background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Z4010 

Installer manual 

 

Summary of Contents for Pleats

Page 1: ...Z4010 Installer manual ...

Page 2: ...e 12 11 End Call Lock Button 13 12 Factory data reset 13 13 Advanced Settings 13 13 1 Device 13 13 1 1 Visibility 13 13 1 1 1 Functions 13 13 1 1 2 Entrance panels 13 13 1 1 3 Video door entry systems 13 13 1 1 4 Switchboards 13 13 1 2 Buttons mapping 13 13 1 3 SOS 13 13 1 4 Doctor mode 13 13 1 5 Intercom Groups 13 13 1 6 Save configuration 14 13 2 System 14 13 2 1 System language 14 13 2 2 Date a...

Page 3: ... when the user gets near to it Through the backlit soft touch buttons it is possible to interface with the video door entry system Backlit buttons and proximity sensor are not available in the low cost version Z4000 L PLEATS Z4010 allows to make and receive intercom and SIP calls it allows to receive calls from external entrance panels and to self start them It is possible to exploit the video doo...

Page 4: ...4 EN Pleats 1 2 Front view 1 3 Rear view Proximity sensor Colour LCD display Microphones Programmable touch buttons Speaker Ethernet connector Auxiliary Connectors ...

Page 5: ...5 EN Pleats 1 4 Side and bottom view Volume buttons Mini USB connector Reset button ...

Page 6: ...6 EN Pleats 1 5 Description of buttons 2 3 4 5 6 7 8 9 10 1 ...

Page 7: ...used for the light on video door entry system function 8 Call button Used to answer silence close a call 9 Volume button In the menus it is used for scrolling While typing to display additional characters 10 Volume button In the menus it is used for scrolling While typing to display additional characters Button combinations Button and button Activate Deactivate the do not disturb mode Button and b...

Page 8: ...ration mounting plate and two M3 screws 2 Unified rectangular wall mounted box with 3 modules in vertical configuration mounting plate one M3 screw two self tapping screws and two wall plugs 3 Round wall mounted box with 60mm diameter mounting plate and two M3 screws 4 Corrugated pipe without wall mounted box two self tapping screws and two wall plugs Screws dowels and mounting plate are supplied ...

Page 9: ...of the mounting plate 4 Slide the video door entry system down to lock it on the mounting plate To remove the video door entry system it is necessary to slide it upwards and then remove it from the support For the connection diagrams refer to the CONNECTION DIAGRAMS section located in the contents CAUTION The video door entry system must be located away from light and heat sources Installation Hei...

Page 10: ...pply is not available 24VDC Positive 24V 24VDC Negative 24V M Common mass CH 12 24V AC DC relay contact The two terminals marked CH are a normally open contact FP Landing call AL Generic alarm P Panic button Ethernet connector Connector used for data traffic and POE power supply 4 Maintenance Clean the product using a soft cloth do not pour water on the device and do not use any type of chemical p...

Page 11: ... connectors Tester for ethernet cables Procedure 1 Strip the cable about 10mm taking care not to damage the insulation of the individual cables 2 Sort the cables as shown in the figure and even them up cutting the excess 3 Insert the cables into the RJ45 connector Check that the order of the cables remains unchanged after inserting the connector 4 Crimp the cable using the appropriate clamp making...

Page 12: ...or calls Ringtone for calls from entrance panels Intercom calls Ringtone for intercom calls Notification sounds Ringtone for notifications To set the desired ringtone it is necessary to select it from the list 5 2 Volume It is possible to change the ringtone volume and the call volume An indicator will be shown on which it is possible to act to adjust the volume Ringtone Speaker volume for rington...

Page 13: ...devices to make visible to the PLEATS video door entry system Then tick the desired devices and press done 13 1 1 1 Functions It is possible to select the video door entry functions to make visible to the PLEATS video door entry system Then tick the desired devices and press done 13 1 1 2 Entrance panels It is possible to select the external entrance panels to make visible to the PLEATS video door...

Page 14: ...de Through this setting it is possible to activate the master mode Activating the master mode only the master devices will be visible i e those with Object ID that ends with 00 Example of master device 010000000100 13 2 5 Power supplies It is possible to activate the video door entry functions of the power supplies Z6001 Z60DT in the system Pressing Power Supplies will display the power supplies t...

Page 15: ...hone AUX3 AUX3 free PORTE RJ45 AL GND N GND GND GND INPUT GND INPUT S Lock return COM 1 COM 2 COM 3 USB IN4 PW PW Power 12V Relay additional chime CH2 USB M Relay additional chime Power Video door phone Entrance panel Video door phone CONNECTION DIAGRAMS 1 Single family video door entry system Composed of an external entrance panel a power supply and an internal video door entry system WIRING SPEC...

Page 16: ...AUX2 12Vcc 1A Lock Power Supply Z6001 RJ45 IN1 P2 AUX3 PORTE RJ45 GND N GND GND S Lock return COM 1 COM 2 COM 3 USB IN4 Video door phone 2 Entrance panel Video door phone 2 P CH1 FP RJ45 AL PW PW CH2 USB M 2 P CH1 FP RJ45 Panic Button Alarm INPUT GND Outdoor call button AL PW PW Power 12V Relay additional chime CH2 USB M Relay additional chime Power Panic Button Alarm INPUT GND Outdoor call button...

Page 17: ...G SPECIFICATIONS CLAMP CABLE MAX LENGTH CONNECTOR P1 P2 P3 P4 Eth CAT5 or higher 100 metres RJ45 S S 1 5mm2 100 metres IN1 2 3 4 1mm2 100 metres With 10W lock Entrance panel Video door phone 1 CAT5 CAT5 CAT5 RJ45 Video door phone 2 with internet connection HOME INTERNET 12Vcc 1A Lock 1 2 P CH1 FP AL PW PW CH2 USB M 2 P CH1 FP AL PW PW CH2 USB M FIREWALL Distributor Z600F Power Supply Z6001 Interne...

Page 18: ... P1 P2 P3 P4 Eth CAT5 or higher 100 metres RJ45 S S 1 5mm2 100 metres IN1 2 3 4 1mm2 100 metres With 10W lock Entrance panel CAT5 CAT5 RJ45 12Vcc 1A Lock CAT5 CAT5 Video door phone 1 2 P CH1 FP AL PW PW CH2 USB M 2 P CH1 FP AL PW PW CH2 USB M Video door phone Video door phone Di str ib ut or Z 60 D V Distributor Z60DV Distributor Z60DV Power Supply Z6001 Video door phone Internet of building Condu...

Page 19: ... CLAMP CABLE MAX LENGTH CONNECTOR P1 P2 P3 P4 Eth CAT5 or higher 100 metres RJ45 S S 1 5mm2 100 metres IN1 2 3 4 1mm2 100 metres With 10W lock CAT5 CAT5 CAT5 Video door phone 12Vcc 1A Lock CONCIERGE INTERNET of building Entrance panel 12Vcc 1A Lock 1 1 2 P CH1 FP AL PW PW CH2 USB M Video door phone Distributor Z60DV Distributor Z60DV Power Supply Z6001 Distributor Z60DT ...

Page 20: ...e Video door phone Contact Push button Sensor 2 P CH1 FP RJ45 AL PW PW CH2 USB M 2 P CH1 FP RJ45 AL PW PW CH2 USB M 2 P CH1 FP RJ45 AL PW PW CH2 USB M ALLARM INPUT to concierge Power supply 12 Vdc Video door phone Panic Button Alarm INPUT GND Outdoor call button Power 12V Relay additional chime Relay additional chime Power Panic Button Alarm INPUT GND Outdoor call button Power 12V Relay additional...

Page 21: ... P3 P4 P5 IN2 Stair light IN3 IN2 S AUX1 AUX2 12Vcc 1A Lock AUX1 Stair light 2A 24Vdc AUX2 Driveway gate Power Supply Z6001 IN1 P2 AUX3 AUX3 free PORTE RJ45 GND N GND GND GND S Lock return COM 1 COM 2 COM 3 USB IN4 STAIRS LIGHT CONTOL P1 L P3 P4 P5 IN3 IN2 S AUX1 AUX2 12Vcc 1A Lock Power Supply Z6001 IN1 Lock release IN1 P2 AUX3 PORTE RJ45 GND N GND GND GND INPUT S COM 1 COM 2 COM 3 USB IN4 wire 1...

Page 22: ...22 EN Pleats Installer notes ...

Page 23: ...23 EN Pleats Installer notes ...

Page 24: ...voltage supplied by the distribution network Before carrying out maintenance operations disconnect the appliance from the mains power supply In case of failure or malfunction of the appliance turn off the power and contact the service centre Do not obstruct the ventilation openings or slots in the power supplies Directive 2012 19 EU WEEE RAEE The crossed out bin symbol indicates that the product m...

Page 25: ...InfinitePlay S r l Via Antonio Ferrero 9 35133 Padova PD ITALY Tel 049 706344 www infiniteplay com ENG 18901080 RL05 03 18 INFINITEPLAY ITALY ...