background image

User Guide 

CUG00028-EN-A01

 

 

 

 

 

 

 
 
 
 
 
 
 

USER GUIDE 

Wireless temperature data logger LT2 

 
 

    

 

 

 
 
 

 
 

 

This device complies with FCC RF radiation exposure limits set forth 

for general population (uncontrolled exposure). This device must be 

installed to provide a separation distance of at least 20cm from all 

persons and must not be collocated or operating in conjunction with 

any other antenna or transmitter.

 

 

Summary of Contents for LT2

Page 1: ...omplies with FCC RF radiation exposure limits set forth for general population uncontrolled exposure This device must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter ...

Page 2: ...nstructions 3 1 3 Battery Safety 3 1 4 Warning to users in the United States 4 1 5 Warning to users in Canada Attention pour les utilisateurs au Canada 4 2 Introduction 6 3 Necessary equipments 6 4 Configuration of the logger using the software IJITempLab 4 7 7 4 1 Launch the software IJITempLab 4 7 and connect to the data logger to configure 7 4 2 Displaying the measures 8 4 3 Data export 9 4 4 M...

Page 3: ...electrostatic loads before opening and manipulate the devices by touching a metallic surface linked to the Earth 1 3 Battery Safety This product contains a lithium battery that must be disposed of properly Please follow the battery safety items below Do not dismantle open or shred secondary cells or batteries Do not expose cells or batteries to heat or fire Avoid storage in direct sunlight Do not ...

Page 4: ...m IJINUS Unauthorized modification may void the equipment authorization from the FCC and will void the IJINUS warranty This device complies with FCC RF radiation exposure limits set forth for general population uncontrolled exposure This device must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other ...

Page 5: ...ques de brouillage radioélectrique à l intention d autres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente p i r e ne dépasse pas l intensité nécessaire à l établissement d une communication satisfaisante Cet appareil doit être installé de manière à assurer une distance de séparation d au moins 20 cm avec toutes les personnes Il ne ...

Page 6: ...sary equipments LT2 temperature M0C0000 2 WIJIKEY 2 A0G00010 Data Logger Programming kits including Non rechargeable lithium the software IJITempLab battery 3 6V 2 6Ah for LT2 The LT2 data logger has an internal battery To check or activate the radio connection you can press the front button The LED flashes green by period every x seconds depending on configuration This LED indicates that a radio ...

Page 7: ...ance is needed between the Wiji antenna and the datalogger for a correct radio connection Click the Connect button so the software recognize the Wiji as a radio access point If it doesn t work you can install the drivers from the top main menu then Tools and Install the Wiji driver Once connected you have to click the Refresh visible sensors and choose from the list the available sensors nearby Th...

Page 8: ...ill appear confirming the recording state 4 2 Displaying the measures From the graph and or list of data you find the tab Export the measures with the choice of different files format and style You have 3 options to retrieve the data Once retrieved they are displayed on the graph You can zoon into the graph with your cursor clicked By passing your cursor along the curve you are able to check the m...

Page 9: ...e different ways of exporting the data You can export the measures directly from the graph by right clicking on it choosing from this menu Export to csv The same option is available from the top menu Choose File and Export to csv Finally to automatically export the data choose a directory like bellow example 4 4 Menu options From the File menu you can Export data to csv Import a configuration file...

Page 10: ...3 30 Customer Service 33 2 98 09 03 32 sav ijinus com 10 From the Tools menu you can Install the Wiji driver or uninstall it Change the sensor resolution as desired Change the memory recording mode Retrieve a sensor configuration From the View menu you can hide the parameters to reveal the graph only in a bigger size ...

Page 11: ...JINUS 25 ZA de Kervidanou 3 29300 MELLAC France 33 2 98 09 03 30 Customer Service 33 2 98 09 03 32 sav ijinus com 11 5 Revision of the document Date Revision Writer s Modifications 11 21 2019 2A01 D MAHE A TRIBALLIER Creation of the document and translation ...

Reviews: