background image

 

  No.57, Ln. 350, Nanshang Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.)

 

 

Tel:+886-3-322-9898

    Fax:+883-3-321-1992   

Http://www.in-win.com

     

 

 

 

 

 
 

 

 

 

 

 

In Win 

 

 

 

 

 

 

Storage Chassis 

8-Port 6Gb/s 3.5”   

Mini-SAS Backplane 

 
 

 

User’s Manual 

 

2014/3/6

Summary of Contents for Port 6Gb/s 3.5"

Page 1: ...7 Ln 350 Nanshang Rd Guishan Dist Taoyuan City 333 Taiwan R O C Tel 886 3 322 9898 Fax 883 3 321 1992 Http www in win com 1 In Win Storage Chassis 8 Port 6Gb s 3 5 Mini SAS Backplane User s Manual 2014 3 6 ...

Page 2: ...fications are therefore subject to change without prior notice Information provided in this manual is intended to be accurate and reliable However IN WIN DEVELOPMENT INC assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use Technical Support In win works hard to offer our customers maximum performance from our chassis But in ...

Page 3: ... product is subject to change without prior notice In Win Development Inc reserves the right to make final modifications 3 Contents Technical Support Copyright Revision History Backplane Specification Backplane Layout Backplane Assembly ...

Page 4: ...tual product is subject to change without prior notice In Win Development Inc reserves the right to make final modifications 4 Revision History Date Modification Jan 22 2013 First release V1 0 Mar 06 2014 modify back plane P N V1 1 ...

Page 5: ...L LED GREEN RED WHEN HDD R W ACTIVE GREEN WHEN HDD FAIL ACTIVE RED ACCESS SINNAL Always from device HDD FAIL SIGNAL INPUT CONNECTOR 1 ON BOARD SENSOR 1 Temperature setting 29 fan speed 70 39 fan speed 100 Temperature Alarm 47 When the temperature is less than the temperature of 44 C automatic discharge alarm FAN SPEED CONTROL 2 TYPE A AUTO By Temperature B MANUAL a 60 60 of the max fan speed b 80 ...

Page 6: ...anual The actual product is subject to change without prior notice In Win Development Inc reserves the right to make final modifications 6 Backplane Layout A Power Connector x 3 Pin No Descriptions 1 12V 2 GND 3 GND 4 5V ...

Page 7: ... No Jumper on P3 P8 Default rpm from 70 29 to 100 39 3 4 Short Fan speed max 60 by temperature control Fan speed Minimize about 42 to Maximize 60 5 6 Short Fan speed max 60 by temperature control Fan speed Minimize about 42 to Maximize 60 7 8 Short Temperature Fault set 55 D HDD Fail signal input Pin No Descriptions 1 Fan PWN Output 2 Fan Clock Input 3 12V 4 GND Pin No Descriptions 1 HDD1 2 HDD2 3...

Page 8: ... for HDD 1 4 E2 for HDD 5 8 F Fan fail control pin B P to B P can be connected by cable to link function When one fan fail in any three B P the others fan will be full speed Cable P N 3RAMRW026200 G Mini SAS connector x2 Led Indicator Pin No Descriptions 1 2 short SGPIO Disable 2 3 short SGPIO Enable LED Status Color Power Led Power On Blue HDD Led Active Green HDD Led Fail Red ...

Page 9: ...ange without prior notice In Win Development Inc reserves the right to make final modifications 9 Backplane Layout The In Win 8 Port 6Gb s Backplane can be assembled on In Win Storage Server Chassis RS224 02 Please refer to the chassis Quick Installation Guide ...

Reviews: