Do not connect the product to a power supply outside the rated power supply
voltage range or to an AC power supply. Otherwise there is a risk of explosion
or burnout.
・
Mistakenly wiring the product may cause the internal circuit to be damaged.
Wire the input and output circuits by referring to "Input and output circuit
connection example" in article 6. This product is not equipped with a protection
circuit for a reversed power supply connection, so there is a risk of damage
when the power supply connection is reversed. Use extreme caution when
connecting the power supply.
・
Avoid parallel wiring of the product's wires in the same conduit or duct with high
voltage lines or power lines (inverter power lines in particular) as this may
cause malfunction or damage due to the effect of induction noise.
・
If the wires are long and when there is a risk of being affected by power
sources or solenoids, independently wire the product as a general rule.
・
Avoid installing or using the product in the following locations as there is a risk
of malfunction or damage.
1) Near induction equipment or heat sources
2) Locations with many vibrations or shocks
3) Dusty and dirty locations
4) In an atmosphere with hazardous gases such as sulfidizing gas
5) Locations in direct contact with water, oils, or chemicals
6) Outdoors
・
This product is not an explosion-proof product. Confirm that explosion-proof
capabilities are not required when installing the product.
・
This product is not designed for use in medical equipment, nuclear power,
railways,aircraft, passenger vehicle equipment, or similar applications
requiring a high degree of reliability and safety. Do not use the product for
these applications.
・
When using this product in a system that may impact human life, such as in
the management of chemicals, take the utmost care with a redundant design
and safety design so that there is no possibility of impacting human life when
data is mistaken.
・
Do not modify , disassemble, or repair this product. There is a risk of serious
ac cidents such as electric shock, damage, fire, malfunction, and other heave
accident.
・
Do not directly look at the reading window (transparent section) or expose
any person to it while the LED is illuminated (performing reading operation).
There is a risk of danger to the eyes.
・
This product is for general electronic equipment. Do not use it for applications
where there is a direct threat to the body or to human life due to malfunction or
failure.
・
Always turn off the power supply before wiring, maintaining, and inspecting the
product. Otherwise there is a risk of electric shock or failure.
INSTRUCTION SHEET
WB2F 2D Code Scanner
SAFETY PRECAUTIONS
B-
1945(0)
Confirm that the delivered product is what you have ordered. Read this
instruction sheet to make sure of correct operation. Make sure that the
instruction sheet is kept by the end user.
Caution notices are used where inattentionmightcausepersonalinjuryor
damage to equipment.
In this operation instruction sheet, safety precautions are categorized in order
of importance to Warning and Caution:
Warning notice are used to emphasize that improper may cause severe
personal injury or death.
FCC Regulations
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
when
the equipment is operated in a commercial environment. This equipment
generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in whitch case the user
will be required
to correct the interference at his own expense.
・
The power supply reset time is less than 5 seconds, so use the product 5 seconds
after turning the power on.
・
When the load and the unit are connected to different power supplies, always
turn on the unit's power supply first.
・
Install the product so that the reading window is not directly exposed to
sunlight or fluorescent light.
■
Cleaning the reading window
If dust, dirt, or water drops gets on the reading window (transparent section)
or if it gets scratched, this will affect code reading performance.
Periodically inspect the reading window (red transparent section) to see if there
is any dust on it, and when you find dust, clean it off.
・
To clean the reading window, blow off dust/dirt with an airbrush, and then
gently wipe it off with a soft-tipped item such as a cotton swab.
・
Reading performance may drop when the reading window is subject to
moisture, so wipe it off with a soft cloth to use the product. It may affect the
material of the optical section, so do not use chemicals on it.
■
Cleaning the scanner unit
Wipe off any dirt on the scanner unit with a soft, dry cloth.
・
Do not use chemicals. This may alter the case or strip the paint.
・
When the dirt is particularly bad, wipe it off with a cloth soaked in a neutral
detergent diluted with water and wrung out thoroughly, and then wipe with a
soft, dry
cloth.
5
Installing the driver
・
Using the USB interface
To use the USB interface, you must install the dedicated Active USB-COM
port drive (virtual COM port driver) on the host computer. For details on the
installation procedure, refer to the
WB2F Userʼs Manual
.
The manual can be downloaded from the dedicated site on the IDEC
website. If using this product in an environment where the IDEC homepage
cannot be accessed, please contact IDEC sales representatives.
6
Wiring, terminal layouts
□
Input and output circuit connection example
・
External output 0 to 3
・
External input 0, 1
□
Terminal layout of connectors
・
DIN connector
・
USB connector ( Mini-B )
Conductor
color
Signal
name
Function
1
OUT0
External output 0
OUT1
External output 1
3
OUT2
External output 2
4
OUT3
5
+5V
DC power
6
TXD
RS-232 tranmission data
7
IN0
External input 0
8
External input 1
0V
Power supply- (combined SG)
11
RXD
CTS
RTS
RS-232 receive data
Pin number
Signal name
Function
1
VBUS
2
D-
Data-
3
D+
Data+
4
NC
Ground
No connection
Note: USB connector is for maintenance. For the RS-232 signals, extend
the cable with a AWG28 or thicker cable with due consideration the drop
in the power supply voltage. If the total cable length exceeds 2.8 m,
this may affect noise resistance.
Note: For the RS-232 interface, connect a shield of cable to ground or 0V
when the communication performance is not good by the noise environment.
3
Mounting
・
The tightening torque for the product mounting screws is 0.4 to 0.5 N
・
m.
・
Do not overtighten the mounting screws or hit the product with a hammer or
the act that requires excessive stress on the root part of the cable (strongly
pull or bend, etc.) the protective construction will be damaged.
・
Do not use the included mounting screws when mounting the product to a
plate with a thickness greater than 2.3 mm.
・
Ensure that the screw depth of the mounting screw is 3 to 5 mm.
・
When mounting with except using the included mounting bracket, the maximum
mounting hole diameter should be
φ
3.4mm.
・
Mount the product so that the barcode or 2D code skew angle is that shown
in the following diagram. Reading performance drops drastically if the barcodes
are face-to-face with the optical axis.
8
Reading range
Install the product by referring to Appendix A of reading range.
This reading range is a representative example measured under the following
measurement conditions.
・
IDEC standard barcode or 2D code
・
Skew:15°, pitch: 0°, tilt: 0°
・
Ambient illumination: 300 to 500 lx
9
Part names and dimension
(Unit:mm )
10
Precautions when discarding the product
・
When discarding the product, handle it as industrial waste.
http://www.idec.com
201
7
.
2
1
Type number
B
:
RS-232
WB2F-100S1B Communication interface
If you want to initialize the product, read the above barcode in maintenance
mode. All the settings will be restored to the factory defaults.
Turn on this product with the operation button pushed and continue holding the
READ / ENTER
button for 5 seconds to switch to maintenance mode. When
maintenance mode starts, the three status LEDs will all flash. When initialization
is complete, the three status LEDs will turn off and normal operation mode will
be restored.
11
Canadian Department of Communications Compliance Statement
・
CAN ICES-3(A) / NMB-3(A)
Manufacturer
:
IDEC CORPORATION
2-6-64, Nishimiyahara, Yodogawa-ku,
Osaka 532-0004, Japan
EU Authorized Representative:
IDEC Elektrotechnik GmbH
Heselstuecken 8, 22453 Hamburg, Germany
3
1
5
6
9
8
10
40.0
24.0
1.0
17.0
9.4
18.5
10.7
Optical Center
Emitter LED x4
4.9
19.2
36.5
33.0
32.0
0.4
19.5
Cable Length
: 2m
MAX
6.0
2-M3
length 5mm or less
(Mounting screw holes)
10.5
10.7
6.2
Power LED
USB port
Status LED
SELECT button
TCP9386
READ / ENTER button
8
Initialization
7
Other important information
11
2
10
12
13
9
5
GND
IN1
9.4mm
-15 to -60°
(50 to 180mm)
15 to 60°
model
Rated power supply voltage
Consumption Curren
Operation Button
Readin
distance
Field of view
Number of digits
to be read
PCS
Minimum resolution
Imaging element
Frame rate
Communication
interface
External input
External output
Dielectric strength
Anti-ESD
Ambient usage temperature
Ambient usage humidity
Ambient usage illumination
Ambient usage temperature
Certified standards
WB2F-100S1B
5VDC±0.25V *1
500mA or less (peak 1A or less)
50 to 180mm (narrow bar size 0.5mm) *2
100
mm
70mm×50mm (at focalpoint)
Barcode
2D code
0.45 or higher *2
0.127
mm
High brightness red LED
CMOS image sensor with grobal shutter
Quad-VGA (1280*960)
36fps
720
p
(1280*720)
40fps
RS-232(600
~
115,200bps)
*3
WVGA(800*480)
60fps
Serial I/F
USB
13pin DIN
type
connector 2m
2 circuits
Non-voltage contact(Low active)
Voltage input(VIL
:
0-1.0V, VIH
:
4.0-VCC)
4 circuits
NPN open collector (sink)
Max. rating 26.4V DC
,
50mA
500V AC (live part-dead part, 1minute)
Contact ±4kV
,
air ±8kV (IEC61000-4-2)
0 to 45
℃
(no freezing)
30 to 85%RH (no condensation)
10,000lx or lower (under sunlight)
6,000lx or lower (under incandescent light)
2,000lx or lower (under fluorescent light)
-20 to 60
℃
(no freezing)
Approx. 150g
IP65
Barcode
2D code
Light source
Connection type
Weight
Protective construction
Symbols
to be read
USB2.0 Full-speed 12Mbps (virtual COM) *4
EAN-13/8(including addon), UPC-A/E0/E1(including addon),
CODE39, Codabar(=NW7), Interleaved 2of5(=ITF),
Standard 2of5(=Industrial 2of5), Matrix 2of5,
Chinese Post Matrix, COOP 2of5, SCODE, Code93,
Code128, GS1-128(formerly
:
EAN-128), MSI/Plessey,
Italian Pharm(Code32), CIP39, Tri-Optic, TELEPEN,
Code11, GS1 Databar(formerly:RSS)(Omni-directional,
Truncated, Limited, Expanded), GS1 Databar Stacked
(Omni-directional,Expanded)
, IATA 2of5
UL/c-UL Listing
, CE marking(self declared), VCCI(Report
of Compliance), FCC(Verification), ICES-003(self declared)
QR
Code
/ GS1 QR Code, Micro QR Code,
DataMatrix(DataCode) / GS1 DataMatrix,
PDF417, Micro PDF417
GS1 composite(CC-A, CC-B, CC-C), Japan Postal
Equipped on unit (tactile switch) x 2
50 to 150mm (cell size 0.5mm) *2
64 digits max
7,089 digits max
Barcode
2D code
NC
External output 3
No connection
RS-232 control signal
RS-232 control signal
Bus power
9
Usage precautions
4
Focal point
*1 Use only a Listed Power Supply with an output rated 5Vdc and marked LPS or NEC Class 2
for use the WB2F as UL Listing product
*2 By IDEC standard barcode or 2D code
*3 RS232 setting parameters of factory setting are baud rate 9,600bps, data size 8bit, 1 stop bit,
even parity bit, no flow control
*4 For maintenance interface
( incompartible USB bus power )
2
General specifications
2
USB connector
5 1
DIN connector
Load
24VDC
(26.4VDCmax.)
OUT
0V
Non-vo
ltage contact
5V
R
R
Mai
n circuit
Mai
n circuit
Product mounting screws (included)
SEMS M3 x 6mm(2 screws)
Mounting Bracket (included)
IN
WB2F
Position LED
Optical axis