Fluid Management 

Technical Support 

 

AT1500 Canister Replacement

 

PRODUCT(S) 

AT1500 

PURPOSE  

This instruction is for all customers using Fluid Management’s ColorPro 4.x. software. 
Follow  this  procedure  if  the  pump  or  agitation  motor  has  failed  or  the  canister  is 
malfunctioning.  

INSTRUCTIONS 

1.  Unplug dispenser power cord from outlet on rear of machine 

2.  Locate the closest access panel to the canister requiring replacement 

3.  Remove the mounting screws 

4.  Place the access panel to the side and out of the way 

5.  Locate the canister and pump assembly to be replaced 

6.  Disconnect the 3 different wire harness connectors plugged to the DVX pump and 

agitation motor 

a.  Caution: do not pull on the wires; instead, pull on the plastic connector 

housing. Use pliers or a flat head screw to remove connector B 

7.  Remove the quick disconnect fitting from the DVX pump nipple 

a.   To remove the fitting, compress the inner collet towards the fitting. While 

holding the collet inward, pull on the connector to remove it from the pump 

b.  NOTE: the tubing has colorant and it will drain. Prepare a container to catch 

the colorant 

8.  Open the top lid and remove defective canister assembly 

9.  Push up on the base of the canister to remove canister 