background image

installation and 
servicing

ESPRIT 2

Your Ideal installation and servicing guide

For details of document amendments, refer to page 3

24, 30, 35

When replacing  any part on this appliance, use only spare parts that you can be assured 
conform to the safety and performance specification that we require. Do not use 
reconditioned or copy parts that have not been clearly authorised by Ideal.

For the very latest copy of literature for specification & maintenance 

practices visit our website www.idealheating.com where you will

be able to download the relevant information in pdf format.

May 2010   UIN  206091 A01

Packaged Boiler Contents have
been Checked by Operator Number.......

206091-1.pmd

26/05/2010, 16:07

1

Summary of Contents for Esprit 2

Page 1: ...onform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for specification maintenance practices visit our website www idealheating com where you will be able to download the relevant information in pdf format May 2010 UIN 206091 A01 Packaged Boiler Contents have b...

Page 2: ...2 ESPRIT 2 Installation and Servicing ...

Page 3: ...T 2 Installation and Servicing DOCUMENT AMENDMENTS Relevant Installation changes implemented in this book from Mod Level A01 May 2010 Ideal Stelrad Group reserve the right to vary specification without notice ...

Page 4: ...erating pressure of water C13 C33 C53 A room sealed appliance designed for connection via ducts to a horizontal or vertical terminal which admits fresh air to the burner and discharges the products of combustion to the outside through orifices which in this case are concentric The fan is up stream of the combustion chamber I2H An appliance designed for use on 2nd Family gas Group H only The value ...

Page 5: ...7593 12 Inhibitor 12 Central heating mode Heat input to be calculated For assistance see Technical Helpline on the back page Page Burner operating pressure n a Central heating flow temp measure and record Central heating return temp measure and record For combination boilers only Scale reducer 12 Hot water mode Heat input to be calculated Max operating burner pressure n a Max operating water press...

Page 6: ... C until DHW is drawn off The full output from the boiler is then directed via the diverter valve to the plate heat exchanger to supply a nominal DHW draw off of 24 9 6 l min at 35 o C temperature rise 30 12 l min at 35 o C temperature rise 35 14 4 l min at 35 o C temperature rise The DHW draw off rate specified above is the nominal that the boiler flow regulator will give Due to system variations...

Page 7: ...le of adequately supporting the weight of the boiler and any ancillary equipment The boiler may be fitted on a combustible wall and insulation between the wall and the boiler is not necessary unless required by the local authority For electrical safety reasons there must be no access available from the back of the boiler The boiler must not be fitted outside Timber Framed Buildings If the boiler i...

Page 8: ...e from boiler suppliers Ask for TFC flue guard model no K6 round plastic coated In case of difficulty contact Grasslin UK Ltd Tel 44 0 01732 359 888 Tower House Vale Rise Fax 44 0 01732 354 445 Tonbridge Kent TN9 1TB www tfc group co uk Ensure that the guard is fitted centrally 5 The flue assembly shall be so placed or shielded as to prevent ignition or damage to any part of any building 6 The air...

Page 9: ...l not fit into a standard depth wall unit In order for it to do so the plastic fascia should be removed See Frame 44 Bottom clearance Bottom clearance after installation can be reduced to 5mm However 100mm must be available for servicing the space into which the boiler is going to be installed is less than the length of flue required the flue must be fitted from the outside Installation from insid...

Page 10: ... thermostatic radiator valves are used the space heating temperature control over a living dining area or hallway having a heating requirement of at least 10 of the boiler heat output should be achieved using a room thermostat whilst other rooms are individually controlled by thermostatic radiator valves However if the system employs thermostatic radiator valves on all radiators or two port valves...

Page 11: ...ler is fitted with an approved anti vacuum or syphon non return valve b Hot and cold water supplies to the shower are of equal pressure CH Return Ecl 6053 Hose unions Mains water supply Temporary hose disconnect after filling Additional stop valve Double check valve assembly note direction of flow The boiler does not normally need a bypass but at least some radiators on the heating circuit of load...

Page 12: ...p recommend the use of Fernox Qantomat Sentinel Combiguard and Calmag CalPhos I scale reducing devices which must be used in accordance with the manufacturers instructions 19 Gas control valve 20 Fan bracket 21 Orifice plate 23 Control thermistor flow return 24 Overheat thermostat 25 Ignition electrode 26 Flame detection electrode 32 Kit Trap and seal 35 User control 36 Primary controls PCB 39 Mai...

Page 13: ...2 Installation and Servicing 62 44 5 4 10 25 17 103 8 11 26 12 13 3 23 32 19 36 39 35 24 71 98 69 74 57 60 18 60 68 67 66 6 51 64 57 75 59 61 40 94 53 14 15 21 16 20 2 1 ispfg9785 8 BOILER ASSEMBLY Exploded View INSTALLATION ...

Page 14: ...the contents Pack A Contents A Boiler B Hardware Pack Box C Wall Mounting Plate D These Installation Users Instructions E Wall Mounting Template located on internal protective packaging F 1 Year Guarantee Pack B Contents A Telescopic flue terminal B Flue turret C Rubber Terminal Wall Seal D Screw E Sealing tape Hardware Pack Contents A Support Bracket 1 off B Accessory Pack C CH Flow Valve Gauge P...

Page 15: ...nd read thoroughly before unpacking the product 5 When ready for installation lift off the cardboard carton 10 PACKAGING REMOVAL 11 BOTTOM AND FRONT PANEL REMOVAL 1 Remove the screw from the underside of the boiler s bottom panel 2 Pull the right hand side of the panel down slide it to the right and withdraw 3 Remove the screws from bottom of the front panel 4 Lift panel up and off top pegs Boiler...

Page 16: ... boiler spacing Dimension S Stand off frame depth 33mm 12 DETERMINING THE FLUE LENGTH AND FLUE PACKS REQUIRED Note MAXIMUM FLUE LENGTHS 24 30 6M HORIZONTAL FLUE 35 3M HORIZONTAL FLUE 24 30 35 7 5M ROOF FLUE 24 30 35 5M PRIMARY AND 17M SECONDARY IS A TYPICAL MAX FLUE LENGTH For alternative details refer to Powered Vertical Instructions 90O ELBOW KIT 60 100 EQUIVALENT FLUE LENGTH RESISTANCE 1M 45O E...

Page 17: ...s and marking the wall to suit this condition 5 Only use water as a lubricant during assembly Do not use mineral based oils 12A DETERMINING THE FLUE LENGTH AND FLUE PACKS REQUIRED CONT D Total Flue length dimension Flue measuring from CL of turret to outside wall Rear flue Side flue Extra packs Boiler dim X 160 dim L 195 required Size Up to 595 mm Up to 595 mm none 24 30 35 Up to 1545 mm Up to 154...

Page 18: ...ct hole see diagram below Note Mark the centre of the hole as well as the circumference 4 Remove the template from the wall 14 WALL MOUNTING TEMPLATE 206091 10144 V See Diagram Below Extended centre line 155 206091 10136 15 PREPARING THE WALL IMPORTANT Ensure that during the cutting operation masonry falling outside of the building does not cause damage or personal injury 1 Cut the flue hole prefe...

Page 19: ... 210mm use non telescopic B Pack 1 Measure and note wall thickness X Refer to Frame 12 2 Add 75mm to dimension X and set telescopic flue length as indicated in drawing 3 Using a 3 5mm drill bit drill one hole in outer air duct taking care not to pierce plastic inner flue 4 Fix to length using self tappers provided 5 Seal outer air duct using the tape provided nm8944 X 75 Drill hole Adhere sealing ...

Page 20: ...ct clamp 1 0m 39 long No 10 x2 wood screw 4 off nm8732 nm8762 Boiler Standard flue Terminal grille Flue length Extension flue Use a maximum of 6m extended flue ONLY 24 30 Use a maximum of 3m extended flue ONLY 35 Because of the flexibility of the telescopic flue terminal it is not always necessary to cut an extension pack 1 Measure the total flue length from the centre of the boiler outlet to the ...

Page 21: ...USINGTHESTAND OFF FRAMEOPTIONKIT To allow pipework to be taken upwards Put the screws into the wall plugs and leave 10mm proud Hang the stand off frame onto the screws and tighten up Fasten the wall mounting plate to the stand off frame with the 6mm screws provided Locate the support bracket on the mounting plate Note If the clearances above and below the boiler are less than the length of the pip...

Page 22: ...prevent possible freezing All pipework and fittings in the condensate drain system must be made of plastic No other materials may be used The drain outlet on the boiler is standard 21 5mm overflow pipe This size must not be reduced in any part of its length If external condensate pipe run is greater than 3m then pipe must be 32mm nominal diameter Consideration should be given to insulating externa...

Page 23: ...wall Ground Level Open end of pipe direct into gulley below grating but above water level DRAIN cla7775 4 TERMINATION TO SOAKAWAY 5 TERMINATION TO DRAIN GULLEY Termination into a down pipe can take place providing it can be confirmed that the down pipe is part of a combined waste and rain water system BOILER External wall Ground Level Termination to Soak away cla7774 minimum 500mm cla9253 BOILER A...

Page 24: ...ared hole in the wall Push through and pull back to seal against outside wall face 3 Locate the flue turret on the top of the boiler ensuring that the turret gasket is in place Also ensure the turret is located concentric with the flue aperture on the boiler top panel Check that the flue seal A located in the top of the flue manifold is secure and giving an effective seal 4 Secure the flue turret ...

Page 25: ...e This is achieved by using either Flat roof weather collar or Universal weather collar ACCESSORIES Flue Duct Extension Kits are available for flue lengths extending beyond 1m These packs contain 1m extension ducts and may be cut to the desired length If the offset vertical option is used an elbow Kit is required For a full accessories list refer to page 7 Optional Extras and Frame 31 Flue Arrange...

Page 26: ...ccur at the termination so where possible terminal positions where this could cause a nuisance should be avoided Minimum dimensions are shown below Terminal Position Minimum Dimension Directly below an opening air brick windows etc 300 mm Below plastic painted gutters 300 mm Painted surface 300 mm Below eaves or balcony 500 mm Below velux window 2000 mm Above or side of velux window 600 mm rf8392 ...

Page 27: ...27 INSTALLATION ESPRIT 2 Installation and Servicing FLUE OUTLET rf8737 rf8738 30 FLUE ARRANGEMENT Note The equivalent flue length resistance of the elbow kits are 90o elbow kit 1m 45o elbow kit 0 6m ...

Page 28: ...weather collar Flat roof tile weather collar 1 nm8741 2 Extension Duct Vertical connector Turret clamp 3 nm8743 X 4 2 Fit the vertical connector supplied separately in accordance with the instructions provided with the vertical connector kit ENSURETHEGASKETSINTHEBOILERFLUEOUTLETARE CORRECTLYFITTED 3 Push fit extension duct if required supplied separately into vertical connector 4 If the last exten...

Page 29: ...he hardware pack to the threaded boss connections provided at the lower rear of the boiler Ensure all boss blanking plugs are removed before connecting hardware Each valve must be fitted to the correct boss as shown in the picture Guidance to correct connection location is also provided on the wall mounting template Ensure each union is fitted with fibre seals provided 2 If connecting the boiler t...

Page 30: ... union Ensure that the gas supply pipe does not foul the boiler casing For additional gas supply information refer to Gas Supply on page 8 34 GAS CONNECTION The safety valve connection located at the bottom right hand side of the boiler comprises a 15mm diameter stub pipe The discharge pipe should be positioned so that the discharge of water or steam cannot create a hazard to the occupants of the ...

Page 31: ...ctions should be protected Central Heating 1 Remove the front panel Refer to Frame 49 2 Ensure that the CH isolating valves are open 3 Fill and vent the system Check for water tightness 4 Pressurise the system to 1 bar Domestic Hot Water 1 Fully open all DHW taps and ensure that water flows freely from them 2 Close all taps Note The domestic hot water flow rate is automatically regulated to a maxi...

Page 32: ...71 Wiring Regulations and any local regulations 38 INTERNAL WIRING A pictorial wiring diagram is shown in Frame 40 This photo shows an external programmer lead on the left and the mains cable on the right 1 Route the mains cable from bottom left hand rear of boiler casing to plug socket connection 2 Wire the permanent live supply into the 5 way remote plug terminals L3 N IMPORTANT A permanent live...

Page 33: ...rentials Frost Protection If parts of the pipework run outside the house or if the boiler will be left off for more than a day or so then a frost thermostat should be wired into the system The frost thermostat should be sited in a cold place but where it can sense heat from the system Earths are not shown for clarity but must never be omitted Diagram B Shows the fitting of a frost thermostat An op...

Page 34: ...g nm9323 Dry fire thermistor Diverter Valve Permanent black link br br pk y g b bk gy r v 1 2 3 y g y g 40 PICTORIAL WIRING DIAGRAM LEGEND b blue bk black br brown gy grey or orange pk pink r red v violet w white y yellow y g yellow green INSTALLATION ...

Page 35: ...carry out the preliminary electrical system checks i e earth continuity polarity resistance to earth and short circuit using a suitable test meter B Gas Installation 1 The whole of the gas installation including the meter should be inspected and tested for tightness and purged in accordance with the recommendations of BS 6891 In IE refer to IS 813 2002 2 Purge air from the gas installation by the ...

Page 36: ...itch the boiler on off switch A to ON The boiler control should now go through its ignition sequence until the burner is established 14 If the boiler does not light after 3 attempts the fault code LF will be displayed Press the select button C and the boiler will repeat its ignition sequence When the burner is established the flame Burner On indicator will be illuminated the LED display will show ...

Page 37: ...e plastic fascia a Prise off the retaining star washers using a pair of pliers and place to one side b Fill the remaining fixing holes with the white push in caps provided 21 Switch the boiler on again DOMESTIC HOT WATER DHW MODE 1 With no call for CH or DHW the boiler should fire for a short period to preheat the DHW plate heat exchanger The LCD display symbol will be returning to none when the b...

Page 38: ... Setting CH Flow DHW Outlet Temp Temp o C o F o C o F Max 82 180 65 150 Min 30 86 42 110 WATER CIRCULATION SYSTEM 1 With the system COLD check that the initial pressure is correct to the system design requirements For pre pressurised systems this should be 1 0 bar 2 With the system HOT examine all water connections for soundness The system pressure will increase with temperature rise but should no...

Page 39: ...lain his her responsibilities under the relevant national regulations 2 Explain and demonstrate the lighting and shutting down procedures 3 The operation of the boiler and the use and adjustment of all system controls should be fully explained to the householder to ensure the greatest possible fuel economy consistent with the household requirements of both heating and hot water consumption Advise ...

Page 40: ...f the boiler refer to Frame 49 or into the flue terminal if access is possible optional test For correct boiler operation the CO CO2 content of the flue gas should not be greater than 0 004 ratio 14 Complete the service section in the Benchmark Commissioning Checklist To ensure the continued safe and efficient operation of the appliance it is recommended that it is checked at regular intervals and...

Page 41: ...bottom and lift to disengage it from the top lugs 1 To remove the sealing panel remove the 4 screws 2 Remove the panel 3 To remove the bottom panel first remove the screw 4 Pull the right hand side of the panel down Slide it to the right and withdraw tim e P R O G R A M M E R pro g pro g sele ct sele ct ispfu9793 FLUE GAS SAMPLING POINT tim e P R O G R A M M E R pro g pro g sele ct sele ct ispfu97...

Page 42: ...POSITION 1 Remove the 2 screws and withdraw the user control 2 Unplug the low voltage electrical lead from the back of the user control 3 Release the clamp 4 Swing the control box down 5 Pull the control box slightly forward nm8433 time P R O G R A M M E R prog prog select select SERVICING ...

Page 43: ...may cause damage to the ceramic 3 Brush off any deposits that may be on the ceramic with a SOFT brush 4 Inspect the sealing gasket around the burner and combustion chamber insulation for any signs of damage Replace as necessary Note Take care not to disturb the ionisation probes at the front and rear of the combustion chamber 1 Disconnect the electrical leads from the fan 2 Undo the gas pipe union...

Page 44: ... that they are clean and in good condition replace if necessary 6 Check the condition of the combustion chamber insulation Any cracked or damaged pieces must be replaced Note Take care not to disturb the ionisation probes at the front and rear of the combustion chamber 7 Check that the ignition and detection gaps are correct Refer to Frames 63 64 7 Refit the boiler sealing panel IMPORTANT Ensure t...

Page 45: ...do the gas pipe union connection to the injector housing 5 Remove the screw retaining the fan mounting bracket 6 Remove the fan and venturi assembly Refer to Frame 52 7 Unscrew the 3 screws and remove the venturi assembly noting the orientation of the venturi in relation to the fan body 8 Transfer the venturi assembly to the new fan replacing the gasket if evidence of damage or deterioration is vi...

Page 46: ...ng the fan mounting bracket 6 Remove the fan and venturi assembly 7 Remove the 2 injector housing screws 8 Withdraw the injector housing 9 Fit the new injector housing complete with injector 10 Reassemble in reverse order ensuring that the new gas seal supplied is located correctly in the injector housing 11 Check operation of the boiler Refer to Frames 45 46 Mounting bracket 7 Ecl 2400 5 Injector...

Page 47: ...the new ignition electrode using the new gasket supplied Check dimensions as shown 8 Reassemble in reverse order and check that no damage to the combustion chamber insulation has occurred during the electrode replacement 9 Check the operation of the boiler Refer to Frames 45 46 6 Fit the new flame detection electrode using the new gasket supplied Check dimensions as shown 7 Reassemble in reverse o...

Page 48: ...tom panel and withdraw the valve upwards 8 Fit the new gas control valve and reconnect gas and electrical connections 9 Re connect the white tube to the valve 10 Check operation of the boiler Refer to Frames 45 46 67 DIVERTER VALVE ACTUATOR REPLACEMENT 1 Refer to Frame 57 2 Swing the control box down into the servicing position Refer to Frame 51 3 Remove the electrical connections 4 Using a suitab...

Page 49: ...bag should be retained and the discarded insulation should now be placed into it 10 Sweep any dampened particles and place in the plastic bag 11 Fit new insulation piece a Locate and align the insulation with the electrode holes and position the insulation into the combustion chamber b Push the flexible material into the corners of the combustion chamber ensuring it is flat and flush against the c...

Page 50: ...own and forward to remove 6 Transfer the drain pipe to the new trap and reassemble in reverse order 7 When reassembling ensure the trap is full of water 8 Check operation of the boiler Refer to Frames 45 46 1 Refer to Frame 57 2 Swing the control box into the servicing position Refer to Frame 51 3 Drain the DHW circuit Refer to Frame 77 4 Unscrew the knurled retaining nut 5 Disconnect the in line ...

Page 51: ...trol box down into the servicing position Refer to Frame 51 4 Unplug the user control electrical lead and low voltage lead from the control box and remove the control Refer to diagram A 5 Return the control box to the working position and secure with the clamp Unscrew the mounting bracket screws to remove the bracket Refer to diagram B 6 Release the clamp and carefully remove the control box from ...

Page 52: ...se order 9 Refill boiler Refer to Frame 36 Check operation of boiler Refer to Frames 45 46 2 itime programmer unit n m 8 4 3 8 tim e PROGRAMMER prog prog select select Note Only the display unit is replaced 1 Refer to Frame 57 2 Loosen the screw on the underside of the user control 3 Pull the display unit forward to remove 4 Push the new display unit into position 5 Reassemble in reverse order 6 C...

Page 53: ...36 Check for leaks around the new air vent joint 15 Check the operation of the boiler Refer to Frames 45 46 PUMP AIR VENT 1 Refer to Frame 57 2 Swing the control box down into the servicing position refer to frame 51 3 Drain the boiler Refer to frame 77 4 Remove the circulating pump head refer to frame 80 5 Locate the automatic air vent head located at the rear of the of pump chamber plastic housi...

Page 54: ...valves re pressurise as appropriate with filling loop before proceeding to check operation of the boiler 6 Check operation of the boiler Refer to Frames 45 46 1 Refer to Frame 57 2 Swing the control box down into the servicing position Refer to Frame 51 3 Drain the boiler Refer to Frame 77 4 Remove the divertor valve actuator head Refer to Frame 67 5 Unscrew the top connection to access the intern...

Page 55: ... plate heat exchanger using the new o rings supplied 9 Reassemble in reverse order 10 Refill the boiler Refer to Frame 36 11 Check operation of the boiler Refer to Frames 45 46 79 DHW PLATE HEAT EXCHANGER REPLACEMENT 80 PUMP HEAD REPLACEMENT 1 Refer to Frame 57 2 Drain the boiler CH circuit Refer to Frame 77 3 Swing the control box down into the servicing position Refer to Frame 51 4 Disconnect th...

Page 56: ... manifold casting and remove 81 HEAT ENGINE RENEWAL 17 Remove the edge clip securing the dry fire thermistor wiring 18 Remove the clip securing the return pipe 19 Remove the overheat thermostat and the control thermistor Refer to Frame 62 20 Remove the clip to release the flow pipe 21 Remove the condensate S trap Refer to Frame 69 22 Remove the 2 M5 screws securing the interpanel to the back panel...

Page 57: ...ame 57 2 Drain the boiler Refer to Frame 77 3 Unscrew all the gas and water connection unions on the boiler side of the valves 4 Remove the screw from the turret clamp and remove 5 Remove the turret 6 Lift the complete boiler from the wall mounting frame and place on a flat surface face down to expose the expansion vessel 7 Unscrew the union nut on the vessel water connection pipe 8 Unscrew the 2 ...

Page 58: ... GO TO FRAME 85 L E GO TO FRAME 86 L A GO TO FRAME 87 L 8 GO TO FRAME 88 H 1 GO TO FRAME 89 H 2 GO TO FRAME 90 H 3 GO TO FRAME 91 H 4 GO TO FRAME 92 H F GO TO FRAME 93 In order to assist fault finding the boiler has an LED diagnostic display The key to the display codes is as follows H n GO TO FRAME 94 H E GO TO FRAME 86 H 9 GO TO FRAME 92 L 9 GO TO FRAME 92 ...

Page 59: ...sh Is 200V DC supply available at the gas valve see Note NO YES YES Is gas pressure available at the boiler inlet Replace PCB Check gas supply and rectify fault Replace ignition electrode and associated harness as necessary NO Replace gas valve YES NO NO Note Due to the wave form of the rectified voltage the reading will vary depending on the type of meter used to measure the value some may measur...

Page 60: ... YES YES YES YES Check earth connection to the boiler If it is still in excess of 50 V consult a qualified electrician to check the household electrical supply and circuitry LE ONLY Is continuity of OH thermostat correct Correct wiring or replace thermostat HE ONLY Is earth wire connected to detection lead correctly Correct wiring or replace detection lead Have all earths been checked for continui...

Page 61: ...ith water and all isolation and radiator valves open OK NO YES NO Replace overheat thermostat 88 L 8 FAN ERROR Is nominal 330 V DC present across red and blue at the fan connector as reset button is pressed Replace fan YES NO Replace harness 89 H 1 CONTROL THERMISTOR FLOW ERROR YES Is there continuity between the PCB and the thermistor Check resistance using a suitable multimeter connected across ...

Page 62: ...inuity between the PCB and the thermistor Remove the boiler DHW thermistor from the plate heat exchanger and disconnect thermistor wires Are the thermistor values correct Replace the thermistor NO NO YES Replace PCB Check and replace wiring as necessary Check resistance using a suitable multimeter connected across the thermistor s terminal pins At 25 o C expect 9 700 10 300 Ohms At 60 o C expect 2...

Page 63: ...and vented with a system pressure of approximately 1bar H9 L9 HEAT EXCHANGER OVERHEAT Is the system filled and vented and all isolation valves open including TRV s Bypass Check the pump is operating correctly in Heating DHW and check temp diffs across Flow Return YES NO Fill and vent the system and open all isolating valves Are thermistor values correct Check that a permanently open bypass circuit...

Page 64: ... user control programmer 1 174 487 36 H49 852 PCB primary controls kit V9 1 174 486 37 E67 519 Fuse PCB 3 15A L250V 1 170 931 39 HO7 777 Mains switch c w harness 1 173 537 40 HO7 731 Spark generator assy 1 173 538 45 E67 527 Gasket kit servicing 1 170 938 52 E68 376 Seal kit sealing panel 1 171 014 53 E68 380 Turret gasket 1 171 022 61 H66 650 Pressure relief valve 1 175 413 62 H66 652 Expansion v...

Page 65: ...65 SHORT LIST OF PARTS ESPRIT 2 Installation and Servicing 95 SHORT LIST 103 98 ispfu9879 ...

Page 66: ...el with screw 97 CONTROLS ASSEMBLY 33 Controls assy with screws 34 Controls hinge bracket 35 User controls without item 38 36 PCB primary controls 38 User controls housing 39 Mains switch 54 Jumper link not shown 98 BURNER ASSEMBLY 11 Burner assembly with screws and gasket ispfu8441a 36 34 39 38 35 time P R O G R A M M E R prog prog select select ...

Page 67: ...67 ESPRIT 2 Installation and Servicing ...

Page 68: ......

Page 69: ... contact a government approved inspector LABC will record the data and will issue a certificate of compliance If you notify via Gas Safe Register they will then notify the relevant Local Authority Building Control LABC scheme on members behalf Gas Safe Register Engineers log on to the engineers section of the website at www gassaferegister co uk or telephone 0800 408 5577 You must ensure that the ...

Page 70: ...Gas Safe Register ID Number ...

Page 71: ...gister ID Number Gas Safe Register ID Number Gas Safe Register ID Number Gas Safe Register ID Number Gas Safe Register ID Number Gas Safe Register ID Number Gas Safe Register ID Number Gas Safe Register ID Number Gas Safe Register ID Number ...

Page 72: ... to vary specification without notice The Ideal Technical Training Centre offers a series of first class training courses for domestic commercial and industrial heating installers engineers and system specifiers For details of courses please ring 01482 498 432 Manufactured under an ISO 9001 registered quality management system The code of practice for the installation commissioning servicing of ce...