background image

 

International Technologies & Systems Corporation 

10721 Walker Street, Cypress, CA 90630-4720; Tel: (714) 761-6368; Fax: (714) 761-8880 

www.idtechproducts.com

 

 
 
 

 

80140502-001 

 

User Manual 

 

Spectrum Pro 

 

PCI PTS 4.X Hybrid Insert Reader  

 

USB / RS232 Interface 

 

 

 
 
 
 
 
 
 
 
 

  

 

 

80140502-001 
Rev. A   5/17/2017 
 

 

Summary of Contents for 80140502-001

Page 1: ...ms Corporation 10721 Walker Street Cypress CA 90630 4720 Tel 714 761 6368 Fax 714 761 8880 www idtechproducts com 80140502 001 User Manual Spectrum Pro PCI PTS 4 X Hybrid Insert Reader USB RS232 Interface 80140502 001 Rev A 5 17 2017 ...

Page 2: ... or liability for any unintentional errors or inaccuracies that may appear in this document Except as permitted by such license no part of this publication may be reproduced or transmitted by electronic mechanical recording or otherwise or translated into any language form without the express written consent of ID TECH ID TECH and ViVOpay are trademarks or registered trademarks of ID TECH Warranty...

Page 3: ...ion History Revision Date Description of Changes By 50 2 23 2015 Preliminary Version CH 51 3 10 2015 Revise low power mode CH 52 10 27 2015 Expanded description of Features and Benefits Default sleep timeout value is 120 seconds KT A 5 17 2017 Update status LED table add low power mode details correct various items KT ...

Page 4: ...2 FEATURES AND BENEFITS 5 3 ABBREVIATIONS 5 4 APPLICABLE DOCUMENTS 6 5 FRONT AND BACK VIEW 6 6 SPECIFICATIONS 7 6 1 SUPPLY POWER 7 6 2 RELIABILITY AND ENVIRONMENT 8 6 3 ENVELOPE DRAWING 9 6 4 1 RS232 COMMUNICATION SETTINGS 10 7 MOUNTING INSTRUCTIONS 11 8 LED MANAGEMENT 12 8 1 FRONT LED STATUS 12 8 2 DIAGNOSTIC LED STATUS 12 9 OPERATION PROCEDURE 15 ...

Page 5: ...evelopers can also communicate with Spectrum Pro directly using UART and or USB HID For details see the P N 80140505 001 Spectrum Pro Low Level API Manual This manual contains the complete firmware level API guide for controlling Spectrum Pro directly The low level API manual can be downloaded from https atlassian idtechproducts com confluence display KB Spectrum Pro downloads 2 Features and Benef...

Page 6: ...tems Corp All rights reserved Page 6 of 15 4 Applicable Documents ISO IEC 7813 Identification cards Physical Characteristic ISO IEC 7811 Identification cards Recording Techniques Magnetic Stripe 80140505 001 ID Tech Spectrum Pro Low Level API Manual 5 Front and Back View ...

Page 7: ...Sleep mode current 20 uA Stop mode current with UART wakeup 16 uA with no UART wakeup 10 uA Reader falls into sleep mode after it is idle for specified time duration The default time duration is 120 seconds This can be adjusted or even disabled Reader can be commanded to go to Stop mode which is a special very low power consumption mode Reader can wake up from Sleep mode by card insertion or via U...

Page 8: ...ic Head Life 1 000 000 passes minimum Rail and Cover Life 1 000 000 passes minimum Environmental Temperature range Operating 13º F to 158º F 25º C to 70º C non condensing Storage 40º F to 176º F 40º C to 80º C non condensing Relative humidity 10 to 95 non condensing ESD 6kV contact and 12 kV air discharge per ID TECH ESD testing procedure without permanent damage ...

Page 9: ...Spectrum Pro User Manual Copyright 2017 International Technologies Systems Corp All rights reserved Page 9 of 15 6 3Envelope Drawing ...

Page 10: ... rights reserved Page 10 of 15 6 4 1 RS232 Communication Settings Parameter Specification Transmission protocol Asynchronous Communication method Full Duplex Start bit l bit Data length 8 bits Bit7 MSB Bit0 LSB Parity None Stop bit l bit Transmission speed Baud rate 115200 bps default ...

Page 11: ...ies Systems Corp All rights reserved Page 11 of 15 7 Mounting Instructions The reader can be mounted in either a horizontal or vertical orientation The removal detection points must be pressed down when the unit is mounted Please refer to the mounting drawing below ...

Page 12: ... and the ICC powered off The user can remove the smart card 8 2 Diagnostic LED Status The LED on the back of Spectrum Pro can be used for diagnostic purposes LED status 1 Off 2 Solid No communication with its host 3 Flashing 1 sec on 1 sec off Communicating with its host LED Colors Amber Reader requires on site service actions Green Reader is ready to read cards Red Reader needs to be sent back to...

Page 13: ...he front removal detection buttons left side of front bezel are not depressed If this possibility is ruled out check host connectivity Check that the removal detection button is fully depressed Check the communication cable and if host is running 4 Solid Green Solid Amber Power on First restart and no command sent In not ready state and waiting for host to communicate RFU 5 RFU RFU RFU RFU 6 Flash...

Page 14: ...ivate the reader 10 Solid Amber Solid Red Reader has no communication with its host and the crypto driver is not functioning Crypto MCU is lost or certificates are invalid may be tampered Dismount the reader and send it back to its manufactory 11 Flashing Amber Reader is communicating with its host and the crypto driver is not functioning Crypto MCU is lost or certificates are invalid may be tampe...

Page 15: ...s Systems Corp All rights reserved Page 15 of 15 9 Operation Procedure A chip card should be inserted with chip side facing up as shown below A magstripe card should be inserted with magstripe facing down and to the right side of the reader Please see pictures below ...