background image

NEW BUILD 

YOUR COMPLETE 

SOLUTION.

WWW.IDEALBOILERS.COM

IDEAL

BOILER

STELRAD

RADIATOR

CYLINDER

SOLAR

PANEL

FREE DESIGN

STAGE SAP

(USUALLY £50)

DESIGN

SERVICE

364 DAYS

A YEAR

Summary of Contents for COMBI ESP 24

Page 1: ...NEW BUILD YOUR COMPLETE SOLUTION WWW IDEALBOILERS COM IDEAL BOILER STELRAD RADIATOR CYLINDER SOLAR PANEL FREE DESIGN STAGE SAP USUALLY 50 DESIGN SERVICE 364 DAYS A YEAR ...

Page 2: ... OUR AWARD WINNING BOILERS GO THROUGH 200 QUALITY CHECKS BEFORE THEY LEAVE THE FACTORY AND ARE AVAILABLE WITH A RANGE OF FLEXIBLE WARRANTY OPTIONS YOU CAN REST ASSURED RELIABILITY IS GUARANTEED WHEN YOU PARTNER WITH IDEAL 02 ...

Page 3: ...CONTENTS 04 THE IDEAL PRODUCT RANGE 06 LOGIC COMBI ESP 14 LOGIC CODE COMBI ES 22 LOGIC SYSTEM 30 LOGIC HEAT 38 BOILER CONTROLS 42 LPG CONVERSION KITS 44 FLUE SITING 46 FLUEING OPTIONS 71 CONTACT US 03 ...

Page 4: ...ing design the Logic range of boilers offers state of the art technology in a practical compact unit that fits easily into any standard kitchen cupboard Available in a range of outputs the Logic range comes complete with a flexible parts and labour warranty package 04 ...

Page 5: ...CODE COMBI ES A simple one box solution capable of supporting up to level 4 of the code for sustainable homes with built in flue gas heat recovery LOGIC SYSTEM A simple and reliable solution for a wide variety of sealed domestic systems LOGIC HEAT ONLY Highly efficient and easy to operate thanks to straightforward controls featuring a clear digital display 05 ...

Page 6: ...Y COMBINATION BOILERS Optimised for new build compliance following the SAP 2009 2012 design procedure the Logic Combi ESP achieves improved SAP efficiency scores and is particularly beneficial for new build properties LOGIC COMBI ESP 24 30 35 ...

Page 7: ...esign Two stage flame sensing for greater reliability Latest generation Honeywell gas valve ErP compliant EASY TO INSTALL Compact cupboard fit Fast fix flues Wide range of additional flueing options Low lift weight 32kg Easy access to PRV and AAV Preformed copper tails Pre wired mains lead 2m Universal condensate connection Stand off kit including piping available Compatible with a range of additi...

Page 8: ...is required for servicing Bottom clearance after installation can be reduced to 5mm However 100mm is required for servicing FLUE LENGTHS CLEARANCES AND DIMENSIONS COMBI ESP 24 COMBI ESP 30 COMBI ESP 35 Max horizontal 9m 8m 6m Max vertical 7 5m 7 5m 7 5m Powered vertical 22m 22m 22m 8 DIMENSIONS Height 700mm Width 395mm Depth 278mm DIMENSIONS IN MM ...

Page 9: ...35 Weight packaged kg 36 3 36 5 36 5 Max installation weight kg 31 8 32 0 32 0 CH output kW min max 70 C 4 8 24 2 6 1 24 2 7 1 24 2 CH output kW min max 40 C 5 1 25 6 6 4 25 6 7 5 25 6 DHW output kW max 24 2 30 3 35 3 DHW flow rate l min 35 C rise 9 9 12 4 14 5 SEDBUK rating 2005 91 91 1 91 SEDBUK rating 2009 2012 89 0 89 0 88 9 NOx classification CLASS 5 CLASS 5 CLASS 5 Adjustable to LPG No Yes N...

Page 10: ...nged visit where access is not gained by the engineer 10 NO HOT WATER Check the mains switch fused spur is turned on and ensure switch mode control knob D Control Panels P 38 is in the summer or winter position Is water coming out of the hot water tap when turned on See boiler Fault Codes section If 0 is displayed then contact Ideal Customer Services Helpline if your appliance is under warranty or...

Page 11: ...O CENTRAL HEATING Check the mains switch fused spur is turned on and ensure switch mode control knob D Control Panels P 38 is in the winter position Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up Does the boiler operate and provide central heating Check the time settings on the programmer are as you require and adjust if necessary ...

Page 12: ...if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII False flame lockout Reset the appliance if the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII DISPLAY COD...

Page 13: ...s and restart the boiler Check that the pumps are rotating freely and the flow and return have a differential across the boiler in excess of 30 C Flame loss 1 Check other gas appliances in the house are working to confirm a supply is present in the property 2 If other appliances do not work or there are no other appliances check the gas supply is on at the meter and or pre payment meter has credit...

Page 14: ... COMBINATION BOILERS Designed to take the headache out of meeting Building Regulations the Logic Code Combi ES from Ideal is a simple one box solution capable of supporting up to level 4 of the Code for Sustainable Homes LOGIC CODE COMBI ES 26 33 38 ...

Page 15: ...ficiency reduced running costs Less waste DHW water as DHW inlet is preheated Reduced pluming on DHW ErP compliant EASY TO INSTALL One single appliance to install quick and easy Built in pipework no extra space at the side of the product needed Standard combination connections No additional maintenance requirement Compact and light solution for new build or retrofit installations Available with 38...

Page 16: ...ired for servicing Bottom clearance after installation can be reduced to 5mm However 100mm is required for servicing FLUE LENGTHS CLEARANCES AND DIMENSIONS CODE COMBI ES 26 CODE COMBI ES 33 CODE COMBI ES 38 Max horizontal 9m 8m 6m Max vertical 7 5m 7 5m 7 5m Powered vertical 22m 22m 22m 16 DIMENSIONS Height 830mm Width 395mm Depth 278mm DIMENSIONS IN MM ...

Page 17: ...ged kg 39 5 39 7 39 7 Max installation weight kg 34 7 34 9 34 9 CH output kW min max 70 C 4 8 24 2 6 1 24 2 7 1 24 2 CH output kW min max 40 C 5 1 25 6 6 4 25 6 7 5 25 6 DHW output kW max 26 1 32 7 38 2 DHW flow rate l min 35 C rise 10 7 13 4 15 7 SEDBUK rating 2005 91 91 1 91 SEDBUK rating 2009 2012 89 0 89 0 88 9 NOx classification CLASS 5 CLASS 5 CLASS 5 Adjustable to LPG No No Yes Condensing b...

Page 18: ... access is not gained by the engineer TROUBLESHOOTING 18 NO HOT WATER Check the mains switch fused spur is turned on and ensure switch mode control knob D Control Panels P 38 is in the summer or winter position Is water coming out of the hot water tap when turned on See boiler Fault Codes section If 0 is displayed then contact Ideal Customer Services Helpline if your appliance is under warranty or...

Page 19: ...O CENTRAL HEATING Check the mains switch fused spur is turned on and ensure switch mode control knob D Control Panels P 38 is in the winter position Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up Does the boiler operate and provide central heating Check the time settings on the programmer are as you require and adjust if necessary ...

Page 20: ...ler RGII No water flow thermistor Reset the appliance if the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII DISPLAY CODE ON THE BOILER DESCRIPTION The boiler is in standby mode awaiting either a central heating call or hot water demand The boiler has ...

Page 21: ... warranty period In IE contact a Registered Gas Installer RGII Flow temperature overheat or no water flow Is the boiler and CH heating system filled and all isolation vales and radiators open If not then fill and vent the system and open all isolation valves and restart the boiler Check that the pumps are rotating freely and the flow and return have a differential across the boiler in excess of 30...

Page 22: ...YSTEM 15 18 24 30 22 HIGH EFFICIENCY SYSTEM BOILERS The Logic System range of appliances from Ideal provide a simple and reliable solution for a wide variety of sealed domestic systems LOGIC SYSTEM 15 18 24 30 ...

Page 23: ...for better reliability EASY TO INSTALL Compact cupboard fit Wide range of flueing options Concealed pipe connections Low lift weight 27 7kg Preformed copper tails LPG Conversion kit available for 30 kW boilers System IE 24 kW Stand off kit and pre pipe options Pre wired mains lead Easy Access to PRV and AAV Universal condensate connection 30 kW only 6 1 kW Available with IE 24 30 kW models Weight ...

Page 24: ...oard door open is required for servicing Bottom clearance after installation can be reduced to 5mm However 100mm is required for servicing FLUE LENGTHS CLEARANCES AND DIMENSIONS SYSTEM 15 SYSTEM 18 Max horizontal 9m 9m Max vertical 7 5m 7 5m Powered vertical 22m 22m 24 DIMENSIONS Height 700mm Width 395mm Depth 278mm DIMENSIONS IN MM ...

Page 25: ... 5 1 25 6 6 4 31 0 DHW output kW max n a n a n a n a DHW flow rate l min 35 C rise n a n a n a n a SEDBUK rating 2005 91 1 91 91 91 1 SEDBUK rating 2009 2012 89 3 89 2 89 5 89 6 NOx classification CLASS 5 CLASS 5 CLASS 5 CLASS 5 Adjustable to LPG No No Yes Yes Condensing boiler Yes Yes Yes Yes Seasonal space heating efficiency class A A A A Rated heat output kW 15 18 24 30 Seasonal space heating e...

Page 26: ... arranged visit where access is not gained by the engineer NO HOT WATER Check the mains switch fused spur is turned on and ensure mode control knob B Control Panels P 39 is in the ON position Check the programmer is in an ON position and the cylinder thermostat is turned up Does the boiler operate and provide hot water Check the time settings on the programmer are as you require and adjust if nece...

Page 27: ... mode NO CENTRAL HEATING Check the mains switch fused spur is turned on and ensure mode control knob B Control Panels P 39 is in the ON position Check the programmer is in an ON position and the room thermostat is turned up Does the boiler operate and provide central heating Check the time settings on the programmer are as you require and adjust if necessary See boiler Operation Modes and Fault Co...

Page 28: ...and on at the fused spur 2 If the boiler fails to operate please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII False flame lockout Reset the appliance if the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside o...

Page 29: ...her appliances check the gas supply is on at the meter and or pre payment meter has credit If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Fan fault Reset the appliance if the boiler fails to operate then please contact Ideal if under warranty o...

Page 30: ...LOGIC HEAT 12 15 18 24 30 30 HIGH EFFICIENCY HEAT BOILERS Designed to be installed with the minimum of fuss Logic appliances offer a speedy installation LOGIC HEAT 12 15 18 24 30 ...

Page 31: ...ompact cupboard fit Direct 80mm diameter rear flue option Wide range of flueing options Low lift weight 22 8kg Top system connections 75mm deep translucent condensate siphon Stand off kit Terminal wall plate kit Security bracket kit Low minimum head requirement LPG conversion kit available for 24 kW 30 kW boilers Available with 24 30 kW models 30 kW only 6 1 kW Available to download from www ideal...

Page 32: ...for servicing Bottom clearance after installation can be reduced to 5mm However 100mm is required for servicing Rear flue option top clearance 100mm FLUE LENGTHS CLEARANCES AND DIMENSIONS 32 HEAT 12 HEAT 15 HEAT 18 Max horizontal 9m 9m 9m Max vertical 7 5m 7 5m 7 5m Powered vertical 22m 22m 22m DIMENSIONS Height 700mm Width 395mm Depth 278mm DIMENSIONS IN MM ...

Page 33: ...6 6 4 31 0 DHW output kW max n a n a n a n a n a DHW flow rate l min 35 C rise n a n a n a n a n a SEDBUK rating 2005 91 2 91 1 91 91 91 1 SEDBUK rating 2009 2012 89 4 89 3 89 2 89 5 89 6 NOx classification CLASS 5 CLASS 5 CLASS 5 CLASS 5 CLASS 5 Adjustable to LPG No No No Yes Yes Condensing boiler Yes Yes Yes Yes Yes Seasonal space heating efficiency class A A A A A Rated heat output kW 12 15 18 ...

Page 34: ...cess is not gained by the engineer NO CENTRAL HEATING OR HOT WATER Check the mains switch fused spur is turned on and ensure mode control knob B Control Panels P 39 is in the ON position Check the Timer is in an ON position and the room thermostat is turned up Does the boiler operate and provide central heating Check the time settings on the programmer are as you require and adjust if necessary NO...

Page 35: ...tact a Registered Gas Installer RGII Unconfigured PCB Reset the appliance if the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Flame loss See Action Fault Code L 2 DISPLAY CODE ON THE BOILER DESCRIPTION The boiler is in standby mode awaiting either a...

Page 36: ...utside of the warranty period In IE contact a Registered Gas Installer RGII Outside sensor failure Reset the appliance if the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Low mains voltage Contact a qualified electrician or your electricity provider...

Page 37: ...at the meter and or pre payment meter has credit If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Boiler resets in 15 minutes 1 Turn power off and on at the fused spur 2 If the boiler fails to operate please contact Ideal if under warranty or alt...

Page 38: ...d In this event conduct the re pressurising procedure as show on page 4 of the User Manual WINTER OPERATION COMBI 1 Ensure gas and electric supplies are available and on i e card meters are topped up 2 Ensure boiler thermostat C is on and set two thirds of the way round 3 Set room thermostat to desired temperature normally between 20 23 C 4 Control individual room via Thermostatic Radiator Valves ...

Page 39: ...ay C will show the following codes 0 Standby no demand for heat C Central Heating being supplied F boiler frost protection boiler fires if temperature is below 5 C If the pressure is seen to fall below the original installation pressure of 1 2 bar over a period of time then a water leak may be indicated In this event conduct the re pressurising procedure as show on page 4 of the User Manual In nor...

Page 40: ...24 hour tappet operation with off timed continuous periods ELECTRONIC TIMER Part No 204545 ErP Class 0 no additional efficiency Easy to use heating control through a plug in digital timer Plain text operating and diagnostics information 7 day and up to 3 time periods day Automatic summer winter time update RF MECHANICAL PROGRAMMABLE THERMOSTAT Part No 204824 ErP Class 1 1 additional efficiency If ...

Page 41: ...r wiring and features a 24hr The room thermostat can be freestanding or wallmounted and has a COMBI HEAT ONLY SYSTEM CONTROLS WEATHER COMPENSATION OUTDOOR SENSOR Part No 211326 combi models only ErP Class 2 2 additional efficiency Part No 211332 heat only and system models ErP Class 2 2 additional efficiency The Logic and Logic Code Combi ES ranges provide weather compensation when fitted with an ...

Page 42: ...natural gas kits these quick to install accessories provide a simple and pragmatic solution without the need for products to be adjusted Each kit contains specific components for each required boiler type Available for all product types combi heat system Suitable for most property sizes Fast simple conversion with preset gas valve for no product adjustment FEATURES Logic Code Combi ES 38 Logic Com...

Page 43: ...TEM 30 Min output kW 4 8 6 1 7 1 4 8 6 1 4 8 6 1 Max output kW 24 2 24 2 24 2 24 2 30 3 24 2 30 3 Max DHW output kW 24 2 30 3 38 2 N A N A N A N A NG LPG CONVERSION KIT PRODUCT CODE LOGIC CODE COMBI ES38 211382 LOGIC COMBI 24 ErP 213374 LOGIC COMBI 24 212115 LOGIC COMBI 30 ErP 213342 LOGIC COMBI 30 211370 LOGIC COMBI ES ESP30 ErP 213343 LOGIC HEAT 24 212114 LOGIC HEAT 30 211372 LOGIC SYSTEM IE 24 ...

Page 44: ...f BS5440 1 2008 25mm 1 200mm 8 5 From vertical drain pipes or soil pipes BS5440 1 2008 25mm 1 150mm 6 6 From an internal or external corner or to a boundary alongside the terminal BS5440 1 2008 25mm 1 300mm 12 7 Above ground roof or balcony level 300mm 12 8 From a surface or a boundary facing a terminal 600mm 24 9 From a terminal facing a terminal 1200mm 48 10 From an opening in a car port eg door...

Page 45: ... 9 14 7 1 4 10 6 11 11 45 A A B B If chimney penetrates dotted area such that A is less than 300mm B shall not be less than 300mm A 600mm B 2000mm The flue terminal shall not penetrate the shaded area of the roof R F 9 8 0 7 A A B A ...

Page 46: ...169 484 Horizontal flue terminal 0 6m long 6 x Flue extension 1m pack D 208171 6 x 203129 6256 35 max length 6m Telescopic B pack flue 0 6m long 6 x Flue extension 1m pack D 208169 6 x 203129 6184 35 max length 6m Horizontal flue terminal 0 6m long 8 x Flue extension 1m pack D 208171 8 x 203129 8186 30 max length 8m Telescopic B pack flue 0 6m long 8 x Flue extension 1m pack D 208169 8 x 203129 80...

Page 47: ...1 5 x 203129 203130 5306 35 max length 5m 1x 90 elbow Telescopic B pack flue 0 6m long 5 x Flue extension 1m pack D Flue 90 elbow kit 60 100 208169 5 x 203129 203130 5234 35 max length 5m 1x 90 elbow Horizontal flue terminal 0 6m long 7 x Flue extension 1m pack D Flue 90 elbow kit 60 100 208171 7 x 203129 203130 7236 30 max length 7m 1x 90 elbow Telescopic B pack flue 0 6m long 7 x Flue extension ...

Page 48: ... 100 208171 4 x 203129 2 x 203130 4356 35 max length 4m 2x 90 elbow Telescopic B pack flue 0 6m long 4 x Flue extension 1m pack D 2 x Flue 90 elbow kit 60 100 208169 4 x 203129 2 x 203130 4284 35 max length 4m 2x 90 elbow Horizontal flue terminal 0 6m long 6 x Flue extension 1m pack D 2 x Flue 90 elbow kit 60 100 208171 6 x 203129 2 x 203130 6286 30 max length 6m 2x 90 elbow Telescopic B pack flue...

Page 49: ...203131 5306 35 max length 4 8m 2 x 45 elbow Telescopic B pack flue 0 6m long 5 x Flue extension 1m pack D 2 x Flue elbow 45 kit 60 100 208169 5 x 203129 203131 5234 35 max length 4 8m 2 x 45 elbow Horizontal flue terminal 0 6m long 7 x Flue extension 1m pack D 2 x Flue elbow 45 kit 60 100 208171 7 x 203129 203131 7236 30 max length 6 8m 2 x 45 elbow Telescopic B pack flue 0 6m long 7 x Flue extens...

Page 50: ...259 Weather collar flat roof 100 dia FLUE IDEAL PART NO MAXIMUM STRAIGHT FLUE LENGTH MM Roof flue kit with vertical connector Weather collar 211039 152258 152259 1325 Roof flue kit 7 x max Flue extension 1m pack D Weather collar 211039 7 x 203129 152258 152259 7500 FLUE IDEAL PART NO MAXIMUM STRAIGHT FLUE LENGTH MM Roof flue kit with vertical connector 6 x max Flue extension 1m pack D 2 x Flue elb...

Page 51: ...e wall is available Permits the concentric flue to run vertically from the top of the boiler and obtain air supply within the roof space the secondary flue continuing to the external flue terminal Offset applications are permissible though the maximum length is reduced 152258 Weather collar universal 100 dia suits any roof pitch 152259 Weather collar flat roof 100 dia Where extension D packs are c...

Page 52: ...0 packaged pair Ideal part no 203129 Flue extension 1m Pack D Flue powered vertical terminal 100 dia Ideal part no 203134 Ideal part no 208171 Horizontal flue terminal 0 6m long Ideal part no 208169 Telescopic B pack flue 0 6m long Ideal part no 208174 Telescopic horizontal flue terminal 1m long Flue vertical connector Ideal part no 208175 Flue deflector 60 dia Ideal part no 208176 FLUEING INSTALL...

Page 53: ...211039 Roof flue kit inc vertical connector Ideal part no 159991 Condensate pump kit Ideal part no 211101 Stand off kit 2 Inc piping Ideal part no 211103 Stand off kit 1 Ideal part no Terminal wall plate RS replacement kit Ideal part no 206712 Pressure gauge 3 extension kit 211326 Combi Ideal part no 211332 Heat System 211328 Combi System 206164 Heat Weather compensation kit 1 Combi System only fo...

Page 54: ...T SYSTEM Pre piping kit 211041 Pre piping kit 211331 Security bracket kit 205217 INSTALLATION ACCESSORIES IDEAL PART NO COMBI HEAT SYSTEM OpenTherm harness kit 211327 PRV wall outlet pipe kit 205126 DHW expansion vessel kit 205419 FLUEING INSTALLATION ACCESSORIES LOGIC COMBI ESP HEAT SYSTEM 54 ...

Page 55: ...ed horizontal flue outlet kit Ideal part no 208290 55 NOTE A 1 metre vertical pipe is supplied as standard Both horizontal and vertical lengths can be extended using extension pack D Refer to installation instructions for maximum lengths ...

Page 56: ...lue exit to terminate with a 90 elbow complete with grille Push fit one metre extension pipes are used as required and the fixing clips supplied support the system from the wall Both 90 and 45 elbows are available to provide routing options THE KIT COMPRISES Flue elbow 1 off 60mm flue exit elbow 1 off 60mm horizontal flue exit 1 off 60mm x 500mm flue outlet extension pipe 1 off This kit is specifi...

Page 57: ...t least 1 back to the boiler VERTICAL HORIZONTAL LEFT OR RIGHT 45 LEFT OR RIGHT LOGIC ALL MODELS IDEAL PART NO High level flue outlet kit 208178 Logic Heat rear flue outlet 55 80 ONLY high level flue outlet kit 55 80 205989 Flue extension kit 60 dia 1m for high level flue outlet kit 203228 High level 90 elbow 203229 High level 45 elbow 203230 LOGIC ALL MODELS METRES 90 elbow 1 4 45 elbow pair 1 25...

Page 58: ...ss permissible is 115mm No extensions are permitted FLUEING ACCESSORIES IDEAL PART NO Rear outlet flue terminal 55 80 205990 Flue finishing kit 55 80 206151 For 1m extension and elbows use standard parts 203228 9 30 LOGIC HEAT ONLY IDEAL PART NO High level outlet kit 55 80 205989 FLUEING OPTIONS LOGIC HEAT REAR OUTLET FLUE TERMINAL 55 80 80MM 58 ...

Page 59: ...e retained FLUE IDEAL PART NO MAXIMUM STRAIGHT FLUE LENGTH MM Horizontal flue terminal 0 6m long 208171 556 Horizontal flue terminal 0 6m long 6 x Flue extension 1m pack D 208171 6 x 203129 6256 38 max length 6m Horizontal flue terminal 0 6m long 8 x Flue extension 1m pack D 208171 8 x 203129 8186 33 max length 8m Horizontal flue terminal 0 6m long 9 x Flue extension 1m pack D 208171 9 x 203129 90...

Page 60: ...O MAXIMUM STRAIGHT FLUE LENGTH MM Horizontal flue terminal 0 6m long Flue 90 elbow kit 60 100 208171 203130 556 Horizontal flue terminal 0 6m long 5 x Flue extension 1m pack D Flue 90 elbow kit 60 100 208171 5 x 203129 203130 5306 38 max length 5m 1x 90 elbow Horizontal flue terminal 0 6m long 7 x Flue extension 1m pack D Flue 90 elbow kit 60 100 208171 7 x 203129 203130 7236 33 max length 7m 1x 9...

Page 61: ...Horizontal flue terminal 0 6m long 2 x Flue 90 elbow kit 60 100 208171 2 x 203130 556 Horizontal flue terminal 0 6m long 4 x Flue extension 1m pack D 2 x Flue 90 elbow kit 60 100 208171 4 x 203129 2 x 203130 4356 38 max length 4m 2x 90 elbow Horizontal flue terminal 0 6m long 6 x Flue extension 1m pack D 2 x Flue 90 elbow kit 60 100 208171 6 x 203129 2 x 203130 6286 33 max length 6m 2x 90 elbow Ho...

Page 62: ...IGHT FLUE LENGTH MM Horizontal flue terminal 0 6m long 2 x Flue elbow 45 kit 60 100 208171 203131 556 Horizontal flue terminal 0 6m long 5 x Flue extension 1m pack D 2 x Flue elbow 45 kit 60 100 208171 5 x 203129 203131 5306 35 max length 4 8m 2 x 45 elbow Horizontal flue terminal 0 6m long 7 x Flue extension 1m pack D 2 x Flue elbow 45 kit 60 100 208171 7 x 203129 203131 7236 30 max length 6 8m 2...

Page 63: ...lar 203132 208175 7 x 203129 152258 152259 7500 NOTE 152258 Weather collar universal 100 dia suits any roof pitch 152259 Weather collar flat roof 100 dia FLUE IDEAL PART NO MAXIMUM STRAIGHT FLUE LENGTH MM Roof flue kit with vertical connector 6 x max Flue extension 1m pack D 2 x Flue elbow 45 kit 60 100 Weather collar 211039 6 x 203129 203131 152258 152259 6300 NOTE 152258 Weather collar universal...

Page 64: ...no access to an outside wall is available Permits the concentric flue to run vertically from the top of the boiler and obtain air supply within the roof space the secondary flue continuing to the external flue terminal Offset applications are permissible though the maximum length is reduced 152258 Weather collar universal 100 dia suits any roof pitch 152259 Weather collar flat roof 100 dia Where e...

Page 65: ...ckaged Ideal part no 203131 Flue elbow 45 kit 60 100 packaged pair Ideal part no 203129 Flue extension 1m Pack D Flue powered vertical terminal 100 dia Ideal part no 203134 Ideal part no 208171 Horizontal flue terminal 0 6m long Ideal part no 208169 Telescopic B pack flue 0 6m long Ideal part no 208174 Telescopic horizontal flue terminal 1m long Flue vertical connector Ideal part no 208175 Flue de...

Page 66: ...al part no 205024 Ideal part no 211039 Roof flue kit inc vertical connector Ideal part no 205419 DHW expansion vessel kit Ideal part no 206679 Stand off kit Inc piping Ideal part no 159991 Condensate pump kit Ideal part no 206383 Stand off kit Ideal part no 206712 Pressure gauge extension kit 211326 Ideal part no Weather compensation kit Flue extension pipe 80 dia pair twin vertical Ideal part no ...

Page 67: ...SSORIES IDEAL PART NO Pre piping kit 206704 Security fixing kit 206708 INSTALLATION ACCESSORIES IDEAL PART NO OpenTherm harness kit 204915 PRV wall outlet pipe kit 205126 Balcony flue outlet kit Ideal part no 208177 67 ...

Page 68: ...utlet kit Ideal part no 208290 NOTE A 1 metre vertical pipe is supplied as standard Both horizontal and vertical lengths can be extended using extension pack D Refer to installation instructions for maximum lengths FLUEING ACCESSORIES LOGIC CODE COMBI ES 68 ...

Page 69: ...ate with a 90 elbow complete with grille Push fit one metre extension pipes are used as required and the fixing clips supplied support the system from the wall Both 90 and 45 elbows are available to provide routing options THE KIT COMPRISES Flue elbow 1 off 60mm flue exit elbow 1 off 60mm horizontal flue exit 1 off 60mm x 500mm flue outlet extension pipe 1 off This kit is specified for use with th...

Page 70: ...IMPORTANT Flue must always slope at least 1 back to the boiler VERTICAL HORIZONTAL LEFT OR RIGHT 45 LEFT OR RIGHT 70 LOGIC CODE COMBI ES IDEAL PART NO High level flue outlet kit 208178 Flue extension kit 60 dia 1m for high level flue outlet kit 203228 High level 90 elbow 203229 High level 45 elbow 203230 LOGIC CODE COMBI ES METRES 90 elbow 1 4 45 elbow pair 1 25 ...

Page 71: ...specialist teams they are on hand to help you 7 days a week 364 days a year CUSTOMER SERVICE Tel 01482 498660 SALES ORDERS AND ENQUIRIES Tel 0844 498056 TECHNICAL HELP Tel 01482 498663 IDEAL GENUINE PARTS Tel 01482 498665 MAIN RECEPTION Tel 01482 492251 71 ...

Page 72: ...Ideal Boilers PO Box 103 National Avenue Kingston upon Hull East Yorkshire HU5 4JN T 01482 492251 GREAT BOILERS FROM GREAT BRITAIN WWW IDEALBOILERS COM 02 2016 211153 v5 5 ...

Reviews: