background image

IFD-NET EVO EMS USER MANUAL 

      rev. 121022EN 

WWW

.IFD-NET.

COM

 

 

M.A.V.

 AVIONIC DIVISION   

V

IA 

L

OMBARDIA  

2,

    

25025

 

M

ANERBIO 

(BS)

 

I

TALY      

HTTP

://

WWW

.

IFD

-

NET

.

COM

 

1

 

 

 
 
 

 

 

 

 

 

 

 

EMS USER GUIDE AND INSTALLATION MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EVOLUTION,

 

THE

 

BEST

 

EVER! 

 

 

Summary of Contents for EVO

Page 1: ...D NET EVO EMS USER MANUAL rev 121022EN WWW IFD NET COM M A V AVIONIC DIVISION VIA LOMBARDIA 2 25025 MANERBIO BS ITALY HTTP WWW IFD NET COM 1 EMS USER GUIDE AND INSTALLATION MANUAL EVOLUTION THE BEST EVER ...

Page 2: ...UAL rev 121022EN WWW IFD NET COM M A V AVIONIC DIVISION VIA LOMBARDIA 2 25025 MANERBIO BS ITALY HTTP WWW IFD NET COM 2 REVISIONS HISTORY Revision Description 06 01 2022 Initial release 12 10 2022 Updated and corrected sections ...

Page 3: ... SETUP MENU 15 4 2 1 MAIN SETUP 16 4 2 2 THERMOCOUPLES SETUP 17 4 2 3 SENSOR SETUP 19 4 2 4 RPM FLOW SETUP 20 4 2 5 MAP VBAT SETUP 21 4 2 6 CURVES SETUP 21 4 2 7 FUEL LEVEL CALIB SETUP 22 4 2 8 ARCS SETUP 22 5 CONNECTIONS 23 5 1 REAR CONNECTORS VIEW AND DESCRIPTION 23 5 2 POWER CONNECTOR 24 5 3 EXPANSION CONNECTORS 24 5 3 1 EXP CONNECTOR EMS1 24 5 3 2 EXP CONNECTOR EMS2 24 5 4 SENSORS AND THERMOCO...

Page 4: ...ALY HTTP WWW IFD NET COM 4 7 ELECTRICAL CONNECTIONS 30 7 1 POWERING AND EXPANSION BUS 30 7 2 EMS POWER CONNECTOR 30 7 3 EMS MASTER SLAVES CONNECTION 31 7 3 1 WIRING SPECIFICATION 31 8 WIRING EXAMPLE 32 9 SYSTEM CONFIGURATION EXAMPLE 33 10 SENSORS LIST 34 11 MECHANICAL DIMENSIONS DIAGRAM 35 12 ORDERING INFORMATION 36 ...

Page 5: ...one other than authorized Seller s representatives EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE LIMITATION OF SELLER S LIABILITY SELLER S LIABILITY TO BUYER FOR ANY LOSS OR CLAIM INCLUDING LIABILITY INCURRED IN CO...

Page 6: ...ile per il volo in condizioni di sicurezza M A V SRL e MAV Technologies Inc declinano ogni responsabilità derivante da un uso improprio del dispositivo in modo che possa violare il volo e le regole di navigazione i regolamenti e la sicurezza DISCLAIMER WARNINGS The information displayed by the family IFD NET EVO is not certified for use for VFR or IFR flights The family IFD NET EVO is meant as an ...

Page 7: ...lly embedded sensors Several types of sensors o CHT o EGT o Oil Temperature o Coolant Temperature o Oil Pressure o Fuel Pressure o Fuel Flow o Fuel Level o RPM o Battery Voltage o Ammeter o CAT o OAT o ABT o MAP o TIT 1 1 ELECTRICAL AND MECHANICAL SPECIFICATION Main power 10 28Vdc 0 8A max with internal filter and peak transient protection Functional temperature range 0 C to 70 C 90 Rh no condensa...

Page 8: ...e rotary switch button Engage the actual focused feature Use it to edit parameters or save those after their modification Rotate big rotary knob crown Has different effects depending on the environment the user is Please refer to below descriptions to deeply understand about this feature Rotate little rotary knob crown Has different effects depending on the environment the user is Please refer to ...

Page 9: ...y knob will show other sensors if set on the low part of the screen The pilot can access the main setup by keeping pressed the knob for about 2 seconds until the screen shown on the right appears Within setups by rotating the little rotary knob s crown moves the selection up and down and tapping button confirms the highlighted selection IFD NET EVO is available in three different models VERSION Th...

Page 10: ...O BS ITALY HTTP WWW IFD NET COM 10 4 OPERATION 4 1 PAGE EMS EMS screen is divided in 4 main areas The following sensors are displayed MAP and RPM indicators CHT EGT and TIT indicators System display only configured sensors adjusting histogram bases OIL P OIL T CT ABT indicators in this order V BAT FUEL LEVEL 1 ...

Page 11: ...Screen In order to setup configuration in this area will appears one or two arc setting indicators Sensor priority is 1 MAP 1 2 RMP 1 3 MAP 2 4 RPM 2 If only one sensor is active the arc appears as a semicircle centered on top of the screen If there are more than two sensors set the remaining are showed in SCREEN SECTION 2 Right Screen and system shown two arc indicator ...

Page 12: ... appears up to four horizontal linear indicators Sensors priority are MAP 2 if not in top screen RPM 2 if not in top screen Oil Pressure OILP Oil Temperature OILT Fuel Pressure FUEL P Fuel Flow F FLOW Coolant Temperature CT Carburetor Air Temperature CAT Cockpit Temperature ABT Outside Air Temperature OAT If there are more than 4 sensors set spinning the big rotary knob will show other sensors fol...

Page 13: ... SCREEN SECTION 3 Left Screen Three types of sensors are shown in this section Up to 6 CHT sensors Up to 6 EGT sensors 1 Turbine Inlet Temperature Graphic dimensions depends to how many sensors are configured This section shows also the maximum actual value per type CHT sensor values are green EGT sensor values are blue and TIT sensor value is white ...

Page 14: ...NET COM 14 4 1 4 SCREEN SECTION 3 Bottom Screen In order to setup configuration in this area will appears up to four vertical linear indicators Sensors priority are 1 Battery Voltage always available and shown 2 Fuel Level 1 3 Fuel Level 2 4 Alternator Current Only sensors correctly configured and calibrated are shown in this section ...

Page 15: ...c symbolic or other 2 Sub Menu Spinning the big rotary knob move cursor between items Spinning the little rotary knob in certain pages i e Thermocouples sensors and others it s possible to scroll between available pages To modify a Parameter 1 Move the cursor on the parameter parameter become GREEN 2 Press the knob Value become GREEN 3 Spin the big rotary knob to enter the desired value 4 Press th...

Page 16: ...he selected engine THERMOCOUPLE Thermocouples setup See 4 2 2 THERMOCOUPLES SENSORS Sensors setup See 4 2 3 SENSOR SETUP RPM FLOW Pulse input setup See 4 2 4 RPM FLOW MAP Manifold setup SET UoM Set unit of measure for physical values VBAT Battery voltage indicator setup SEND DATA Send setup data to slave units SW Software Version EN DATA LOG Data Log setup DATA LOGGER Logger monitor SAVE SETUP Sav...

Page 17: ...onnector EMS1 of the thermocouple to its logical function EXIT Come back to main setup PARAMETER Type of measurement required The available values vary depending on the model TC TYPE Construction type of the thermocouple Available values j k n e r s t See thermocouple data sheet under examination TC TRIM offset value ARCS Set coloured arcs See 4 2 8 ARCS SETUPErrore L origine riferimento non è sta...

Page 18: ...IFD NET EVO EMS USER MANUAL rev 121022EN WWW IFD NET COM M A V AVIONIC DIVISION VIA LOMBARDIA 2 25025 MANERBIO BS ITALY HTTP WWW IFD NET COM 18 ...

Page 19: ...atabase parameter SENS 2 By inserting customized characteristic parameter TYPE and curve parameter CURVE Settings of Sensors menu EXIT Come back to main setup PARAMETER Type of measurement required The available values vary depending on the model TYPE sensor construction technology Valid only if the SENS parameter is not active Possible values V Voltage Sensor I Current Sensor R Resistive Sensor S...

Page 20: ... REVn See 5 3 EXPANSION CONNECTORS Through the RPM FLOW setup it is possible to link the physical input of the sensor to its logical function Logical features availables are 1 RPM rpm motor or rotor 2 F FLOW Fuel Flow Settings of RPM FLOW setup EXIT Come back to main setup PARAMETER Type of measurement required The available values vary depending on the model ARCS Set coloured arcs See 4 2 8 ARCS ...

Page 21: ...rical quantity at the considered point PHIS Value of the physical quantity of the considered point COMPLETE Complete and apply the curve RESET Reset all curve points A color bar at bottom indicates if the curve is correctly configured Every curve must be monotone growing or downwarding Less than 24 points can be entered manually in this case press on COMPLETE copy the actual point until the end Su...

Page 22: ... to 1 10 of the maximum capacity defined in the arcs setup 4 2 8 ARCS SETUP In the arcs setup it is possible to configure the operating areas of the sensors Up to 5 intervals can be configured By adjusting the parameters it is possible to obtain various combinations useful for the description of various types of measurement For example in the case of fuel level sensor with 80Lt tank setting MIN 0 ...

Page 23: ...nnector GPS Antenna Not Used Not present Slot for SD Card Expansion connector 1 MAP2 connector Expansion connector 2 Ground chassis IMPORTANT NOTES ON MAP CONNECTION Ensure that during installation the MAP tubes doesn t develop any twist and or kinks otherwise the MAP indications will not work correctly When fixing the MAP pipes to the instrument please be particularly careful to not twist the 1 8...

Page 24: ...TCp4 Pin 5 TCp5 Pin 6 TCp6 Pin 7 TCp7 Pin 8 TCp8 Pin 9 TCp9 Pin 10 TCp10 Pin 11 TCp11 Pin 12 TCp12 Pin 13 GND Pin 14 TCn1 Pin 15 TCn2 Pin 16 TCn3 Pin 17 TCn4 Pin 18 TCn5 Pin 19 TCn6 Pin 20 TCn7 Pin 21 TCn8 Pin 22 TCn9 Pin 23 TCn10 Pin 24 TCn11 Pin 25 TCn12 Pin 1 GND Pin 2 SE2 Pin 3 SE4 Pin 4 SE6 Pin 5 SE7 Pin 6 SE9 Pin 7 SE11 Pin 8 R2D Pin 9 GND Pin 10 REV1 Pin 11 GND Pin 12 CANBUS L Pin 13 5V Out...

Page 25: ...es are better but also not isolated thermocouples can be used not isolated thermocouples can be affected by ground common mode noise while isolated thermocouples haven t this problem and provide a better signal IFD NET EVO EMS has a differential input who limits this effects Thermocouple configuration type 5 4 2 THERMOCOUPLE WIRING EXAMPLE As described in section 4 2 2 THERMOCOUPLES SETUP it is po...

Page 26: ... sensor output exceeds 5 volts a divider must be connected to the input pins as shown below Typical values Sensor Max Value R1 Value R2 Value 5V No needed No needed 10V 1 5K Ω 1 1 5K Ω 1 5 4 4 CURRENT SENSORS NOTE In case of current sensors connect an electrical resistance in parallel to the sensor the value of which must be set in the setting table of the corresponding sensor Typical values Senso...

Page 27: ...hole keeping in account that the lower right screw hole shall be enlarged to a diameter of 7 5 mm to accommodate the rotary knob The screws on the remaining three holes shall be tightened with appropriate torque in a way to keep the instrument fixed and not introduce any vibration Remove the aluminum knob by turning on the little screw This is because the encoder shaft needs to pass throw the 7 5m...

Page 28: ... 4 x 0 8mm socket hex screwdriver 6mm 6 1 1 DISASSEMBLY STEPS 1 Using a thin blade or fingernail remove frontal cap 2 With a flat blade screwdriver unscrew not completely half turn the screw under the cap and remove the little knob 3 With a socket hex screwdriver unscrew the hex nut not completely about half turn and remove the big knob It is not recommended to completely unscrew the nuts and scre...

Page 29: ...icated transducers Every sensor has a sensitive element which measure a different physical quantity Avoid installing the equipment near hot surfaces A good idea could be to ventilate the rear of the cockpit in order to protect instruments from overheating during exposure of the aircraft to direct sunlight There is plenty of documentation available that explains how to correctly install avionic ins...

Page 30: ...t as possible 7 2 EMS POWER CONNECTOR 1 Main power supply acceptable voltages 10 28Vdc 2 Not Used 3 Not Used 4 A Pole of RS485 BUS 5 Ground Connect to Ground chassis of aircraft or to negative pole of electric circuit 6 Main power supply acceptable voltages 10 28Vdc 7 Not used 8 Ground Connect to Ground chassis of aircraft or to negative pole of electric circuit 9 B Pole of RS485 BUS Pins 1 and 6 ...

Page 31: ...ON The MASTER SLAVE connection has to be made by shielded cable with at least 4 conductors with a section equal to or greater than 0 5mm2 20AWG and less than 1 meter in length In case of lengths greater than 1 meter it is recommended to increase the cable section to 1 mm2 17AWG If several SLAVE units are to be connected it is recommended to separate the bus cable from the power supply see image be...

Page 32: ...5025 MANERBIO BS ITALY HTTP WWW IFD NET COM 32 8 WIRING EXAMPLE 4 EGT thermocouples 4 CHT thermocouples 1 OilT R sensor 1 OilP I sensor 4 20 mA need external resistor 240ohm 1 4w 1 F Lev R sensor 1 FuelP V sensor 0 5V 1 OAT R sensor 1 ABT R sensor 1 CAT R sensor See next for parameter configuration ...

Page 33: ...sensor 1 MAP It is mandatory to set Thermocouple 1 2 3 4 o PARAMETER EGT o TC TYPE K o TC TRIM if needed o ARC Sensors 1 2 3 4 o PARAMETER CHT o TYPE R o SENS ROTAX CHT L or ROTAX CHT R o ARC Sensor 5 o PARAMETER OilT o TYPE R o SENS Rtx OilT o ARCS Sensor 6 o PARAMETER OilP o TYPE I o SENS K456180 o ARCS Sensor 7 o PARAMETER FLev o TYPE R o SENS L E240F33 o ARCS Sensor 8 o PARAMETER FuelP o TYPE ...

Page 34: ...02 GRT LPS 02 FUEL PRESS R 2000 Ω Dynon P N 100413 000 Dy100413 000 CARB TEMP R 100K Ω GRT CARB 01 GRT CARB 01 CARB TEMP R 30K Ω Dynon P N 100468 000 Dy100468 000 CARB TEMP R 500K Ω ROTAX CHT L ROTAX CHT L CHT R 10K Ω ROTAX CHT R ROTAX CHT R CHT R 10K Ω Rotax 801 10 1 Rotax 801 10 1 CHT R 2000 Ω Dynon P N 100409 001 Dy100409 001 COOL T R 80K Ω Chevrolet LS7 Chevrolet LS7 COOL T R 500K Ω Dynon P N ...

Page 35: ...IFD NET EVO EMS USER MANUAL rev 121022EN WWW IFD NET COM M A V AVIONIC DIVISION VIA LOMBARDIA 2 25025 MANERBIO BS ITALY HTTP WWW IFD NET COM 35 11 MECHANICAL DIMENSIONS DIAGRAM ...

Page 36: ...APTER SD CARD Extension Note Please contact vendor for more information about this product and other commercial offers This equipment is not certified and was developed for ultralight and experimental aircraft Must be observed VFR policy during your flight The manufacture doesn t respond for any problem or damage generated by a not properly use of the product Images on this manual are just for exp...

Reviews: