Ultrasonic diffuse-reflection sensor 

with IO-Link 

UGT203 

UGT206 

UGT509 

UGT512 

80275568 / 00 

 

05 / 2018

UK

Summary of Contents for UGT203

Page 1: ...Operating instructions Ultrasonic diffuse reflection sensor with IO Link UGT203 UGT206 UGT509 UGT512 80275568 00 05 2018 UK ...

Page 2: ... caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator Protect units and cables against damage 2 Functions and features Ultrasonic sensor for monitoring levels and detecting objects 3 Installation 3 4 1 2 Secure the unit to...

Page 3: ...are set via the IO Link interface 5 1 or the teach button 5 2 5 1 IO Link This unit has an IO Link communication interface which enables direct access to process and diagnostic data In addition it is possible to set the parameters of the unit while it is in operation Operation of the unit via an IO Link interface requires an IO Link master With a PC suitable IO Link software and an IO Link adapter...

Page 4: ...w status LEDs 1 2 flash 2 5 Hz P1 setting is completed Position the object in P2 Fig 1 or 2 Press the teach button for 1 s Yellow status LEDs 1 2 flash briefly 4 Hz P2 setting is completed 5 2 3 Invert output response Press the teach button for 6 s Yellow status LEDs 1 2 flash 10 Hz Yellow status LEDs 1 2 flash briefly 4 Hz Output function is inverted 5 2 4 Restore factory setting Align the unit s...

Page 5: ...s Complementary switching outputs 1 1 B P2 P1 1 0 0 3 4 2 B P1 P2 2 1 0 1 0 1 3 4 Inverted switching outputs Inverted switching outputs 1 1 B P2 P1 1 0 0 2 3 4 1 1 B P1 P2 1 0 0 2 3 4 1 output response 2 distance to the object 3 OUT1 switching output 4 OUT2 switching output B blind zone P taught position T teach button Technical data and further information at www ifm com ...