interface RS 232 RS 485 SST 2450 SET GND RX TX GN...

Page 6: ...iagram The SST 2450 wave signal cannot pass through metallic obstacles So this product is not suitable for this type of metallic environment The signal can pass thorough a cement wall but will be weak...

Page 7: ...ulates the Full duplex mode The device can transmit and receive signals at the same frequency The RF processor uses the timer controller to simulate Full duplex Initially the module that has been set...

Page 8: ...50 Wireless Modem User s Manual Ver1 5 Feb 2003 OMH 030 10 8 4 1 1 PC to PC connections Using Mode 1 Full Duplex Asynchronous Master Baudrate 9600bps Max Full Duplex Asynchronous Slave Baudrate 9600bp...

Page 9: ...less Modem User s Manual Ver1 5 Feb 2003 OMH 030 10 9 4 1 2 Connecting a PC to the 7000 module Using Mode 2 Full Duplex Synchronous Master Baudrate 57600bps Max Full duplex Synchronous Slave Baudrate...

Page 10: ...em User s Manual Ver1 5 Feb 2003 OMH 030 10 10 4 1 3 Connecting the 7188 Embedded Controller to the 7000 module Using Mode 3 Both SST 2450 modules are setting as follows Half Duplex Synchronous Slave...

Page 11: ...450 Wireless Modem User s Manual Ver1 5 Feb 2003 OMH 030 10 11 4 1 4 Connecting a PC to a PLC Using Mode 3 Both SST 2450 modules settings are as follows Half Duplex Synchronous Slave Baudrate 57600bps...

Page 12: ...50 Wireless Modem User s Manual Ver1 5 Feb 2003 OMH 030 10 12 4 1 5 Using the 7188 as a Bridge Using Mode 3 Both SST 2450 modules settings are as follows Half duplex Synchronous Slave Baudrate 57600bp...

Page 13: ...450 Wireless Modem User s Manual Ver1 5 Feb 2003 OMH 030 10 13 4 2 Network communication 4 2 1 Application 1 All SST 2450 modules settings are as follows Half Duplex Synchronous Slave Baudrate 57600bp...

Page 14: ...ST 2450 Wireless Modem User s Manual Ver1 5 Feb 2003 OMH 030 10 14 4 2 2 Application 2 All SST 2450 modules settings are as follows Half duplex Synchronous Slave Baudrate 57600bps Max Data Format E 8...

Page 15: ...When you have finished making the settings you can simply click a button to test the SST 2450 using the same software 5 1 Installing the software Double clicks the Setup exe file which is found in the...

Page 16: ...y However you may choose a different directory by clicking the Change Directory button and selecting the directory where you want to install the software 2 Click the button to install the software 3 C...

Page 17: ...eps When you set the SST 2450 you should never use the following settings SST 2450 A SST 2450 B Half duplex Half duplex Master Slave These settings will cause the SST 2450 set as the Master to be alwa...

Page 18: ...n to continue 2 The following screen will appear From the options shown in the Interface Mode status panel choose a suitable operational mode for your system After making your selections click the Set...

Page 19: ...of the SST 2450 setting tools 2 Click the Testing SST 2450 button on each and the following screens will appear 3 Attempt to send data to each port in the following manner n In the COM1 window type H...

Page 20: ...2450 using the software but are unable to access the setting tool the following screen will appear Follow the steps shown on the error screen Testing error If you are attempting to test your SST 2450...

Page 21: ...er s Manual Ver1 5 Feb 2003 OMH 030 10 21 7 Dimensions 111 10 5 Back View Top View From View Side View O4 5X4 56 00 25 00 40 50 7 30 88 50 35 30 33 00 72 00 25 00 58 50 72 00 56 00 29 50 33 00 2 SCREW...

Page 22: ...SST 2450 Wireless Modem User s Manual Ver1 5 Feb 2003 OMH 030 10 22 8 Din rail Mounting...

Page 23: ...lows the device to be used outdoors The antenna is even water resistant Simply replace the default antenna with an external antenna and you will be able to transmit data across distances of up to 1KM...

Page 24: ...nual Ver1 5 Feb 2003 OMH 030 10 24 9 2 ANT 8 Omni directional Gain 8dBi Polarization Linear Power handling 10W Impedance 50 Ohms Connector SMA Cable RG 58 100cm Gain Pattern Usage Diagram H Plane Fiel...

Page 25: ...anual Ver1 5 Feb 2003 OMH 030 10 25 9 3 ANT 12P Directional Gain 12dBi Polarization Linear Power handling 10W Impedance 50 Ohms Connector SMA Cable RG 58 100cm Gain Pattern Usage Diagram H Plane Field...

Page 26: ...al distributor to get new chip with new firmware Then refer to Figure 10 1 Figure 10 2 and Table 10 1 to adjust the suitable SST 2400 jumper values SST 2400 Jumper definition Figure 10 1 Jumper values...