background image

Operating instructions

3-segment signal light

DV13x0
DV23x0

11404095 / 00   06 / 2021

GB

Summary of Contents for DV13 0 Series

Page 1: ...Operating instructions 3 segment signal light DV13x0 DV23x0 11404095 00 06 2021 GB ...

Page 2: ...ignment 8 6 1 1 IO Link device DV23x0 8 6 1 2 Standard device DV13x0 8 7 Operating and display elements 9 8 Operation 10 8 1 Operation of the IO Link version 10 8 1 1 General 10 8 1 2 On Off mode 10 8 1 3 RGB mode 10 8 2 Operation of the standard version 11 8 3 Demo mode 11 9 Parameter setting 12 9 1 IO Link version 12 9 2 Standard version 12 9 2 1 Parameter structure 12 10 Maintenance repair and ...

Page 3: ...als and further information using the QR code on the unit packaging or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note GB ...

Page 4: ...g up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Ò Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability ...

Page 5: ... The LED segments and the audible warning device can be switched on and off individually The unit is not suited for environments with particular requirements on mechanical stability e g shock vibration The unit is intended for indoor use only u Observe the operating conditions Ò Technical data at www ifm com The unit is not approved for safety related tasks in the field of operator protection GB ...

Page 6: ...ink communication interface which enables direct access to process and diagnostic data In addition it is possible to set the parameters of the unit while it is in operation Operation of the unit via the IO Link interface requires an IO Link master With a PC suitable IO Link software and an IO Link adapter cable communication is possible while the system is not in operation The IODDs necessary for ...

Page 7: ...cal surface loosen the screw in the base turn the upper part of the base by 180 and tighten the screw again Attach the base to the fixture overlapping marks on base and fixture and turn clockwise by approx 10 to fix it u Insert the cable through the fixture and if necessary the base and connect the socket with the M12 connector in the signal lamp Tightening torque max 1 Nm Observe the maximum tigh...

Page 8: ... tightening torque of the connection cable 6 1 Pin assignment 6 1 1 IO Link device DV23x0 M12 plug IO Link 4 pole 4 x 0 34 mm AWG 22 4 3 2 1 1 L 2 not used 3 L 4 IO Link 6 1 2 Standard device DV13x0 M12 plug 8 pole 8 x 0 25 mm AWG 24 6 2 1 4 5 7 3 8 1 not used 2 Buzzer DV1310 and DV1330 3 LED segment 3 4 LED segment 2 5 Voltage supply 6 LED segment 1 7 not used 8 IO Link The input polarity is sele...

Page 9: ... Operating and display elements 4 6 2 3 4 5 1 1 Parameter setting button only DV13x0 2 LED segment 1 with 4 RGB LEDs 3 LED segment 2 with 4 RGB LEDs 4 LED segment 3 with 4 RGB LEDs 5 Buzzer only DVx310 and DVx330 6 Feedback LED only DV13x0 GB ...

Page 10: ...ise white yellow off Frequency permanently on low flash rate slow medium fast high flash rate slow medium fast Brightness 100 75 50 25 For the models with an acoustic signal device the audibility of the buzzer can be set 7 6 5 4 3 2 1 0 PDout Seg 3 Seg 2 Seg 1 Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Buzzer sound buzzer style 1 8 Buzzer Byte 5 8 1 3 RGB mode While the unit is operating the controller sw...

Page 11: ...et parameters the LED segments are on and the buzzer sounds if present The signal inputs can be triggered either in PNP or in NPN technology Ò Electrical connection Pin configuration Standard unit With the parameter setting button the following properties can be set for every LED segment Colour red green orange blue purple turquoise white yellow off Frequency permanently on low flash rate slow med...

Page 12: ...ing is selected w The unit indicates the current settings of the LED segment to be configured u Press the parameter setting button for a longer time 5 s to save the selected value for this parameter w The feedback LED flashes green The unit saves the value and goes to the next parameter w After configuration of all LED segments the unit displays the current settings of all LED segments u Briefly p...

Page 13: ...lue 2 Brightness 100 75 50 25 3 Colour red green orange blue purple tur quoise white yellow off Frequency on low flash rate slow low flash rate medium low flash rate fast high flash rate slow high flash rate medium high flash rate fast Brightness 100 75 50 25 GB ...

Page 14: ... voltage supply u Clean the unit from dirt using a soft chemically untreated and dry micro fibre cloth The operation of the unit is maintenance free Only the manufacturer is allowed to repair the unit u After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations ...