background image

 

 

 

 

 

 

 

 

BTScan

TM

 

Barcode Scanner

 

User’s Manual

80126502-001  rev.A 

Summary of Contents for BTScan

Page 1: ...BTScanTM Barcode Scanner User s Manual 80126502 001 rev A ...

Page 2: ... Customer Configuration 8 9 19 20 21 Delay between block and character 10 Keyboard layout Caplock Mode Numeric Key 22 11 RS232 Baud rate Data bits Parity 23 12 RS232 Stop bit Handshaking ACK NAK Flow Control BCC 24 13 14 Wand Emulation parameter setting 25 SETTING GROUP GROUP1 14 SYMBOLOGY FORMATTING GROUP15 32 FULL ASCII CODE39 TABLE FUNCTION KEY TABLE GROUP33 47 APPENDIX 28 China postcode Toshib...

Page 3: ...ble needs to match the interface 1 Follow the procedures for these settings at the appropriate pages 2 The scanner will beep three times for an incomplete setting 3 Scan RESET to try a setting again 1 Preamble Postamble Group4 page 14 2 Accuracy Adjustment Group5 page 15 3 Customer ID Configuration Group 8 9 page 18 19 4 Min Max Length Group 17 18 19 20 21 22 25 5 ABC Codabar Group 22 23 6 CX Coda...

Page 4: ...of the kind of device chosen on the scanner NOTES 1 All cloning strings are upper case 2 All cloning strings printed on labels should be the same as those on the monitor sequentially from first to last 3 Cloning mode works in Word Note Pad only 4 Never edit the data on the first row A017 It is an entry command for cloning 5 The cloning string s length can be adjusted by combining multiple strings ...

Page 5: ...ammed with the same settings as the first wand Be sure to scan from the first row to the second and so on sequentially top to bottom A017 0604 5A025F04 A017 0604 5A02 5F04 4 4 4 4 Dot A017 06045A02 5F04 12 4 Dot A017 0604 5A025F04 A017 0604 5A02 5F04 Wrong Setting The string consists of 4 Dots located at the beginning of second row do not break the into multiple strings Wrong Setting The string le...

Page 6: ...r adaptor to the cable 4 Restart the computer 5 Plug the power adaptor into a power outlet 6 The scanner will beep 7 Set the scanner to RS 232 interface by referring to GROUP 1 page 9 Interfaces Selection 8 Set RS 232 protocol Baud Rate Stop Bits Handshaking Data Bits and Parity 9 Scan a bar code to confirm that data shows on the monitor NOTES 1 Before plugging the power adaptor into the scanner b...

Page 7: ...to GROUP 1 Interfaces Selection 5 Scanner will beep to confirm the setting 6 Scan a bar code to confirm that data shows on the monitor USB INTERFACE HOW TO CHANGE A CABLE The scanners are designed to switch easily between interface options To switch from one interface to another the appropriate cable must be installed To change a cabl simply follow these steps 1 To release the cable insert a pin o...

Page 8: ...roup 33 44 page51 62 Step 4 Scan PREAMBLE or POSTAMBLE Min Length Max Length Step 1 Scan MIN LENGTH or MAX LENGTH Step 2 Scan two digits from Group 41 page59 Step 3 Scan MIN LENGTH or MAX LENGTH Accuracy Adjustment Step 1 Scan ACCURACY ADJUSTMENT Step 2 Scan one digit from GROUP 5 page16 Step 3 Scan ACCURACY ADJUSTMENT Customer Configuration ID Example Code 39 Step 1 Scan CODE 39 SET ID from Group...

Page 9: ...ensure the correct computer type is set when the scanner is attached to a new host computer If set to Notebook the scanner will operate with no external keyboard Caution This scanner is designed to switch easily between interface options To switch from one interface to another the appropriate cable must be installed After changing to a new cable be sure to reset the interface setting as appropriat...

Page 10: ... TOGGLE MODE F003 F007 AUTO SENSING MODE CCD This function works like Trigger Mode but the scanner beeps to indicate a good read The LED is always on when the trigger is pressed The LED will go off if no bar code has been detected after 60 seconds The LED will light when the trigger is pressed The LED will go off when the trigger is released The LED is on steady if a bar code is close to the scann...

Page 11: ... LED Red LED Red LED Green LED Beeper Remark Remark Initializing Successful Connection Barcode Scan w o Connection Successful Barcode Scan Low Power Power Off or Standby Charging Successful Connection Full Charge Unsuccessful Pincode Setup Flash Flash 1 Flash Flash Flash Flash On On On On 4 hours to fully charge Power adaptor needed See Power Off Timeout Scan Pincode Stop and retry 1 long beep 2 b...

Page 12: ...11 beeps 4 Select Wireless Scanner from discovered device list 5 The Bluetooth application may prompt you to scan a pincode see PINCODE SETUP section the on next page 6 The scanner will beep twice to verify the connection E031 Disconnect SMARTPHONE CONNECTION E044 Android iOS Apple 1 Pair with the scanner via BT mode SPP 2 Install Bluetooth Connect apk and enter the program 3 Enable BluetoothConne...

Page 13: ...C BARCODES 1 2 3 4 5 6 7 8 9 0 Pincode Start E032 STEP 1 E033 Pincode Stop STEP 4 TX Enter STEP 3 Scan numeric barcodes see NUMERIC BARCODES below based on the pincode generated by the Bluetooth application STEP 2 APPENDIX PINCODE SETUP ...

Page 14: ...019 BEEP HIGH F020 BEEP LOW HIGH F022 BEEP LOW BEEP OFF F012 F021 BEEP HIGH LOW F018 BEEP MEDIUM GROUP 3 CHECK VERSION BEEP TONE TERMINATOR BEEP TONE MODE CHECK VERSION TERMINATOR 2 7KHz 2 1KHz 1 For the Keyboard Wedge interface the default terminator is CR 2 For the USB interface the default terminator is CR 3 For the RS232 interface the default terminator is CR LF NOTES ...

Page 15: ...a string of up to 16 characters added to the beginning of a scanned barcode 2 A POSTAMBLE is a string of up to 16 characters added to the end of a scanned barcode 3 Default value for both None Preamble Code ID Bar Code Postamble Set PREAMBLE String as POSTAMBLE String as STEP 1 Scan CLEAR PRE POSTAMBLE STEP 2 Scan PREAMBLE STEP 3 Scan twice from FULL ASCII Table STEP 4 Scan PREAMBLE STEP 5 Scan PO...

Page 16: ...ep etc scan RESET to start again ACCURACY ADJUSTMENT Accuracy Adjustment assures a more reliable decoded output Enabling the feature and setting a number from 1 to 9 subjects the decoded output a higher standard of accuracy The higher the number the greater the accuracy SETTING PROCEDURE 1 Scan ACCURACY ADJUSTMENT 2 Scan one digit 1 9 from barcode menu above 3 Scan ACCURACY ADJUSTMENT ...

Page 17: ...IVE LABEL ENABLE D021 ENABLE NEGATIVE LABEL POSITIVE NEGATIVE ENABLE D022 GROUP 6 LABEL TYPE POSITIVE NEGATIVE ENABLE AND DISABLE CODE ID LABEL TYPE POSITIVE NEGATIVE ENABLE CODE ID DISABLE CODE ID NOTES 1 Only ONE code ID will be sent 2 The code ID is located at the position before the bar code data and after the preamble EXAMPLE 1 Preamble 145287 2 Code ID enable AIM ID 3 Bar code symbologies EA...

Page 18: ...s Factory ID AIM ID new Symbologies Factory ID AIM ID new EAN 128 Code 128 EAN8 2 5 OFF EAN8 2 ON EAN8 5 ON UPC E 2 5 OFF UPC E 2 ON UPC E 5 ON UPC A 2 5 OFF UPC A 2 ON UPC A 5 ON EAN 13 2 5 OFF EAN 13 2 ON EAN 13 5 ON Code 93 Code 11 disable CDV Code 11 send one CD Code 11 send two CD Code 11 not send CD Telepen ASCII Telepen Numeric J U L F A E S K T C1 C0 E4 E4 E4 E0 E3 E3 E0 E3 E3 E0 E3 E3 G0 ...

Page 19: ...12 GROUP 8 CODE ID CONFIGURATION SET ID P001 EAN 13 Set ID EAN 8 Set ID UPC E Set ID UPC A Set ID Code 39 Set ID Code 93 Set ID Codabar Set ID IATA Set ID Code 128 Set ID EAN 128 Set ID Telepen Set ID Code 11 Set ID Code 32 Set ID China Post Code TOSHIBA Code Set ID ...

Page 20: ...If you make a mistake forget a step etc scan RESET to start again GROUP 9 CODE ID CONFIGURATION SET ID MSI Code Set ID UK Plessey Set ID Matrix 2 of 5 Set ID Interleaved 2 of 5 Set ID Industrial 2 of 5 Set ID Full ASCII Code39 Set ID GS1 Databar RSS Limited Set ID GS1 Databar RSS Expanded Set ID GS1 Databar RSS Set ID LABEL Code Set ID Reserved ...

Page 21: ...21 DELAY BETWEEN BLOCKS AND CHARACTERS GROUP 10 INTERBLOCK DELAY INTERCHARACTER DELAY 0mS 10mS 50mS 100mS 200mS 500mS 140uS 500uS 1mS 4mS 16mS ...

Page 22: ...REE A006 GROUP 11 KEYBOARD LAYOUT CAPLOCK MODE NUMERIC KEY KEYBOARD LAYOUT CAPITAL LOCK MODE NUMERIC KEY NOTE 1 When barcode scanner is set to Caplock Free mode no matter keyboard Capslock LED indicator is ON or OFF output will be always the same as the Original barcode In other words what you see is what output is CODABAR is the exception 2 If ABCD ABCD abcd abcd ABCD T E abcd tn e are on they wo...

Page 23: ...5 7 Bits ODD E014 8 Bits SPACE E012 8 Bits EVEN E009 7 Bits EVEN E013 8 Bits None E008 600 E002 1200 E003 2400 E004 9600 E006 4800 E005 300 E001 19200 E007 38400 E022 7 Bits SPACE E021 GROUP 12 RS232 BAUD RATE DATA BITS PARITY BAUD RATE DATA BITS PARITY ...

Page 24: ...3 OFF E024 2 STOP BITS E017 1 STOP BIT E016 RS232 BCC Char On E029 RS232 BCC Char Off E030 RTS enable at Power on E019 RTS enable with Communication E020 GROUP 13 RS232 STOP BIT HANDSHAKING ACK NAK FLOW CONTROL BCC STOP BITS HANDSHAKING ACK NAK FLOW CONTROL TIME OUT BCC ...

Page 25: ...03 200us D001 Bar High Space Low D005 Bar Low Space High D006 PEN TYPE D007 FULL ASCII CODE 39 D008 GROUP 14 WAND EMULATION PARAMETER SETTING LEVEL DURATION OF MINI WIDTH POLARITY OF IDLE CONDITION OUTPUT OF WAND EMULATION WAVE FORM ...

Page 26: ... ENABLE ALL CODE A002 INDUSTRIAL 2 OF 5 N001 MATRIX 2 OF 5 M010 TELEPEN L014 ENABLE DISABLE SYMBOLOGIES CHINA POSTAL CODE K002 CODE 128 J011 CODABAR I 002 INTERLEAVED 2 OF 5 J002 CODE 32 K011 UK PLESSEY CODE L011 DISABLE ALL CODE A003 INDUSTRIAL 2 OF 5 N002 MATRIX 2 OF 5 M011 TELEPEN L015 ENABLE DISABLE GROUP 15 ...

Page 27: ...AN 8 I 011 CODE 11 G011 CODE 93 M002 EAN 128 L002 MSI G009 CODE 39 N018 IATA ENABLE DISABLE SYMBOLOGIES H001 UPC A H007 UPC E H013 EAN 13 H019 EAN 8 I 010 CODE 11 G010 CODE 93 M001 EAN 128 L001 MSI G008 CODE 39 N017 IATA ENABLE DISABLE GROUP 16 ...

Page 28: ... LIMITED DISABLE N011 GS1 Databar EXPANDED DISABLE N027 GS1DatabarEXPANDEDSTACKEDDISABLE N029 PDF417 DISABLE G022 GS1 Databar ENABLE N032 GS1 Databar STACKED ENABLE N038 GS1 Databar LIMITED ENABLE N010 GS1 Databar EXPANDED ENABLE N026 GS1DatabarEXPANDEDSTACKEDENABLE N028 PDF 417 ENABLE G021 ENABLE DISABLE SYMBOLOGIES CHINA POSTAL CODE ENABLE DISABLE GROUP 17 CHINA POSTAL CODE TOSHIBA CODE ...

Page 29: ...gth and or Max Length are enabled the scanner will only read bar codes that fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a st...

Page 30: ...MSI UK PLESSEY CODE ENABLE DISABLE CDV SEND CD CDV NOT SEND CD CHECK DIGIT DOUBLE MOD 10 CHECK DIGIT DOUBLE 11 PLUS MOD 10 CHECK DIGIT SINGLE MOD 10 MIN LENGTH 6 MAX LENGTH 48 ENABLE DISABLE CDV SEND CD L001 L002 L004 L003 L007 L008 L009 L005 L006 L010 L011 L012 L013 ...

Page 31: ...gth and or Max Length are enabled the scanner will only read bar codes that fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a st...

Page 32: ... 19 ENABLE MIN LENGTH 6 MAX LENGTH 48 DISABLE ENABLE DISABLE DISABLE CDV ENABLE TELEPEN TELEPEN ASCII TELEPEN NUMBER DISABLE TELEPEN CDV NOT SEND CDV CDV SEND CD MAX LENGTH 48 MIN LENGTH 6 G010 G011 G012 G013 L014 L015 L020 L021 N017 N018 N019 N020 N021 N022 N023 ...

Page 33: ...gth and or Max Length are enabled the scanner will only read bar codes that fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a st...

Page 34: ... J007 I 010 I 011 I 012 I 013 I 042 I 043 I 014 I 015 I 016 DISABLE CDV SEND CD CDV NOT SEND CD First digit suppressed Last digit suppressed MIN LENGTH 6 MAX LENGTH 48 ENABLE CDV SEND CD CDV SEND CD 1 DIGIT CDV SEND CD 2 DIGITS CDV NOT SEND CD MIN LENGTH 6 MAX LENGTH 32 ENABLE DISABLE CDV NO suppressed DISABLE DISABLE CDV ...

Page 35: ...gth and or Max Length are enabled the scanner will only read bar codes that fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a st...

Page 36: ...STRIAL 2 OF 5 MATRIX 2 OF 5 N001 N002 N003 N004 N007 N006 N005 M010 M011 M012 M013 M016 M015 M014 DISABLE DISABLE CDV DISABLE DISABLE CDV ENABLE CDV SEND CD CDV NOT SEND CD MIN LENGTH 6 MAX LENGTH 48 ENABLE CDV SEND CD MAX LENGTH 48 MIN LENGTH 6 CDV NOT SEND CD ...

Page 37: ...gth and or Max Length are enabled the scanner will only read bar codes that fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a st...

Page 38: ...ABCD ABCD SEND START STOP CLSI FORMAT Example of ST Start SP Stop 123456 Not Transmit ST SP A123456B ST SP ABCD ABCD a123456b ST SP abcd abcd A123456N ST SP ABCD TN E a123456n ST SP abcd tn e CLSI Enable library space insertion If you enable the CLSI format this option inserts spaces in position 2 7 13 of the data string for use in library systems I 001 I 002 I 005 I 006 I 007 I 008 I 009 I 030 I ...

Page 39: ...gth and or Max Length are enabled the scanner will only read bar codes that fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a st...

Page 40: ...mission The ABC Code is an acronym for American Blood Commission This bar code is a variant of the CODABAR Code developed for the use in the blood bank This Code consists of two bar codes which are decoded in one read cycle The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D these two D are not transmitted The CX Code consist...

Page 41: ...ll be sent The data can be any alphanumerics of FULL ASCII Table GROUP 33 44 page 51 62 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again If CODABAR ADJACENT is enabled the scanner will only read two adjacent Codabar bar codes a single bar code will not be read Step 1 Scan SET INSERT DATA Step 2 ...

Page 42: ...TART STOP Not SEND G001 FULL ASCII CODE 39 ENABLE K015 TAILING NOT SEND K014 TAILING SEND K013 LEADING NOT SEND K010 ENABLE K011 DISABLE K012 LEADING SEND GROUP 25 SYMBOLOGIES STANDARD FULL ASCII CODE 39 CODE 32 STANDARD CODE 39 FULL ASCII 39 CODE 32 NOTE The default for Code 39 is Standard Code 39 If Full ASCII Code 39 is enabled Standard Code 39 will be automatically disabled ...

Page 43: ...gth and or Max Length are enabled the scanner will only read bar codes that fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a st...

Page 44: ...F H047 ADD A SPACE ON H048 ADD A SPACE OFF H055 ADDENDA REQUIRED OFF H056 ADDENDA REQUIRED ON GROUP 26 SYMBOLOGIES FORMATTING UPC E UPC E ADD ON SUPPLEMENT If ADDENDA REQUIRED is set to ON the scanner will only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON so the scanner will output a 5 digit or 2 digit addendum NOTE ...

Page 45: ...Most UPC bar codes lead with 0 number systems for these bar codes use UPC E 0 selection For the bar codes that lead with the 1 number use UPC E 1 selection 1 If UPC E EXPAND TO UPC A FORMAT is enabled the output of UPC A will be 12 digits 2 The default output of UPC A is 12 digits if UPC A EXPAND TO EAN13 is enabled a zero will be added to in front of the bar code ...

Page 46: ...46 ADD A SPACE OFF H067 DISABLE H068 ENABLE ADDENDA REQUIRED ON H060 ADDENDA REQUIRED OFF H059 GROUP 28 SYMBOLOGIES FORMATTING UPC A UPC A UPC A EXPAND TO EAN 13 ADD ON SUPPLEMENT If ADDENDA REQUIRED is set to ON the scanner will only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON so the scanner will output a 5 digit or 2 digit addendum NOTE ...

Page 47: ...E ON H043 H044 ADD A SPACE OFF ENABLE H019 ADDENDA REQUIRED ON H062 ADDENDA REQUIRED OFF H061 If ADDENDA REQUIRED is set to ON the scanner will only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON so the scanner will output a 5 digit or 2 digit addendum NOTE GROUP 29 SYMBOLOGIES FORMATTING EAN 8 EAN 8 ADD ON SUPPLEMENT ...

Page 48: ...ADD ON SUPPLEMENT ISBN ISSN ISMN Both ISSN and ISBN are the extension codes of EAN 13 If scanner is required to read either ISSN or ISBN EAN 13 must be enabled Otherwise the scanner will not be able to read ISSN or ISBN NOTE NOTES 1 If ADDENDA REQUIRED is set to ON the scanner will only read an EAN 13 bar code that has an addenda 2 Either ISSN or ISBN will be considered as an extension of EAN 13 I...

Page 49: ... 5 J013 MAX LENGTH 48 GROUP 31 SYMBOLOGIES EAN UCC 128 CODE 128 EAN UCC 128 CODE 128 PDF417 NOTES DEFINE EAN 128 String format Setting Procedure The first FNC1 character is translated to c1 and the second FNC1 character is translated to an ASCII GS character scan from Group 41 page 59 1 Scan DEFINE EAN128 2 Scan ASCII Code page 59 3 Scan DEFINE EAN128 DISABLE G022 ENABLE G021 ...

Page 50: ...END N039 GS1 DataBar STACKED DISABLE N010 GS1 DataBar LIMITED ENABLE N012 GS1DataBarLIMITEDCHECKDIGITSEND N024 GS1 DataBar LIMITED PREFIX SEND P019 GS1 DataBar LIMITED SET ID N011 GS1 DataBar LIMITED DISABLE N013 GS1DataBarLIMITEDCHECKDIGITNOTSEND N025 GS1 DataBar LIMITED PREFIX NOT SEND N026 GS1 DataBar EXPANDED ENABLE N028 GS1DataBarEXPANDEDSTACKEDENABLE N030 GS1 DataBar EXPANDED MIN LENGTH P020...

Page 51: ...51 F H J D L B U N I K M G E C A O GROUP 33 FULL ASCII TABLE CODE 39 CONTROL CODES NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI ...

Page 52: ...52 T V X Z P R D B Q W Y A S U C E GROUP 34 FULL ASCII TABLE CODE 39 CONTROL CODES DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SP ...

Page 53: ...53 F H A C V J Q S L N 0 GROUP 35 FULL ASCII TABLE CODE 39 SYMBOLS ...

Page 54: ...54 B F J G Z I G I H L P R T W K M GROUP 36 DEL FULL ASCII TABLE CODE 39 SYMBOLS ...

Page 55: ...55 I K L G M H J A C E B F D A B C D E F G H I J K L M GROUP 37 FULL ASCII TABLE CODE 39 UPPER CASE ALPHABETS ...

Page 56: ...56 X Z V Y W N T P R O S Q U GROUP 38 N O P Q R S T U V W X Y Z FULL ASCII TABLE CODE 39 UPPER CASE ALPHABETS ...

Page 57: ...57 F H J L G I K M E B A C D GROUP 39 a b c d e f g h i j k l m FULL ASCII TABLE CODE 39 LOWER CASE ALPHABETS ...

Page 58: ...58 U W Y V X Z T N P R O Q S FULL ASCII TABLE CODE 39 LOWER CASE ALPHABETS GROUP 40 n o p q r s t u v w x y z ...

Page 59: ...59 FULL ASCII TABLE CODE 39 NUMBERS GROUP 41 0 1 2 3 4 5 6 7 8 9 ...

Page 60: ...60 FULL ASCII TABLE CODE 39 FUNCTION KEYS GROUP 42 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Home End Enter Numeric Key App TA TB TC TD TE TF TG TH TI TJ TK TL TM TN T D T O ...

Page 61: ...61 TU TW TS TQ TY TO TZ TV TT TR TX TP T K FULL ASCII TABLE CODE 39 NAVIGATION KEYS GROUP 43 Cursor Right Cursor Left Cursor Up Cursor Down Page Up Page Down Tab Back Tab Esc Enter BS Ins Del ...

Page 62: ... Right make T E Alt Right make T M Win Right make T K Win Left make T I Shift Right make FULL ASCII TABLE CODE 39 MODIFIER KEYS GROUP 44 For UK Keyboard Special Character Note 1 When Alt Left Make is programmed please scan Alt Left Break to resume barcode setting 2 When Shift Left Make is programmed please scan Shift Left Break to resume barcode setting 3 When Ctrl Left Make is programmed please s...

Page 63: ... the scanner indicates a good read but there is no output of data to the monitor please check the cabling connection In general the Keyboard Wedge interface is trouble free but there is still something to check in the event of a problem Do you have the correct cable Most computers use an XT AT compatible keyboard Be sure you have the proper cable for your computer Does the keyboard work Since the ...

Page 64: ...the bar code symbology you are trying to read Although the cable seems to connect properly does the scanner not send data to the host computer There are no industrial standards for scanner interface cables so even if they look alike and have similar connector they might not be alike For example cables for Keyboard Wedge and Wand Emulation are similar but they are not interchangeable due to diơeren...

Page 65: ...uld be chosen to generate bar codes If the printed bar codes are distorted the scanner might not recognize them It is very diƥcult to get a good read from a poor quality bar code unless it is scanned many times As the quality of the symbology drops the chances for undetected error increase A bar code Check Digit VeriƤcation CDV should be used to check the quality of the suspect bar codes LABELS PA...

Page 66: ...h Polarity of Idle Condition Output of Wand Emulation Bar High Space Low Full ASCII 39 Wave Form Enable and Disable Symbologies Code 32 China Postal Code UK Plessey Code Industrial 2 of 5 Matrix 2 of 5 Interleaved 2 of 5 Code 128 Codabar Telepen UPC A UPC E EAN 8 EAN 13 MSI Code 39 Code 11 PC AT Disable Enable Disable Disable Disable Enable Enable Enable Disable Enable Enable Enable Enable Disable...

Page 67: ...digits Disable Disable CDV 1 digit 48 digits No suppressed Start Stop Full ASCII 39 Enable Disable Not Send Disable CDV Enable 2 Enable Disable Check Digits Min Length Max Length Disable Disable CDV 6 digits 48 digits 3 6 digits 48 digits Enable Disable Min Length Max Length Disable Enable Disable Telepen ASCII Number Disable Number 1 2 19 1 2 20 1 2 21 Enable Disable Check Digits Min Length Max L...

Page 68: ...Off Off Enable Send Send Off Off Off Off Enable Disable Check Digits Enable Disable Check Digits Lead Digits Add a space Addenda required 5 On Off 2 On Off Enable Send Send Off Off Off Off Off Off ISSN On Off ISBN Enable Disable Code ID Func 1 Char Send Enable Disable Not Send Min Length Max Length Enable Enable Disable Disable Disable CDV 5 digits 48 digits Disable Not Send Not Send Enable Disabl...

Page 69: ...eyboard Interface 1 2 Din 5 male 240 degree Pin Signal 2 7 9 Data GND 5VCC Pin Signal 1 2 3 4 5 5VCC Data GND N A N A 2 1 PS 2 Mini Din6 Female Type of connector Pin 1 2 3 4 5 6 1 2 3 4 5 6 Signal Pin Signal PC Data NC GND 5VCC PC Clk NC 2 2 PS 2 Mini Din6 Male KB Data NC NC GND 5VCC KB Clk ...

Page 70: ...Pin Signal 1 2 3 4 5 KB Clk KB Data NC GND 5VCC Pin 1 2 3 4 5 Signal PC Clk PC Data NC GND 5VCC 3 RS232 Interfaces 3 1 DB9F 3 2 DB25F Pin Signal Pin Signal 2 3 5 7 8 9 TXD Out RXD In GND CTS In RTS Out 5VCC 2 3 4 5 7 16 25 RXD In TXD Out CTS In RTS Out GND 5VCC 5VCC ...

Page 71: ...71 APPENDIX 3 BAR CODE TEST CHART DENSITY MEDIUM DENSITY NARROW mm mil WIDE mm mil CHAR GAP mm mil N W RATIO MEDIUM DENSITY NW 7 CODABAR CODE 39 Interleaved 2of5 UPC EAN 0 25 10 0 625 25 0 25 10 1 2 5 ...

Page 72: ...72 APPENDIX 3 BAR CODE TEST CHART DENSITY LOW DENSITY NARROW mm mil WIDE mm mil CHAR GAP mm mil N W RATIO 0 33 13 0 825 32 5 0 33 13 1 2 5 LOW DENSITY ...

Page 73: ...73 http www idtechproducts com 80126502 001 rev A ...

Reviews: