background image

 

 

AUPS Series Power Module User Manual 

Page i 

User Manual 

 

Model: 

AUPS Series 

VESA Mount Intelligent UPS Module 
12 V DC Input or 9 V

36 V DC Input 

Network Remote Management Support 

Rev. 2.00 – July 3, 2018 

Summary of Contents for AUPS Series

Page 1: ...AUPS Series Power Module User Manual Page i User Manual Model AUPS Series VESA Mount Intelligent UPS Module 12 V DC Input or 9 V 36 V DC Input Network Remote Management Support Rev 2 00 July 3 2018 ...

Page 2: ... Manual Page ii Revision Date Version Changes July 3 2018 2 00 Updated for R20 version Battery Specifications Chapter 4 Software Application May 7 2014 1 01 Added Appendix A Safety Precautions November 12 2008 1 00 Initial release ...

Page 3: ...l damages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of the manufacturer TRADEMARKS All register...

Page 4: ...ly CAUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product NOTE These messages inform the reader of essential but non critical information These messages should be read carefully as any directions or instructions contained therein can help avoid making mistakes HOT SURFACE This symbol indicates a hot surface that should not be touched without t...

Page 5: ...dicators 6 1 4 AUPS SERIES SPECIFICATIONS 7 1 5 BATTERY SPECIFICATIONS 8 1 5 1 AUPS A10 AUPS A20 Battery 8 1 5 2 AUPS B10 AUPS B20 Battery 10 1 6 AUPS SERIES DIMENSIONS 12 1 6 1 AUPS A10 AUPS A20 Dimensions 12 1 6 2 AUPS B10 AUPS B20 Dimensions 13 2 UNPACKING 14 2 1 ANTI STATIC PRECAUTIONS 15 2 2 UNPACKING 15 2 2 1 Unpacking Precautions 15 2 3 UNPACKING CHECKLIST 16 2 3 1 Package Contents 16 3 INS...

Page 6: ...PPLICATION INSTALLATION 29 4 4 MONITORING DC POWER AND SMART BATTERY 31 4 4 1 Status Information 31 4 4 1 1 DC Power Status 31 4 4 1 2 Battery Status 32 4 4 2 Battery Information 33 4 4 3 LAN Setting 34 4 4 3 1 Using Static IP 35 4 4 4 Setting 36 4 4 5 E mail 37 4 5 REMOTE CONTROL AND MONITORING 38 A SAFETY PRECAUTIONS 43 B HAZARDOUS MATERIALS DISCLOSURE 49 ...

Page 7: ... 21 Figure 3 3 Battery Pack Installation 21 Figure 3 4 Mounting Bracket Installation 22 Figure 3 5 Mounting the AUPS Series 22 Figure 3 6 AUPS Series and Panel PC Connection 23 Figure 4 1 Preparing Setup Screen 25 Figure 4 2 Driver Welcome Screen 26 Figure 4 3 Driver License Agreement Screen 26 Figure 4 4 Choose Destination Location 27 Figure 4 5 Ready to Install the Driver 27 Figure 4 6 InstallSh...

Page 8: ... mail Setting 37 Figure 4 19 RJ 45 Remote LAN Connector 38 Figure 4 20 Remote AP 39 Figure 4 21 Remote AP IP Address 39 Figure 4 22 Remote Management Web Interface Status 40 Figure 4 23 Remote Management Web Interface Send Email 40 Figure 4 24 Enter User Name and Password 41 Figure 4 25 Remote Management Web Interface Configuration 42 ...

Page 9: ...ual Page ix List of Tables Table 1 1 LED Indicators 6 Table 1 2 AUPS Series Specifications 7 Table 1 3 AUPS A10 AUPS A20 Battery Specifications 9 Table 1 4 AUPS B10 AUPS B20 Battery Specifications 11 Table 2 1 Package List Contents 17 ...

Page 10: ......

Page 11: ...AUPS Series Power Module User Manual Page 1 Chapter 1 1 Introduction ...

Page 12: ...tain of time in power failure The AUPS Series UPS module comes with the utility software that provides information on current power source and battery status With the AUPS software installed and network connected the AUPS Series can be monitored and turned on off through a remote computer 1 2 AUPS Series UPS Module Features Rugged metal enclosure for standard VESA 75 100 mounting Wide range power ...

Page 13: ...see Figure 1 2 has the following standard I O interface connectors 1 x 12 V DC output jack 1 x USB mini B connector 1 x Network remote management port RJ 45 1 x DC output switch terminal block 1 x DC on off button The standard external I O interface connector panel is shown in Figure 1 2 Figure 1 2 AUPS Series Standard I O Interface Connectors ...

Page 14: ...ctor The AUPS A10 has one power jack for 12 V DC input Figure 1 3 Figure 1 3 AUPS A10 Power Input Connector 1 3 1 2 AUPS A20 Power Input Connectors The AUPS A20 has one power jack and one terminal block for 9 V 36 V DC inputs Figure 1 4 Figure 1 4 AUPS A20 Power Input Connectors ...

Page 15: ...PS B10 has one 4 pin power connector for 12 V DC input Figure 1 5 Figure 1 5 AUPS B10 Power Input Connector 1 3 1 4 AUPS B20 Power Input Connectors The AUPS B20 has one 4 pin power connector and one terminal block for 9 V 36 V DC inputs Figure 1 6 Figure 1 6 AUPS B20 Power Input Connectors ...

Page 16: ...e the power and battery status Figure 1 7 Figure 1 7 AUPS Series LED Indicators All the LED statuses are listed in Table 1 1 Power Input LED Charger Status LED Battery Status LED Color Green Yellow Orange Off DC power out On DC power in Discharging battery full Battery discharging Blinking Charging Battery low Table 1 1 LED Indicators ...

Page 17: ...n 4S2P Li ion 4S2P Nominal Voltage 7 26 V 7 26 V 14 52 V 14 52 V Nominal Capacity 5200 mAh 5200 mAh 5200 mAh 5200 mAh Physical Dimensions LxWxH 150 x 95 x 34 mm 150 x 95 x 34 mm 170 x 150 x 34 mm 170 x 150 x 34 mm Weight 1 2 kg 1 2 kg 1 8 kg 1 8 kg LED Green DC power input DC power input DC power input DC power input Yellow Battery charging Battery charging Battery charging Battery charging Orange...

Page 18: ...ge at 25 3 C cut off voltage at 2 75 V cell Nominal Voltage 7 26 V 0 5C charge 0 2C discharge at 25 3 C cut off voltage at 2 75 V cell End of Discharge Voltage 5 5 V FD set 5 5 V Charge Voltage 0 10 C 11 45 C 46 60 C Charging Voltage 8400 mV 8400 mV 8200 mV Rated Charge Current 0 10 C 11 45 C 46 60 C Per cell 2 75V 510 mA 510 mA 510 mA 2 75V Per cell 4 1V 1530 mA 2550 mA 2550 mA 4 1V Per cell 4 2V...

Page 19: ... Protection Cell 2 35V delay time 30 sec Over Discharge Current Protection SW Set 10 04A delay time 5 7 sec Reset Current 20mA then 30 sec Over Discharge Current Protection AFE Set 11 5 14 5A typical 12 95A delay time 31 4 mSec Reset after 30 sec and then current 5mA Short circuit Protection Set 30 20 A delay time 700uSec 1200uSec typical 916uSec Reset after 30sec and then current 5mA Over Charge ...

Page 20: ... 75 V cell End of Discharge Voltage 11 V FD set 11 V Charge Voltage 0 10 C 11 45 C 46 60 C Charging Voltage 16800 mV 16800 mV 16400 mV Rated Charge Current 0 10 C 11 45 C 46 60 C Per cell 2 75V 510 mA 510 mA 510 mA 2 75V Per cell 4 1V 1530 mA 2550 mA 2550 mA 4 1V Per cell 4 2V 1530 mA 2550 mA 0 mA Pre charge Current 510 mA cell 2 75 V Gas gauge reports charge current as 510 mA Max Continuous Disch...

Page 21: ...ischarge Current Protection SW Set 10 04A delay time 5 7 sec Reset Current 20mA then 30 sec Over Discharge Current Protection AFE Set 11 5 14 5A typical 12 95A delay time 31 4 mSec Reset after 30 sec and then current 5mA Short circuit Protection Set 30 20 A delay time 700uSec 1200uSec typical 916uSec Reset after 30sec and then current 5mA Over Charge Current Protection Set 5 2A delay time 2 4 sec ...

Page 22: ...PS Series Power Module User Manual Page 12 1 6 AUPS Series Dimensions 1 6 1 AUPS A10 AUPS A20 Dimensions The AUPS A10 and AUPS A20 dimensions are shown in Figure 1 8 Figure 1 8 AUPS A10 A20 Dimensions mm ...

Page 23: ...AUPS Series Power Module User Manual Page 13 1 6 2 AUPS B10 AUPS B20 Dimensions The AUPS B10 and AUPS B20 dimensions are shown in Figure 1 8 Figure 1 9 AUPS B10 B20 Dimensions mm ...

Page 24: ...AUPS Series Power Module User Manual Page 14 Chapter 2 2 Unpacking ...

Page 25: ...i static wristband can help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any conducting materials that are connected to the ground Use an anti static pad When configuring the AUPS Series place it on an antic static pad This reduces the possibility of ESD damaging the AUPS...

Page 26: ...IEI reseller or vendor you purchased the AUPS Series from or contact an IEI sales representative directly To contact an IEI sales representative please send an email to sales ieiworld com tw 2 3 1 Package Contents The AUPS Series is shipped with the following components Quantity Item Image 1 AUPS Series UPS module 1 Li ion battery pack 1 Mounting bracket 1 DC output cable 1 DC output switch cable ...

Page 27: ...AUPS Series Power Module User Manual Page 17 1 USB Type A to mini B cable 1 Screw kit 2 Wall mount bracket Table 2 1 Package List Contents ...

Page 28: ...AUPS Series Power Module User Manual Page 18 Chapter 3 3 Installation ...

Page 29: ... can help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any conducting materials that are connected to the ground Use an anti static pad When configuring the AUPS Series place it on an antic static pad This reduces the possibility of ESD damaging the AUPS Series Only handl...

Page 30: ...steps must be followed Step 1 Unpack the UPS module Step 2 Install the battery pack Step 3 Mount UPS module to the AFOLUX panel PC Step 4 Connect the UPS module to the AFOLUX panel PC Step 0 3 4 Battery Pack Installation The battery pack must be installed to enable the UPS module To install the battery pack follow the steps below Step 1 Remove the four top cover retention screws Figure 3 1 and Fig...

Page 31: ... Figure 3 3 Figure 3 3 Battery Pack Installation Step 3 Secure the battery pack with two retention screws Step 4 Replace the top cover Step 0 3 5 Mounting the AUPS Series To mount the AUPS Series onto the rear panel of the AFOLUX panel PC follow the steps below Step 1 Install the mounting bracket onto the rear panel of the AFL panel PC Align the screw holes in the mounting bracket with the VESA sc...

Page 32: ...l PC with four retention screws Figure 3 4 Figure 3 4 Mounting Bracket Installation Step 2 Place the AUPS Series onto the mounting bracket Secure the AUPS Series to the bracket with three retention screws one on the top panel and one on each side panel Figure 3 5 Figure 3 5 Mounting the AUPS Series ...

Page 33: ... Page 23 3 6 Connecting the AUPS Series To support the UPS function to the panel PC the AUPS Series must be connected to the power source and to the panel PC Figure 3 6 shows the connections Figure 3 6 AUPS Series and Panel PC Connection ...

Page 34: ...AUPS Series Power Module User Manual Page 24 Chapter 4 4 Software Application ...

Page 35: ...ery status It is recommended to execute this AUPS application in Windows 7 or above 4 2 Driver Installation Follow the steps below to install the necessary drivers Step 1 Download AUPS driver from IEI website Step 2 Run the CP210x_VCP_Win2K_XP_S2K3 exe file The InstallShield Wizard prepares the setup as shown Figure 4 1 Figure 4 1 Preparing Setup Screen ...

Page 36: ...ure 4 2 To continue the installation process click Next Figure 4 2 Driver Welcome Screen Step 4 The license agreement in Figure 4 3 appears Read the License Agreement Check I accept the terms of license agreement and click Next to continue Figure 4 3 Driver License Agreement Screen ...

Page 37: ...ion window appears Figure 4 4 Select a folder to install the driver Figure 4 4 Choose Destination Location Step 6 Click Next and the InstallShield Wizard is ready to install the driver Figure 4 5 Step 7 Click Install to start the installation Figure 4 5 Ready to Install the Driver ...

Page 38: ...to launch the CP210x USB to UART Bridge Driver Installer Figure 4 6 InstallShield Wizard Complete Screen Step 9 Click Install to start installing the CP210x USB to UART Bridge driver Figure 4 7 Figure 4 7 CP210x USB to UART Bridge Driver Installer Step 10 When the installation is complete the screen in Figure 4 8 appears Click Finish to exit Figure 4 8 Installation Complete ...

Page 39: ...1 Download the AUPS setup file from IEI website Run the AUPS_SetupV100A exe file Step 2 A welcome screen appears Figure 4 9 To continue the installation process click Install Figure 4 9 Welcome Screen Step 3 The Setup Wizard starts installing the program Step 4 The Installation Complete window appears Figure 4 10 Click Finish to exit ...

Page 40: ...PS Series Power Module User Manual Page 30 Figure 4 10 Installation Complete Step 5 To launch the application double click the shortcut Figure 4 11 on the desktop Figure 4 11 IEI AUPS Application Overview ...

Page 41: ...lication shows the DC power status and battery status Figure 4 12 The following sections describe the status information in details Figure 4 12 Status Information 4 4 1 1 DC Power Status When the DC power is connected to the AUPS series power module the AUPS application detects it and shows in the screen as Figure 4 13 Figure 4 13 DC Detection ...

Page 42: ...rt battery installed in the AUPS series power module and shows the battery status in the screen Capacity Current battery capacity Using The battery is being used Charging The battery is being charged Standby The battery is fully charged and ready to be used anytime Temperature Current battery temperature ...

Page 43: ...is shown in the top of the battery screen to indicate the total battery remaining time this information will not be displayed when the battery is being charged Other information includes battery type capacity output voltage temperature charging rate and discharging rate Figure 4 14 The values listed are updated per second Figure 4 14 Battery Information ...

Page 44: ...User Manual Page 34 4 4 3 LAN Setting The LAN page is where to configure the Remote LAN settings for power on off remote control and battery monitoring To save the modified Host Name click the SET button Figure 4 15 LAN Setting ...

Page 45: ...P DHCP is enabled by default in the application To use static IP disable the DHCP option and fill in the network information To save the modified parameters of this page click the SET button To load the default settings click button Figure 4 16 LAN Setting Disable DHCP ...

Page 46: ...e battery power Enable LAN Enable or disable the LAN for remote monitoring function Power Click the button to power off the AUPS power module immediately Auto DC on Enable to automatically power on the AUPS once DC power is applied Shut down condition capacity Set the battery capacity parameter for the system to shut down automatically DC off delay time 0 65536 sec Set the delay time for the AUPS ...

Page 47: ...ameter for the system to go into sleep mode automatically 4 4 5 E mail The E MAIL page is where to set the SMTP settings for sending alert notification via e mail This page contains three alert options for you to choose They are DC adapter power off System go to sleep mode DC adapter power restored NOTE To save the SMTP settings fully exit the AUPS application by right clicking or long pressing th...

Page 48: ...ure 4 19 RJ 45 Remote LAN Connector Step 2 In a remote computer install the IEI AUPS application by following the instruction described in Section 4 2 After installation launch the AP Step 3 On the IEI AUPS application screen click the Remote AP tab Figure 4 20 All the AUPS Series modules in the same subnet with this remote computer are shown in the list on the right Check to select one or multipl...

Page 49: ...wer Module User Manual Page 39 Figure 4 20 Remote AP Step 4 To access the web interface for advanced monitoring and functions double click the IP address of the connected AUPS Series Figure 4 21 Remote AP IP Address ...

Page 50: ... 22 Remote Management Web Interface Status Step 6 To send an email to an administrator through the SMTP server click Send E mail button on the left Fill out the information as indicated in Figure 4 23 Click the Send Message button to send the email Figure 4 23 Remote Management Web Interface Send Email ...

Page 51: ...prompts for the user name and password The default user name and password for the LAN setting page are User name admin Password IEI Figure 4 24 Enter User Name and Password Step 9 The Board Configuration window appears Configure the network settings and click the Save Config button Incorrect settings may cause the board to lose network connectivity Step 0 ...

Page 52: ...AUPS Series Power Module User Manual Page 42 Figure 4 25 Remote Management Web Interface Configuration ...

Page 53: ...AUPS Series Power Module User Manual Page 43 Appendix A A Safety Precautions ...

Page 54: ...more than 80 In case that separator made of polymer is melted by high temperature the internal short circuit occurs in individual cells and then it causes the generating heat smoke rupture or flame In addition do not use the battery under the heated place more than 80 for same reason 5 Immersion Do not immerse the battery in water or sea water or get it wet If the protection circuit included in th...

Page 55: ...ake the direct soldering on battery As the insulator is melted by heat or the gas release vent or safety function is broken it caused the generating heat smoke rupture or flame 12 Reverse Charge and Overdischarge Do not reverse polarity and terminals On charging the battery is reverse charged and abnormal chemical reaction occurs And also there may be case that unexpected large current flows on di...

Page 56: ...n use And it may cause the generating smoke rupture or flaming because of the abnormal chemical reaction in cells 2 Ingestion Keep the battery away from babies Keep the little battery out of the reach of babies in order to avoid troubles by swallowing In case of swallowing the battery see a doctor immediately 3 Charging Time Do not continue to charge battery over specified time If the battery is n...

Page 57: ...mage to the protection circuit If protection circuit were broken the battery would generate smoke rupture or flame 3 Charging Temperature Range Charging temperature rage is regulated 0 and 40 Do not charge the battery out of recommended temperature range Charging out of recommended range might cause the generating heat or serious damage of battery And also it might cause the deterioration of batte...

Page 58: ...eep the battery out of the reach of younger children And also pay attention when the battery is taken out from the charger or equipment by little children 9 Leakage If the skin or cloth is smeared with liquid from the battery wash with fresh water It may cause the skin inflammation ...

Page 59: ...AUPS Series Power Module User Manual Page 49 Appendix B B Hazardous Materials Disclosure ...

Page 60: ... and lamps These components will be separately marked Please refer to the following table Part Name Toxic or Hazardous Substances and Elements Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium CR VI Polybrominated Biphenyls PBB Polybrominated Diphenyl Ethers PBDE Housing O O O O O O Display O O O O O O Printed Circuit Board O O O O O O Metal Fasteners O O O O O O Cable Assembly O O O O O O Fan Ass...

Page 61: ...换元件 像是电池或灯管 这些元 件将会单独标示出来 部件名称 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 CR VI 多溴联苯 PBB 多溴二苯 醚 PBDE 壳体 O O O O O O 显示 O O O O O O 印刷电路板 O O O O O O 金属螺帽 O O O O O O 电缆组装 O O O O O O 风扇组装 O O O O O O 电力供应组装 O O O O O O 电池 O O O O O O O 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ T 11363 2006 现由 GB T 26572 2011 取代 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T 11363 2006 现由 GB T 26572 2011 取代 标准规定的限量要求 ...

Reviews: