CTB-11
AT1500 Canister
Replacement
6/20/19
Original Release
Reformatted document, re-released.
Fluid Management
Technical Support
AT1500 Canister Replacement
PRODUCT(S)
AT1500
PURPOSE
This instruction is for all customers using Fluid Management’s ColorPro 4.x. software.
Follow this procedure if the pump or agitation motor has failed or the canister is
malfunctioning.
INSTRUCTIONS
1. Unplug dispenser power cord from outlet on rear of machine
2. Locate the closest access panel to the canister requiring replacement
3. Remove the mounting screws
4. Place the access panel to the side and out of the way
5. Locate the canister and pump assembly to be replaced
6. Disconnect the 3 different wire harness connectors plugged to the DVX pump and
agitation motor
a. Caution: do not pull on the wires; instead, pull on the plastic connector
housing. Use pliers or a flat head screw to remove connector B
7. Remove the quick disconnect fitting from the DVX pump nipple
a. To remove the fitting, compress the inner collet towards the fitting. While
holding the collet inward, pull on the connector to remove it from the pump
b. NOTE: the tubing has colorant and it will drain. Prepare a container to catch
the colorant
8. Open the top lid and remove defective canister assembly
9. Push up on the base of the canister to remove canister