background image

 

 

MODAT-100 

Page 1 

IEI Technology Corp. 

User Manual 

 

MODEL: 

MODAT-100 

Industrial PDA with Barcode Scanner for Ticketing,   

 

Membership Verification, Real-time Transactions 

 

Rev. 1.04 – 12 March, 2012 

Summary of Contents for MODAT-100

Page 1: ...MODAT 100 Page 1 IEI Technology Corp User Manual MODEL MODAT 100 Industrial PDA with Barcode Scanner for Ticketing Membership Verification Real time Transactions Rev 1 04 12 March 2012 ...

Page 2: ...rocedure 9 September 2011 1 03 Updated Section 1 5 Specifications 8 August 2011 1 02 Added printing notice to Pg 4 Update to Section 2 3 Charging the System Added Section 2 6 Synchronized with Windows 7 System Added text size adjustment information 1 April 2011 1 01 Minor update to Section 1 4 1 Front Panel 17 March 2011 1 00 Initial release ...

Page 3: ...ng out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of the manufacturer TRADEMARKS All registered trademarks a...

Page 4: ...quipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from ...

Page 5: ...1 6 DIMENSIONS 12 2 INSTALLATION 13 2 1 UNPACKING THE DEVICE 14 2 2 PACKING LIST 15 2 2 1 Optional Items 15 2 3 CHARGING THE SYSTEM 16 2 3 1 Using the Optional Cradle 17 2 4 INSTALLING A SIM SAM CARD 18 2 5 POWER ON OFF PROCEDURE 20 2 6 SYNCHRONIZED WITH WINDOWS 7 SYSTEM 20 A SAFETY PRECAUTIONS 22 A 1 SAFETY PRECAUTIONS 23 A 1 1 General Safety Precautions 23 A 1 2 Anti static Precautions 24 A 1 3 ...

Page 6: ...2 Cleaning Tools 26 B INTERNATIONAL STANDARDS COMPLIANCE 27 B 1 EN 60601 1 EN 60601 2 28 B 2 FCC 28 C HAZARDOUS MATERIALS DISCLOSURE 29 C 1 HAZARDOUS MATERIALS DISCLOSURE TABLE FOR IPB PRODUCTS CERTIFIED AS ROHS COMPLIANT UNDER 2002 95 EC WITHOUT MERCURY 30 ...

Page 7: ...ODAT 100 Bottom Panel 8 Figure 1 7 MODAT 100 Rear Panel 9 Figure 1 8 MODAT 100 Dimensions units in mm 12 Figure 2 1 MODAT 100 DC IN Adapter Port 16 Figure 2 2 Battery LED 17 Figure 2 3 Connect the MODAT 100 to the Charging Cradle 17 Figure2 4 Removing the Battery Cover 18 Figure2 5 Removing the Battery 19 Figure2 6 Inserting the SIM SAM Card 19 Figure 2 7 Power Button 20 Figure 2 8 USB to PC Windo...

Page 8: ...MODAT 100 Page 8 List of Tables Table 1 1 MODAT 100 System Specifications 11 Table 2 1 Packing List 15 Table 2 2 Optional Items List 16 ...

Page 9: ...MODAT 100 Page 1 Chapter 1 1 Introduction ...

Page 10: ... thermal printers to be paired with the MODAT 100 increasing the productivity of your staff while on the go A built in vibrator alerts staff immediately allowing them to provide prompt service to customers 1 2 Feature The MODAT 100 features the following 624 MHz Marvell PXA 310 CPU 3 5 sunlight readable high brightness transflective TFT touchscreen with stylus input MicroSD Slot Supports Micro SDH...

Page 11: ...ace com 1 3 Applications The MODAT 100 can be applied in the following places Retail Sales Automation Field Services Hospitality 1 4 External Overview The MODAT 100 combines its features in a stylish enclosure The MODAT 100 consists of a screen rear panel top panel bottom panel and two side panels left and right The panels are described in detail in the following sections ...

Page 12: ...ont Panel 1 x 2 Thermal Printer 1 x Magnetic Stripe Reader 1 x Smart Card Reader 1 x 3 5G WiFi 1 x Battery LED 1 x Keypad The two LEDs on the front panel indicate battery 3 5G and barcode status as described below Battery LED Left 3 5G Barcode LED Right Charging Red Fully Charged Green 3 5G Connection Green ...

Page 13: ...MODAT 100 Page 5 NOTE The user can adjust the text size showed on the screen by going to Start Settings System Screen ...

Page 14: ...MODAT 100 Page 6 1 4 1 1 Keypad The keypad and its functions are shown below Figure 1 3 MODAT 100 Keypad Press the Alpha key to use the orange characters Press the Fn key to use the blue characters ...

Page 15: ...MODAT 100 Page 7 1 4 2 Left Panel The left panel of the MODAT 100 is shown below Figure 1 4 MODAT 100 Left Panel 1 x Barcode Scanner Trigger 1 x MicroSD card slot 1 x Reset button ...

Page 16: ... shown in Figure 1 5 Figure 1 5 MODAT 100 Right Panel 1 x Barcode Scanner Trigger 1 x Stylus 1 4 4 Bottom Panel The bottom panel of the MODAT 100 is shown below Figure 1 6 MODAT 100 Bottom Panel 1 x 16 pin cradle charging connector 1 x Headset port 1 x DC IN Adapter port ...

Page 17: ...0 Rear Panel 1 x LED FlashLight 1 x 1D Laser Barcode Scanner 1 x 3 Megapixel Camera 1 x Speaker 1 x 7 4V 1880mAh Battery 1 5 Specifications The technical specifications for the MODAT 100 systems are listed in Table 1 1 Specification MODAT 100 Microprocessor Marvell PXA 310 624MHz OS Windows Mobile 6 5 ...

Page 18: ... 2100MHz HSDPA GPS with internal antenna Storage One MicroSD slot supports Micro SDHC up to 8GB Audio 1 x Speaker 1 x Microphone 1 x Audio jack for headset Input Methods Touch panel by stylus 25 Key keypad Start Calendar OK Message Numeric Alpha Power F1 F2 Buttons Keys 2 x Barcode hotkeys Default BarcodeL BarcodeR Optional Quick Print Quick Shot Indicators 1 x Battery charging status LED 1 x HSDP...

Page 19: ...ge 36 W Temperature Operating 0 C 50 C Storage 20 C 70 C Humidity 5 95 non condensing Electrostatic Discharge 8k Vdc air discharge 6k Vdc contact discharge Impact Resistance 1 2 m drop survival excluding SCR MSR Printer Dimensions LxWxD 230 mm x 84 mm x 54 mm Net Weight 546 g Barcode Scanner 1D Laser Scan Engine Certifications CE FCC Table 1 1 MODAT 100 System Specifications ...

Page 20: ...MODAT 100 Page 12 1 6 Dimensions Figure 1 8 MODAT 100 Dimensions units in mm ...

Page 21: ...MODAT 100 Page 13 Chapter 2 2 Installation ...

Page 22: ... Unpacking the Device WARNING Only remove the protective plastic cover stuck to the front screen after installation The plastic layer protects the screen surface during the installation process To unpack the MODAT 100 follow these steps Step 1 Cut the sealing tape Only cut deep enough to cut the tape Step 2 Open the box Step 3 Lift out the device Step 4 Remove all the peripheral parts from the box...

Page 23: ...e 1 MODAT 100 1 Battery Pack P N 31603 000014 RS 1 Carrying Case P N 7Z000 MODAT100POUCH RS 1 Power Adapter P N 63000 FSP036RAB613 RS 1 Stylus P N 7Z000 MODAT100STYLUS RS 1 Headset P N Z000 EMI164001S RS Table 2 1 Packing List 2 2 1 Optional Items The following items are optional accessories for the MODAT 100 ...

Page 24: ...may be charged as needed To start using the MODAT 100 the user must charge the MODAT 100 by the power adapter To charge the MODAT 100 please follow the steps below Step 1 Connect the adapter plug of the power cable to the DC IN port on the bottom panel of the MODAT 100 Figure 2 1 MODAT 100 DC IN Adapter Port Step 2 Plug the power adapter into a power source Step 3 The battery LED lights up red to ...

Page 25: ...he steps below Step 1 Connect the cable to the rear side of the charging cradle the MODAT 100 is only supported by the USB driver from the Windows XP system Step 2 Plug the power adapter to a power source Step 3 Insert the MODAT 100 into the cradle to start charging the battery Step 0 Figure 2 3 Connect the MODAT 100 to the Charging Cradle ...

Page 26: ...n to avoid damage to the card slot The MODAT 100 supports a Subscriber Identity Module SIM and a Security Identification Module SAM card slot To install a SIM or SAM card please follow the steps below Step 1 Push the battery latch out while lifting the cover away A Figure 2 4 Removing the Battery Cover Step 2 Lift the battery out of the battery bay B ...

Page 27: ...SIM card into the left hand slot until the card clicks into place C Step 5 Insert the SAM card into the right hand slot until the card clicks into place C NOTE When inserted properly the card should sit flush with the inside of the MODAT 100 Figure 2 6 Inserting the SIM SAM Card Step 6 Replace the battery Step 7 Replace the battery cover Step 0 ...

Page 28: ... the power button once The start up screen should display Figure 2 7 Power Button Power Off Hold the power button down for a few seconds until the screen shuts off 2 6 Synchronized with Windows 7 System The MODAT 100 can be synchronized with a PC through USB connection To synchronize with the Windows 7 system please make sure to switch the USB mode to RNDIS mode USB to PC in the MODAT 100 To switc...

Page 29: ...MODAT 100 Page 21 Step 2 Go to Start Settings Connections USB to PC Step 3 Check the Enable advanced network functionality option Figure 2 8 USB to PC Window ...

Page 30: ...MODAT 100 Page 22 Appendix A A Safety Precautions ...

Page 31: ...tions are adhered to at all times Follow the electrostatic precautions outlined below whenever the MODAT 100 is opened Make sure the power is turned off and the power cord is disconnected whenever the MODAT 100 is being installed moved or modified Do not apply voltage levels that exceed the specified voltage range Doing so may cause fire and or an electrical shock Electric shocks can occur if the ...

Page 32: ...ritical that whenever the MODAT 100 is opened and any of the electrical components are handled the following anti static precautions are strictly adhered to Wear an anti static wristband Wearing a simple anti static wristband can help to prevent ESD from damaging any electrical component Self grounding Before handling any electrical component touch any grounded conducting material During the time ...

Page 33: ...ors and electrical accessories such as signal cables or power cords When you need to dispose of your display products please follow the guidance of your local authority or ask the shop where you purchased the product The mark on electrical and electronic products only applies to the current European Union Member States Please follow the national guidelines for electrical and electronic product dis...

Page 34: ...oned in the cleaning tips Below is a list of items to use when cleaning the MODAT 100 Cloth Although paper towels or tissues can be used a soft clean piece of cloth is recommended when cleaning the MODAT 100 Water or rubbing alcohol A cloth moistened with water or rubbing alcohol can be used to clean the MODAT 100 Using solvents The use of solvents is not recommended when cleaning the MODAT 100 as...

Page 35: ...MODAT 100 Page 27 Appendix B B International Standards Compliance ...

Page 36: ...1 1 EN 60601 2 The LCD monitor complies with the EN 60601 1 and EN 60601 2 of related European standards B 2 FCC We hereby declare that the equipment specified above conforms to the technical standards as specified in the FCC Rules ...

Page 37: ...MODAT 100 Page 29 Appendix C C Hazardous Materials Disclosure ...

Page 38: ...nces of small quantities of certain materials in the product and is applicable to China RoHS only A label will be placed on each product to indicate the estimated Environmentally Friendly Use Period EFUP This is an estimate of the number of years that these substances would not leak out or undergo abrupt change This product may contain replaceable sub assemblies components which have a shorter EFU...

Page 39: ...d X O O O O X Metal Fasteners X O O O O O Cable Assembly X O O O O X Fan Assembly X O O O O X Power Supply Assemblies X O O O O X Battery O O O O O O O This toxic or hazardous substance is contained in all of the homogeneous materials for the part is below the limit requirement in SJ T11363 2006 X This toxic or hazardous substance is contained in at least one of the homogeneous materials for this ...

Page 40: ... X 风扇组装 风扇组装 风扇组装 风扇组装 X O O O O X 电力供应组装 电力供应组装 电力供应组装 电力供应组装 X O O O O X 电池 电池 电池 电池 O O O O O O O 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ T11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量要求 Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause ha...

Page 41: ...ease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmi...

Reviews: