background image

Summary of Contents for Europa 224

Page 1: ......

Page 2: ...case must be allowed for servicing After installation the following clearances are allowable during use providing the encasing parts are removeable for servicing The bottom clearance can be reduced to 20mm 3 4 The front clearance can be reduced to 50mm 2 BOILER CONTROLS B C D E F G A A Appliance On lamp B Domestic hot water temperature control C Main switch and radiator temperature control D Boile...

Page 3: ... SHUT DOWN THE BOILER For short periods To turn the boiler off set the function selector C to the O position The appliance On lamp A will flash every 4 seconds For long periods When you do not expect to use the boiler for a long period 1 Switch the electricity supply off 2 Shut off the gas supply cock and the valves for the water circuits fitted under the boiler 3 If necessary empty the water circ...

Page 4: ... above for the ON setting and confirm by pressing the enter button D Proceed in the same way for other settings Setting example shown in Fig 3 A ON time 7 45 day Monday to Friday B OFF time 10 30 day Monday to Friday A B Fig 3 Activating the timed settings Set the mode selector switch B to the AUTO position shown in Fig 4 The current time and day appears in the display The ON OFF display A indicat...

Page 5: ...ssing the button E or F and the operation can be forced on or off by pressing the button G The time delay can be set within the following ranges 1 to 23 hours with steps of 1 hour 1 to 27 days with steps of 1 day The time delay setting is activated by moving the switch B to the AUTO position The ON OFF display A flashes indicating that the current state of operation has been forced To delete the t...

Page 6: ...ition F Check that air pressure switch test caps on top of the boiler are fitted correctly Operating for hot water but will not operate for central heating F Check that integral programmer is set to an on period and the function switch is set to auto If it still does not operate contact your installer F If fitted with an external programmer check that the central heating channel is set at an on pe...

Reviews: