B-1905-1(0)
INSTRUCTION SHEET - HS6B Series
Safety Switch
( 1 / 4 )
2016.08
1
Type
2
Specifications and Ratings
Ratings approved by safety agencies
(1) TÜV ra ing
AC-15 240V/0.75A
DC-13 250V/0.27A
DC-13 30V/2.3A
(2) UL
,
c-UL rating
C300 0.75A, 240V ac, Pilot Duty
Q300 0.27A, 250V dc, Pilot Duty
(3) CCC rating
AC-15 240V/0.75A
DC-13 30V/2.3A
(4) KOSHA rating
AC-15 240V/0.75A
DC-13 250V/0.27A
Install the safety switch on the immovable machine or guard,
and install the actuator on the movable door. Do not install both
safety switch and actuator on the movable door, otherwise
failure will occur.
Note : When inserting an actuator into the slot, make sure to
arrange the shapes in the same direction, as shown
on the right.
Actuator Mounting Reference Position
As shown below, the mounting reference position of the actuator inserted into the
safety switch is: The actuator stop touches the safety switch lightly.
Note: After mounting the actuator, remove the actuator stop from the safety switch.
Actuator Mounting Tolerance
• Mounting tolerance of the actua-
tor is 1.0mm from the center of
the actuator to up, down, right,
and, left.
• Make sure the actuator can be
inserted into the entry slot without
any issue.
Door Stop
Door Stop
Safety Switch
HS9Z-A61
Actuator
HS9Z-A65, A66
Actuator
Actuator Stop
Safety Switch
Actuator Stop
*
Make sure that a fast acting fuse for short-circuit protection trips before overheating of the wires.
Center
Safety Switch
±1.0mm
±1.0mm
3
Mounting Examples
2.5A
300V
4kV
2000m maximum
3 (Inside2)
-40 to +80°C (no freezing)
45 to 85%RH (no condensation)
-25 to +70°C (no freezing)
Low Voltage Directive, Machinery Direc ive
IEC60204-1/ EN60204-1
GS-ET-15, UL508, CSA C22.2 No.14 GB14046 5
EN ISO / ISO14119, IEC60947-5-1, EN60947-5-1
Resistive load(AC-12)
Inductive load(AC-15)
Resistive load(DC-12)
Inductive load(DC-13)
Weight
Short-Circuit Protec ive Device
Conditional short circuit current
Contact Resistance
Direct Opening Force
Direct Opening Travel
Electrical Durability
Mechanical Durability
B10d
Vibration Resistance
Shock Resistance
Electric Shock Protec ion Class
‹Ue, Ie›
( Reference Values )
Contact Ratings
Thermal Current ‹Ith›
Rated Insulation voltage ‹Ui›
Impulse wi hstand voltage ‹Uimp›
Condition
Operating
Applicable Directives
Standards for Use
Applicable Standards
Operating Temperature
Operating Humidity
Storage Temperature
Pollution Degree
Altitude
AC
DC
30V
-
-
2.5A
2.3A
125V
2.5A
1.5A
1.1A
0.55A
250V
1.5A
0.75A
0 55A
0 27A
Approx. 120g (at HS6B-03B01)
250V AC,10A fast acting type fuse
*
50A (250V)
300 mΩ maximum (Initial value, at cable length 1m)
60 N minimum
8 mm minimum
(1,200 operations / hour)
1,000,000 operations min. (AC/DC 24 100mA)
100,000 operations min. (AC-12 250V•1.5A)
1,000,000 operations minimum (GS-ET-15)
2,000,000 (EN ISO 13849-1 Annex C Table C.1)
Damage Limits: 30 Hz, half amplitude 1 5 mm
Operating Extremes: 5 to 55 Hz, half amplitude 0.5mm
Operating Extremes: 300m/s
2
, Damage Limits: 1,000m/s
2
Class
II
(IEC61140)
Minimum Radius of Hinged Door
When using the safety switch for a hinged door, the minimum radius of the applicable
door is shown in the following figures.
• When using L-shaped actuator (HS9Z-A62)
• When using angle adjustable actuator (HS9Z-A65/HS9Z-A66)
• When using angle adjustable actuator (HS9Z-A65/HS9Z-A66)
When the center of the hinged door is
on the extension line of the actuator
mounting surfase.
When the center of the hinged door
is on the extension line of the contact
surface of actuator and safety switch.
Note: The figures shown above are based on the condition that the actuator enters
and exits the actuator entry slot smoothry when the door is closed or opened.
Since there may be deviation or dislocation of the hinged door, make sure of
correct operation in the actual application before installation.
Door
Hinge
Door
Hinge
HS9Z-A62
230mm
Minimum Radius
Minimum Radius
230mm
Door
Hinge
Door
Hinge
Minimum
Radius
Minimum
Radius
160mm
160mm
(Horizontal Adjustment)
Door Hinge
Door Hinge
Door Hinge
Door Hinge
LABEL
LABEL
70mm
Minimum Radius
70mm
Minimum
Radius
50mm
Minimum Radius
50mm
Minimum
Radius
HS9Z-A65
HS9Z-A66
(Vertical Adjustment)
Door Hinge
Door Hinge
LABEL
Door Hinge
Door Hinge
LABEL
50mm
50mm
70mm
Minimum Radius
70mm
Minimum
Radius
HS9Z-A65
HS9Z-A66
Minimum Radius
Minimum
Radius
Interlocking device Type
/ the level of coded
Type 2 Interlocking device
/ low level coded actuator (EN ISO / ISO14119)
Operating Speed
Operating Frequency
0 05 to 1.0 m/s
1200 opera ions/hour
Degree of Protection
IP67 (IEC60529)
Confirm that the delivered product is what you have ordered.
Read his instruction sheet to make sure of correct operation.
In this operating instruction sheet, safety precautions are categorized to Warning and
Caution:
Warning notices are used to emphasize that improper operation may cause severe
personal injury or death.
Caution notices are used where inattention might cause personal injury or damage to
equipment.
INSTRUCTION SHEET
Original Instructions
Safety Switch
HS6B Series
S A F E T Y P R E C A U T I O N S
CAUTION
WARNING
Contact Configuration
11:1NC-1NO
02:2NC
12:2NC-1NO
03:3NC
HS6B-11B01 HS9Z-A61
Safety switch
Actuator
Cable Length
01:1m
03:3m
05:5m
61:Straight(Mainly for sliding doors)
62:L-shaped(Mainly for hinged doors)
65:Horizontal / Vertical Adjustment(Note)
66:Horizontal
/ Vertical Adjustment(Note)
Note : Select an actuator that moves in the direction required by the hinged door and
safety switch.
* In order to verify if the product
you are interested in is certified
with the S mark, please check
the following section on our
website: "List of type numbers
certified with the S mark"
※