IUP & IUR quick start 
and installation 
guide 

 

 

Product: iUR2xx/iUP2xx 

Rev:1  

 

Save this Information Leaflet and file in a safe place! 

1.

 

Introduction 

Thank you for choosing a payment terminal Ingenico. 
We recommend you to read carefully this installation guide: It gives you 
the necessary information about safety precautions, unpacking, 
installation, and maintenance of your terminal. 

WARRANTY / SECURITY 

To benefit from the guarantee-related product, and to respect the security, 
we  ask  you  to  use  only  accessories  delivered  in  box  with  the  product, 
entrusting maintenance operations only to an authorized person. 
GARANTIE / SICHERHEIT  
Um das mit der Garantie verbundene Erzeugnis nutzen und die Sicherheit 
wahren  zu  können,  bitten  wir  Sie,  nur  die  mit  dem  Erzeugnis  in  der 
Verpackung 

gelieferten 

Zubehörteile 

zu 

verwenden 

und 

die 

Wartungsarbeiten einer dazu berechtigten Person anzuvertrauen. 

 

The  iUP250  can  be  powered  by  different  sources  please  respect  these 
recommendations:

  

 

12  –  30  volts  DC  alimentation  must  be  compliant  with  international 
standard IEC60950- 

12 – 30 V 

3A 

The  iUR250  is  powered  by  USB  powered;  it  must  be  connected  to  a  full 
compatible USB link.  

 

 

 

 

USB 5V 

 500 mA 

Ground slud must be used to connect the products to the earthing. 

Nota: Failure to comply with these instructions will void the manufacturer’s 

responsibility. 

 

 

This symbol indicates an important Warning. 
Dieses Symbol stellt ein wichtiges Warnzeichen dar. 

 

2.

 

Recomendation 

2.1.

 

Safety 

Power on/Power down  

To power on or power down the iUP 250 connect or disconnect the cable 
connected to the MDB slave port 12-30V  
To power on or power down the iUP 250 connect or disconnect the cable 
connected to the host  
  
Lithium battery 
The iUR250 /iUP250 is fitted with a lithium battery which is not accessible 
to the user. Only a qualified technician may be authorized to open the unit 
and change this component. 
For 

switzerland

 annex 2.15 of SR 814.81 applies for batteries. 

 
SAM, MMC, SIM and RF connectors 
There are operator accessible replacement parts. 
This is an Electrostatic (ESD) sensitive area and ESD precautions must 
be taken when fitting it As a minimum, the operator should be 
"Electrostatically Discharged" via his/her hand to a suitable 
safe metallic earthing point prior to opening this area. 

2.2.

 

Security of your terminal 

Upon receipt of your terminal you should check for signs of tampering of 
the equipment. It is strongly advised that these checks are performed 
regularly after receipt. You should check, for example: that the keypad is 
firmly in place; that there is no evidence of unusual wires that have been 
connected to any ports on your terminal or associated equipment, the chip 
card reader, or any other part of your terminal. Such checks would provide 
warning of any unauthorised modifications to your terminal, and other 
suspicious behaviour of individuals that have access to your terminal. 
Your terminal detects any “tampered state”. In this state the terminal will 
repeatedly flash the message” Alert Irruption!” and further use of the 
terminal will not be possible. If you observe the “Alert Irruption!” message, 
you should contact the terminal helpdesk immediately. 
You are strongly advised to ensure that privileged access to your terminal 
is only granted to staff that have been independently verified as being 
trustworthy. 

2.3.

 

Integration (see installation 

guide *) 

The integration must be done to be compliant with PCI requirement. 
 
Payment  Card  Industry  –  PIN  Transaction  Security  (PTS)  -  Modular 
Derived Test Requirements Version 3.1 october 2011 
 
Positioning of IUP250 on the unattended device must be in such way as to 
make  keypad  spying  difficult  (according  to  PCI  PTS  -  Modular  Derived 
Test Requirements Version 3.1 october 2011). 
 If  the  unattended  device  doesn’t  provide  such  protection,  an  Ingenico 
privacy shield option can be provided. 
 
iUP250  and  iUR250  must  be  mounted  on  the  unattended  machine  as 
indicated in the installation guide to activate removal detector. 
 
CAUTION 
NEVER ask the customer to divulge their PIN Code. Customers 
should be advised to ensure that they are not being overlooked when 
entering their PIN Code

 

 

 