INSTRUCTIONS FOR

MODEL PF150 HIGH PERFORMANCE

HIGH--SPEED SANDER

Model PF150 High--Speed Sander is designed for light sanding, feather edging and rust removal.

Ingersoll--Rand is not responsible for customer modification of Powerforce tools for applications on

which Ingersoll--Rand was not consulted.

IMPORTANT SAFETY INFORMATION ENCLOSED.

READ THIS MANUAL BEFORE OPERATING TOOL.

FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.

PLACING TOOL IN SERVICE

Always operate, inspect and maintain this tool in

accordance with all regulations (local, state,

federal and country), that may apply to hand

held/hand operated pneumatic tools.

For safety, top performance, and maximum

durability of parts, operate this tool at 90 psig

(6.2 bar/620 kPa) maximum air pressure at the

inlet.

Always turn off the air supply and disconnect the

air supply hose before installing, removing or

adjusting any accessory on this tool, or before

performing any maintenance on this tool.

Do not use damaged, frayed or deteriorated air

hoses and fittings.

Keep clear of whipping air hoses. Shut off the

compressed air before approaching a whipping air

hose.

Be sure all hoses and fittings are the correct size

and are tightly secured. See Dwg. TPD905--1 for a

typical piping arrangement.

Always use clean, dry air at 90 psig

(6.2 bar/620 kPa) maximum air pressure. Dust,

corrosive fumes and/or excessive moisture can ruin

the motor of an air tool.

Do not lubricate tools with flammable or volatile

liquids such as kerosene, diesel or jet fuel.

Do not remove any labels. Replace any damaged

label.

USING THE TOOL

Always wear eye protection when operating or

performing maintenance on this tool.

Always wear hearing protection when operating

this tool.

Keep hands, loose clothing, long hair and jewelry

away from working end of tool.

Keep body stance balanced and firm. Do not

overreach when operating this tool. Anticipate and

be alert for sudden changes in motion, reaction

torques, or forces during start--up and operation.

Tool shaft may continue to rotate briefly after

throttle is released.

Check for excessive speed and vibration before

operating.

Air powered tools can vibrate in use. Vibration,

repetitive motions or uncomfortable positions may

be harmful to your hands and arms. Stop using any

tool if discomfort, tingling feeling or pain occurs.

Seek medical advice before resuming use.

Use accessories recommended for Powerforce by

Ingersoll--Rand.

These Sanders will operate at the free speed

specified on the nameplate if the air supply line

furnishes 90 psig (6.2 bar/620 kPa) air pressure at

the tool. Operation at higher air pressure will

result in excessive speed.

Use only a sanding pad, bonnet with these tools. Do

not use any grinding wheel, burr, cutting off tool or

metal removing accessory with these tools. Never

use an accessory having a maximum operating

speed less than the free speed of the Sander in

which it is being used.

This tool is not designed for working in explosive

atmospheres.

This tool is not insulated against electric shock.

Wear gloves and protective clothing while

operating this tool.

Do not carry or drag the tool by the cord or cable.

Prevent exposure and breathing of harmful dust

and particles created by power tool use:

Some dust created by power sanding, sawing,

grinding, drilling and other construction

activities contains chemicals known to cause

cancer, birth defects or other reproductive

harm. Some examples of these chemicals are:

-- lead from lead--based paints,

-- crystalline silica from bricks and cement

and other masonry products, and

-- arsenic and chromium from chemically

treated lumber.

Your risk from these exposures varies,

depending on how often you do this type of

work. To reduce your exposure to these

chemicals: work in a well ventilated area, and

work with approved safety equipment, such as

those dust masks that are specially designed to

filter out microscopic particles.

The use of other than genuine Powerforce by Ingersoll--Rand replacement parts may result in safety hazards, decreased

tool performance, and increased maintenance, and may invalidate all warranties.
Repairs should be made only by an authorized Powerforce Servicenter. Call toll free 1 (866) 207-6923.

F
E

US

Summary of Contents for POWERFORCE PF150

Page 1: ...or forces during start up and operation Tool shaft may continue to rotate briefly after throttle is released Check for excessive speed and vibration before operating Air powered tools can vibrate in use Vibration repetitive motions or uncomfortable positions may be harmful to your hands and arms Stop using any tool if discomfort tingling feeling or pain occurs Seek medical advice before resuming u...

Page 2: ...nsitive sandpaper 2 Resin back paper installation Insert pad nut 20 through sandpaper and backing pads 19 Make sure the recessed center of the pads face the sander Warning Backing pads 19 should be inspected for signs of irregularities such as fractures excessive wear nicks cuts at the edges of center hole Pads showing such characteristics should not be used Always use both packing pad with the 3 ...

Page 3: ... will not function System leakage Ensure connections are tight and hoses are not damaged Low speed or tool will not function Debris build up in tool Flush tool with 1 5 cc of Power force oil 50 Low speed Regulator not fully open Turn regulator to adjust the tool speed to maximum speed Low speed Clogged or dirty Exhaust filter Clean out exhaust by unscrewing muffler Clean muffler and reinstall SPEC...

Page 4: ... to which this declaration relates is in compliance with the provisions of Directives By using the following Principle Standards Serial No Range D Vose Patrick Livingston Name and signature of authorised persons Name and signature of authorised persons Date Date SAVE THESE INSTRUCTIONS DO NOT DESTROY When the life of the tool has expired it is recommended that the tool be disassembled degreased an...

Page 5: ...rage et de l exploitation La rotation des accessoires de l outil peut continuer pendant un certain temps après le relâchement de la gâchette Vérifier que la vitesse et les vibrations ne sont pas excessives avant d utiliser l outil Les outils pneumatiques peuvent vibrer pendant l exploitation Les vibrations les mouvements répétitifs et les positions inconfortables peuvent causer des douleurs dans l...

Page 6: ...port résine Insérez l écrou de plateau 20 dans le disque de papier et les plateaux de support 19 Vérifiez que le centre lamé fait face à la ponceuse Avertissement Les plateaux de ponçage 19 doivent tout d abord être inspectés pour tout signe d irrégularités telles que des amorces de rupture usure excessive encoches coupures sur la périphérie ou autour du trou central Les plateaux présentant de tel...

Page 7: ...ou l outil ne fonctionne pas Fuite du circuit Vérifiez que les raccords sont bien serrés et que les flexibles ne sont pas endommagés Faible vitesse ou l outil ne fonctionne pas Accumulation de débris dans l outil Rincez l outil avec 1 5 cm d huile Powerforce No 50 Basse vitesse Régulateur pas complètement ouvert Tournez le régulateur pour obtenir la vitesse maximum de l outil Basse vitesse Filtre ...

Page 8: ...rtificat est conforme aux prescriptions des Directives en observant les normes de principe suivantes No Serie D Vose Patrick Livingston Nom et signature des chargés de pouvoir Nom et signature des chargés de pouvoir Date Date NOTE CONSERVEZ SOIGNEUSEMENT CES INSTRUCTIONS NE PAS LES DÉTRUIRE A la fin de sa durée de vie il est recommandé de démonter l outil de dégraisser les pièces et de les séparer...

Page 9: ...n u otras fuerzas durante la puesta en marcha y utilización El eje de la herramienta puede seguir girando brevemente después de haberse soltado la palanca de mando Antes de utilizar la herramienta compruebe que ésta no funcione con exceso de velocidad o vibración Las herramientas neumáticas pueden vibrar durante el uso La vibración los movimientos repetitivos o las posiciones incómodas pueden daña...

Page 10: ...e del papel con soporte de resina Introduzca la tuerca del disco 20 por el papel de lija y los discos soporte 19 Asegúrese de que el centro ahuecado de los discos quede hacia la lijadora Aviso Los discos soporte 19 se deberán examinar en busca de señales de irregularidades como fracturas desgaste excesivo o cortes en los bordes del orificio central Los discos que manifiesten alguna de estas caract...

Page 11: ... funciona a baja velocidad Fugas del sistema Verificar que las conexiones estén apretadas y que las mangueras no estén dañadas La herramienta no funciona o funciona a baja velocidad Acumulación de residuos en la herramienta Hacer pasar por la herramienta 1 5 de aceite Powerforce Nº 50 Velocidad baja El regulador no está abierto del todo Girar el regulador para ajustar la velocidad de la herramient...

Page 12: ...os que se refiere la presente declaración cumplen con todo lo establecido en las directivas conforme a los siguientes estándares Gama de No de Serie D Vose Patrick Livingston Nombre y firma de las personas autorizadas Nombre y firma de las personas autorizadas Fecha Fecha NOTA GUARDE ESTAS INSTRUCCIONES NO DESTRUYA Una vez vencida la vida útil de herramienta se recomienda desarmar la herramienta d...

Page 13: ...rovide the following information Model Number Part number as shown in parts list 3 13 11 1 2 10 14 17 12A 20 23 18 4 5 15 16 19 22 8 9 7 6 12 TP1897 21 24 1 Trigger Assembly PF150 A93 13 O ring 2 Trigger 14 O ring 3 O ring 15 Ring 4 Valve Body 16 Muffler Kit PF150 MK1 5 O ring 17 Bracket 6 O ring 18 Muffler 7 Valve Stem 19 Backing Plate Pack 2 PF150 825 8 O ring 20 Pad Nut PF150 226 9 Spring 21 Ho...

Page 14: ...14 ...