29
37
29
92
0-
D
Quick
Guides
WEEE
Head office :
2, place Samuel de Champlain - 92400 Courbevoie
Detailed instructions are available at
Des instructions détaillées sont disponibles sur
El detalle de las instrucciones está disponible en
https://biometricdevices.idemia.com
Technical Support and Hotline
USA & Canada
Mail: support.bioterminals.us@idemia.com
Tel: +1 888 940 7477
LATAM (Latin America)
Mail: support.bioterminals.us@idemia.com
Tel: +1 714 575 2973
EMEA (Europe, Middle-East, Africa)
Mail: support.bioterminals@idemia.com
Tel: +33 1 30 20 30 40
APAC (Asia & Pacific)
Mail: support.bioterminals.in@idemia.com
Tel: +91 8929 159 665
India
Mail: support.bioterminals.in@idemia.com
Tel: +91 1800 120 203 020
COPYRIGHT © 2021, IDEMIA
Regulatory, safety and environmental notices
Products bearing the CE marking comply with one or more of the
following EU Directives as may be applicable:
Radio Equipment Directive (RED) 2014/53/UE
RoHS Directive 2011/65/EU.
Compliance with these directives is assessed using applicable European
Harmonised Standards.
The installation of this product should be made by a qualified service
Person and should comply with all local regulations.
It is strongly recommended to use a class II power supply at 12V-24V
and 2.5 A. min (at 12V) in conformity with Safety Electrical Low Voltage
(SELV). The AC power supply cable length should not exceed 10
meters.
This system must be installed in accordance with the National Electrical
Code (NFPA 70), and the local authority having jurisdiction.
This product is intended to be installed with a power supply complying
with IEC60950-1, in accordance with the NEC Class 2 requirements; or
supplied by a listed IEC60950-1 external Power Unit marked Class 2,
Limited Power source, or LPS and rated 12VDC, 2.5 A minimum or
24VDC, 1.25 A minimum.
In case of building-to-building connection it is recommended to connect
0V to ground. Ground cable must be connected with the terminal block
Power Ground.
Note that all connections of the Morpho
Wave
Compact terminal
described hereafter are of SELV (Safety Electrical Low Voltage) type.
This symbol means do not dispose of your product with your other
household waste. Instead, you should protect human health and the
environment by handing over your waste equipment to a designated
collection point for the recycling of waste electrical and electronic
equipment.
상호명 : IDEMIA Identity & Security France
기자재의명칭명칭(모델명) : RFID용 무선기기(13.56MHz 주파수대역) (MPH-AC004A)
제조연월 : 2020년 월
제조자/제조국가 : IDEMIA Identity & Security France / France
식별부호 : R-R-Ide-MPHAC004A
Status LED
Optional
Wi-Fi™
Interface
Speaker
4.3" WVGA
touchscreen
LCD
Contactless
Card area
Microphone
Hand
proximity
sensor
Contactless
biometric
sensor
Models:
Morpho
Wav
e Compact MD
(MPH-AC004A)
Morpho
Wav
e Compact MDPI
(MPH-AC004B)
Morpho
Wav
e Compact MDPI-M (MPH-AC004C)
90
0
-
1
0
00
m
m
Access
Control Line
Security
Destructive
Attack
Endurance
Stand-by
Power
Conditions
Level I
Level I
Level IV
Level I
NA
UL294 Performance levels
Morpho
Wave
Compact
Quick Installation Guide
100mm
11
2m
m
41mm
25
m
m
Φ
=
4
m
m
Φ
=
4
m
m
Φ
=
4
m
m
Φ
=
4
m
m
SCALE 1:1