background image

Operating instructions 

Flow monitors

SI500A

704544 / 02 

 

 09 / 2017

UK

Summary of Contents for SI500A

Page 1: ...Operating instructions Flow monitors SI500A 704544 02 09 2017 UK...

Page 2: ...n 6 4 Electrical connection 7 5 Operating and display elements 7 6 Set up and settings for water 8 6 1 Change the switch point optional 8 6 2 High flow adjustment optional 9 7 Additional settings opti...

Page 3: ...nted effects in your application That is why installation electrical connection set up operation and mainte nance of the unit must only be carried out by qualified personnel authorised by the machine...

Page 4: ...n applies output open if medium is flowing If the flow speed increases the switching status changes when the switch point is reached If the flow speed falls again the switching status changes if the v...

Page 5: ...ion location General 12mm The sensor tip is to be completely sur rounded by the medium Insertion depth of the sensor minimum 12 mm Recommended For horizontal pipes mounting from the side For vertical...

Page 6: ...of interference 3 3 Mounting operation Ensure that the system is free of pressure during installation Ensure that no media can leak at the mounting location during installa tion 1 2 3 Grease the thre...

Page 7: ...PELV Disconnect power Connect the unit as follows Core colours of ifm sockets 1 BN brown 3 BU blue 4 BK black 5 Operating and display elements 1 Operation display The green LEDs indicate the current...

Page 8: ...2 3 Your normal flow exceeds the representation range of the display LED 9 flashes Carry out high flow adjustment 6 2 You can restore the factory setting any time 7 3 6 1 Change the switch point optio...

Page 9: ...you should additionally adapt the unit to the minimum flow Note The following adjustment must only be carried out after the high flow adjust ment Let the minimum flow circulate in the installation or...

Page 10: ...taneously for at least 10 s in the operating mode The indication goes out the unit locks or unlocks On delivery unlocked 8 Error during adjustment If no adjustment is possible all LEDs flash red The u...

Page 11: ...the representation range LED 0 flashes current flow far below the represen tation range Interference indicators Short circuit at the switching output The operating indicator and red LEDs light alterna...

Page 12: ...on 3 tightening torque 25 Nm 12 Technical data Application area Liquids and gases Operating voltage V 19 36 DC1 Current rating mA 250 Short circuit protection pulsed reverse polarity overload protecti...

Page 13: ...ating IP 67 Protection class III Shock resistance g 50 DIN IEC 68 2 27 11 ms Vibration resistance g 20 DIN IEC 68 2 6 55 2000 Hz Housing materials stainless steel 316L 1 4404 stainless steel 304 1 430...

Reviews: