background image

Operating instructions 

AS-i Profinet gateway

AC1401 / AC1402

7390832/00

     04/2014

UK

Summary of Contents for AC1401

Page 1: ...Operating instructions AS i Profinet gateway AC1401 AC1402 7390832 00 04 2014 UK...

Page 2: ...supply 6 5 1 1 Device supply via AUX AS i supply via AS i power supply 6 5 1 2 Device and AS i supply via the AS i power supply 7 5 1 3 Device and AS i supply via one common power supply 7 5 2 Wiring...

Page 3: ...3 UK 9 1 Data sheets 14 9 2 Programming manual 14 10 Maintenance repair and disposal 14 11 Approvals standards 15 12 Scale drawing 15...

Page 4: ...2 Symbols used Instructions Reaction result Designation of pushbuttons buttons or indications Cross reference Important note Non compliance can result in malfunction or interference Information Suppl...

Page 5: ...ies from penetrating 3 Functions and features The AS i Profinet gateway includes one AC1401 or two AC1402 AS i masters one WEB server and a Profinet interface with 2 port switch It controls the exchan...

Page 6: ...he device as indicated on the terminals Ensure an electrical connection between the AS i Profinet gateway terminal FE and the ground of the installation Only insert or remove the AUX jumper when the d...

Page 7: ...E to the ground of the installation The AUX jumper is plugged onto the connector X2 factory setting the device is supplied via AS i line 1 x1 3 and S1 4 5 1 3 Device and AS i supply via one common pow...

Page 8: ...ne 2 AS i 2 2 AS i for AS i line 2 AS i 1 3 AS i for AS i line 1 AS i 1 4 AS i for AS i line 1 FE 5 Functional earth Terminal X2 Combicon 5 08 or AUX jumper Pin Description 24 V 1 24 V device supply 0...

Page 9: ...6 Operating and display elements 6 1 Operating elements 1 LEDs H1 2 LEDs H2 H4 3 Profinet interface 2 RJ 45 4 Profinet interface 1 RJ 45 5 LEDs H3 H5 6 Navigation buttons 7 Softkeys 8 Combicon connec...

Page 10: ...and the connected systems LED status Description The green LED is lit Device has been started There is no warning message There is no error message Yellow LED flashes slowly 0 5 Hz There is a warning...

Page 11: ...nection ok 7 Operation 7 1 Settings During operation the display is switched off after 10 minutes without operation Activate the display by pressing any desired button 7 1 1 Language selection Change...

Page 12: ...12 7 2 Navigation 7 2 1 Navigation elements xxx xxx xxx 1 User level 2 Focus 3 Operating area 4 Softkey labelling 5 Navigation compass 6 Navigation status bar 7 Main navigation bar 8 Info bar...

Page 13: ...fy the parameters of the Profinet interface IP address Subnet mask Gateway address Configuration interface Display modify the parameters of the Ethernet configuration interface DHCP IP address Subnet...

Page 14: ...sed by a warning or error symbol If for one function unit a warning and an error message exist at the same time only the error symbol is displayed Warning message Error message 9 Technical data 9 1 Da...

Page 15: ...15 UK 11 Approvals standards The EC declaration of conformity and approvals can be found at www ifm com 12 Scale drawing 106 2 93 135 5 128 2...