background image

USERS GUIDE

LOGIC Combi ES
ES24, ES30, ES35

When replacing any part on this appliance, use only spare parts that you can be
assured conform to the safety and performance specification that we require.  
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

For installation guide see reverse of book 

Summary of Contents for LOGIC Combi ES24

Page 1: ...art on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For installation guide see reverse of book ...

Page 2: ...neer in accordance with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordance with the current edition of I S 813 Domestic Gas Installations the current Building Regulations and reference should be made to the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly fo...

Page 3: ...ler which is most efficient when operating in condensing mode The boiler will operate in this mode if the CH temperature control C is set to the e position economy mode This control should be set to maximum for very cold periods To shut down the boiler Set the mode knob control to OFF To relight the boiler Repeat the procedure detailed in To light the boiler Frost protection If no system frost pro...

Page 4: ...ther localised hazards 4 Once the blockage is removed and the condensate can flow freely reset the appliance Refer to To Light the boiler 5 If the appliance fails to ignite call your Gas Safe Registered engineer Preventative solutions During cold weather set the boiler stat to maximum Must return to original setting once cold spell is over Place the heating on continuous and turn the room stat dow...

Page 5: ...entral heating Check the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL HEATING Check the fused spur is turned on and ensure switch mode control knob D is in the winter position See boiler Operation Modes and Fault Codes section Does ...

Page 6: ...s a call for central heating but the appliance has reached the desired temperature set on the boiler The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating mode The boiler is operating in hot water mode The boiler is operating in frost mode continued OPERATION MODES ...

Page 7: ...RIPTION Low Water Pressure ACTION Check system pressure is between 1 1 5bar on the pressure gauge If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Flame Loss 1 Check other gas appliances in the house are working to confirm a supply is present in ...

Page 8: ...1482 448858 Registration No London 322 137 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice Ideal Consumer Helpline Tel 01482 498660 www idealheating com ...

Reviews: