background image

 

 

iMcV-Modules 

Operation Manual 

   

   

 

 

Above illustrations are representative; some minor differences may be present in actual product 

 

Summary of Contents for iMcV-S2MM/1250

Page 1: ...iMcV Modules Operation Manual Above illustrations are representative some minor differences may be present in actual product...

Page 2: ...ructions and directions for a period of six 6 years after the original date of purchase This warranty is subject to the limitations set forth below At its option IMC Networks will repair or replace at...

Page 3: ...arranty ii About the iMcV Modules 1 Installation 1 LED Operation 2 Configuration Instructions 4 Installation Troubleshooting 9 Specifications 9 IMC Networks Technical Support 10 Fiber Optic Cleaning G...

Page 4: ...rent wavelengths 1310 nm and 1550 nm doubling the capacity of fiber Includes one RJ 45 connector and one SC fiber connector iMcV S2MM M2MM S2SM Protocol independent modules provide a single conversion...

Page 5: ...reen when unit has power LNK RJ 45 Glows green if link is established on the twisted pair port located on RJ 45 ACT RJ 45 Glows amber when data is being passed on the twisted pair located on RJ 45 LNK...

Page 6: ...data FA Glows green when FiberAlert is enabled FiberAlert is not available applicable on single strand versions of iMcV LIM LEDs on iMcV S2MM S2SM M2MM The LED functions on iMcV S2MM S2SM M2MM are as...

Page 7: ...naged chassis is configured via the software it will operate using the hardware configuration Unmanaged Modules Before beginning installation of the iMcV Modules configure them for the desired feature...

Page 8: ...t and Pulsing FiberAlert Some iMcV Modules include advanced troubleshooting features that help locate silent failures on the network Troubleshooting features include iMcV LIM TX FX and TX SSFX 30 Boar...

Page 9: ...transmitters but normally has no way of knowing whether the cable to the other device is intact and the link pulses are reaching the other end The combination of FiberAlert and LinkLoss allows this in...

Page 10: ...the loss of one strand of fiber If a strand is unavailable the IMC Networks device at the receiver end notes the loss of link The device will then stop transmitting data and start sending link pulses...

Page 11: ...connection set the push button to a position that makes the twisted pair LNK link LED glow Auto Negotiation on iMcV LIM iMcV LIM Modules include the feature Auto Negotiation When Auto Negotiation is...

Page 12: ...r by itself first make sure to have an appropriate fiber patch cable then follow these steps to test 1 Connect the media converter to the twisted pair device with a twisted pair cable 2 Loop a single...

Page 13: ...10 IMC Networks Technical Support Tel 949 465 3000 or 800 624 1070 in the U S and Canada 32 16 550880 Europe Fax 949 465 3020 E Mail techsupport imcnetworks com Web www imcnetworks com...

Page 14: ...between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product a...

Page 15: ...f separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local a...

Page 16: ...The information in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document iMcV Modules is a trademark of IMC Networks...