background image

B-1905-1(0)

INSTRUCTION SHEET - HS6B Series 

Safety Switch

( 1 / 4 )

2016.08

1

Type

2

Specifications and Ratings

Ratings approved by safety agencies

(1) TÜV ra ing
  AC-15 240V/0.75A

  DC-13 250V/0.27A

  DC-13 30V/2.3A

(2) UL

c-UL rating

  C300  0.75A, 240V ac, Pilot Duty

  Q300  0.27A, 250V dc, Pilot Duty

(3) CCC rating
  AC-15 240V/0.75A

  DC-13 30V/2.3A

(4) KOSHA rating
  AC-15 240V/0.75A

  DC-13 250V/0.27A

Install the safety switch on the immovable machine or guard, 

and install the actuator on the movable door. Do not install both 

safety switch and actuator on the movable door, otherwise 

failure will occur.
Note : When inserting an actuator into the slot, make sure to 

arrange the     shapes in the same direction, as shown 

on the right.

Actuator Mounting Reference Position

As shown below, the mounting reference position of the actuator inserted into the 

safety switch is: The actuator stop touches the safety switch lightly.     
Note: After mounting the actuator, remove the actuator stop from the safety switch.

Actuator Mounting Tolerance

• Mounting tolerance of the actua-

tor is 1.0mm from the center of 

the actuator to up, down, right, 

and, left.

• Make sure the actuator can be 

inserted into the entry slot without 

any issue.

Door Stop

Door Stop

Safety Switch

HS9Z-A61

Actuator

HS9Z-A65, A66
Actuator

Actuator Stop

Safety Switch
Actuator Stop

*

 

Make sure that a fast acting fuse for short-circuit protection trips before overheating of the wires. 

Center

Safety Switch

±1.0mm

±1.0mm

3

Mounting Examples

2.5A

300V

4kV

2000m maximum

3 (Inside2)

-40 to +80°C (no freezing)

45 to 85%RH (no condensation)

-25 to +70°C (no freezing)

Low Voltage Directive, Machinery Direc ive

IEC60204-1/ EN60204-1

GS-ET-15, UL508, CSA C22.2 No.14 GB14046 5 

EN ISO / ISO14119, IEC60947-5-1, EN60947-5-1

Resistive load(AC-12)

Inductive load(AC-15)

Resistive load(DC-12)

Inductive load(DC-13)

Weight

Short-Circuit Protec ive Device

Conditional short circuit current

Contact Resistance

Direct Opening Force

Direct Opening Travel

Electrical Durability

Mechanical Durability

B10d

Vibration Resistance

Shock Resistance

Electric Shock Protec ion Class

‹Ue, Ie›

( Reference Values )

Contact Ratings

Thermal Current ‹Ith›

Rated Insulation voltage ‹Ui›

Impulse wi hstand voltage ‹Uimp›

Condition

Operating 

Applicable Directives

 

Standards for Use

Applicable Standards

Operating Temperature

Operating Humidity

Storage Temperature

Pollution Degree

Altitude

AC

DC

30V 

  

 

  

 

 2.5A 

 2.3A 

  

125V 

 2.5A 

 1.5A

 1.1A

0.55A

  

250V 

 1.5A 

0.75A

0 55A

0 27A

Approx. 120g (at HS6B-03B01)

250V AC,10A  fast acting type fuse 

*

50A (250V)

300 mΩ maximum    (Initial value, at cable length 1m)

60 N minimum

8 mm minimum

(1,200 operations / hour)

1,000,000 operations min.  (AC/DC 24 100mA)

100,000 operations min. (AC-12 250V•1.5A)

1,000,000 operations minimum (GS-ET-15)

2,000,000 (EN ISO 13849-1 Annex C Table C.1)

Damage Limits: 30 Hz, half amplitude 1 5 mm

Operating Extremes: 5 to 55 Hz, half amplitude 0.5mm

Operating Extremes: 300m/s

2

, Damage Limits: 1,000m/s

2

Class 

II

  (IEC61140) 

Minimum Radius of Hinged Door

When using the safety switch for a hinged door, the minimum radius of the applicable 

door is shown in the following figures.

• When using L-shaped actuator (HS9Z-A62)

• When using angle adjustable actuator (HS9Z-A65/HS9Z-A66)

• When using angle adjustable actuator (HS9Z-A65/HS9Z-A66)

When the center of the hinged door is 

on the extension line of the actuator 

mounting surfase.

When the center of the hinged door 

is on the extension line of the contact 

surface of actuator and safety switch.

Note: The figures shown above are based on the condition that the actuator enters 

and exits the actuator entry slot smoothry when the door is closed or opened. 

Since there may be deviation or dislocation of the hinged door, make sure of 

correct operation in the actual application before installation.

Door

Hinge

Door

Hinge

HS9Z-A62

230mm

Minimum Radius

Minimum Radius

230mm

Door

Hinge

Door

Hinge

Minimum

Radius

Minimum

Radius

160mm

160mm

(Horizontal Adjustment)

Door Hinge

Door Hinge

Door Hinge

Door Hinge

LABEL

LABEL

70mm

Minimum Radius

70mm

Minimum

Radius

50mm

Minimum Radius

50mm

Minimum

Radius

HS9Z-A65

HS9Z-A66

(Vertical Adjustment)

Door Hinge

Door Hinge

LABEL

Door Hinge

Door Hinge

LABEL

50mm

50mm

70mm

Minimum Radius

70mm

Minimum

Radius

HS9Z-A65

HS9Z-A66

Minimum Radius

Minimum

Radius

Interlocking device Type

 / the level of coded

Type 2 Interlocking device

/ low level coded actuator (EN ISO / ISO14119)

Operating Speed

Operating Frequency

0 05 to 1.0 m/s

1200 opera ions/hour

Degree of Protection

IP67 (IEC60529) 

Confirm that the delivered product is what you have ordered. 

Read  his instruction sheet to make sure of correct operation. 

In this operating instruction sheet, safety precautions are categorized to Warning and 

Caution:

Warning notices are used to emphasize that improper operation may cause severe 

personal injury or death.

Caution notices are used where inattention might cause personal injury or damage to 

equipment.

INSTRUCTION SHEET

Original Instructions

Safety Switch

HS6B Series

S A F E T Y   P R E C A U T I O N S

CAUTION

WARNING

Contact Configuration
 11:1NC-1NO

 02:2NC

 12:2NC-1NO

 03:3NC

HS6B-11B01 HS9Z-A61

Safety switch

Actuator

Cable Length
 01:1m

 03:3m

 05:5m

61:Straight(Mainly for sliding doors)

62:L-shaped(Mainly for hinged doors)

65:Horizontal / Vertical Adjustment(Note)

66:Horizontal

 

/ Vertical Adjustment(Note)

Note :  Select an actuator that moves in the direction required by the hinged door and 

safety switch.

* In order to verify if the product 

you are interested in is certified 

with the S mark, please check 

the following section on our 

website: "List of type numbers 

certified with the S mark"

Summary of Contents for HS6B Series

Page 1: ...00 000 operations minimum GS ET 15 2 000 000 EN ISO 13849 1 Annex C Table C 1 Damage Limits 30 Hz half amplitude 1 5 mm Operating Extremes 5 to 55 Hz half amplitude 0 5mm Operating Extremes 300m s2 Damage Limits 1 000m s2 Class II IEC61140 Minimum Radius of Hinged Door When using the safety switch for a hinged door the minimum radius of the applicable door is shown in the following figures When us...

Page 2: ... not fasten and loosen the conduit at the bottom of the safety switch When wiring make sure that liquid such as water and oil dose not intrude from the tip of cable When bending cable at wiring secure the cable radius of 40mm at the minimum Be sure to use the dedicated actuator only and do not operate the HS6B safety switch with anything other than the dedicated actuator Otherwise the safety of th...

Page 3: ...S AF series manufactured by IDEC CORPORATION Example of a circuit diagram for Safety Category 4 attainable PL e Example of a circuit diagram for Safety Category 3 attainable PL d Condition 1 To apply he fault exclusion of mechanical structural parts including he actuator Make sure to use the product within the product specification range described in this manual and the version of the manual provi...

Page 4: ... Angle Adjusting Screw M3 Hexagon Socket Set Screw Angle Adjusting Screw M3 Hexagon Socket Set Screw Note HS9Z A65 and HS9Z A66 are different in he insertion direction of the metal key 180 Factory defalut 3 Vertical Adjustment Angle Adjusting Screw M4 Holes Base Base Actuator Stop 2 M3 Hexagon Socket Set Screw Factory defalut 3 9 Precaution for Disposal Dispose of HS6B Safety Switch as an industri...

Reviews: