background image

e

hp

ocaGEO

 

2.0

8 - 10 On-Off

10 - 12 DC Inverter

12 DC Inverter ELEC 

User manual

EN

Summary of Contents for 10 HP DC

Page 1: ...ehpocaGEO 2 0 8 10 On Off 10 12 DC Inverter 12 DC Inverter ELEC User manual EN ...

Page 2: ...ages containing instructions or information for the user I Installer Refers to pages containing instructions or information for the installer S Service Refers to pages containing instructions or information for the CUSTOMER TECHNICAL ASSISTANCE SERVICE installer Editorial pictograms Safety pictograms Warning It indicates actions that require caution and a suitable preparation Prohibition Refers to...

Page 3: ... heat only modes 8 1 5 Brightness regulation 8 1 6 Touch screen display key lock 8 1 7 Hotel function 8 1 8 Heating operating only for ELEC model 8 1 9 Suggestions for power saving 9 1 10 Diagnosis of problems 9 1 11 Technical specifications 11 1 12 Periodic Maintenance 12 2 INNOVA App operation 2 1 Minimum system requirements 13 2 2 Installing and using the APP 13 General table of contents ...

Page 4: ... working but it does not dispense warm air to the room This phase can last from 3 up to maximum 10 minutes The appliance must not be installed in rooms where explosive gases develop or where there are humidity and temperature conditions that exceed the maximum levels reported on the installation manual Clean the air filter regularly as described in the specific paragraph Normally the display shows...

Page 5: ...t be inserted respecting polarity Once the battery is inserted close the cover In order to manage the appliance using the remote control and the touch screen the main switch on the electrical power supply line must be turned on its exact position can be indicated by the technician who installed the appliance or the power supply plug must be connected to the system socket Once such operations have ...

Page 6: ...se the speed of the fan Heating only mode In this mode the appliance heats the room Set on heating only mode the appliance periodically defrosts the evaporator coil if necessary During this phase the conditioner does not dispense warm air even if its internal components are on except for the room fan It is possible to set the desired temperature between 16 and 31 C and if such temperature is highe...

Page 7: ...nly in heating and cooling mode supplies a 30 minute Overboost Then the controller inhibits the function and switches to automatic mode By selecting Automatic mode shown by three speed bars moving up and down on the display the on board microprocessor automatically adjusts the speed so that it stays higher the greater the difference between the temperature detected and the temperature set This is ...

Page 8: ...EC has an additional electric element which provides heat when the weather conditions outside are bad The heat power of the resistor is equal to 1 000W so when the device software switches the 2 0 unit on it will provide the combined thermal power produced by the heat pump and the thermal power of the electric element If you need to operate the appliance in quiet mode it can be activated with elem...

Page 9: ...the operating logic of the unit so as to protect the compressor from frequent activations During operation in heating mode the warm air is delivered a few minutes after the activation of the compressor If the fan started at the same time as the compressor in the first minutes of operation the air delivered would be too cold which may disturb the occupants of the room since the unit is not yet read...

Page 10: ...nstructions below Cover large windows exposed to sunlight with curtains or with external maskings blinds porches reflecting films etc The air conditioned room must remain closed for as long as possible Avoid turning on halogen lamps or other high energy consumption appliances such as small ovens steam irons hot plates etc Alarm Cause Operation E1 Faulty room temperature RT sensor It is still possi...

Page 11: ...wer electrical element kW 1 00 Power in max heating mod Dual Power kW 2 64 3 05 3 05 Power absorbed when cooling 1 W 580 850 630 730 730 Power absorbed when heating 2 W 545 725 638 720 720 Dehumidification capacity L h 0 8 1 1 1 0 1 1 1 1 Power supply voltage V F Hz 230 1 50 230 1 50 230 1 50 230 1 50 230 1 50 EER W W 2 84 2 71 3 24 3 22 3 22 COP W W 3 12 3 1 3 29 3 28 3 28 Energy efficiency class...

Page 12: ...the concentration of impurities in the air or when you wish to start up the appliance after a period of inactivity The filter is located in the top part of the appliance To extract the filters open the grid and remove it extract the filters by lifting them remove the dust from the filter with a vacuum cleaner or by washing it in running water without using detergents or solvents and leave to dry p...

Page 13: ... only on Android devices If the automatic procedure does not start it can be configured manually as indicated below On the first screen it is possible to select the language preference and the way the push notifications are handled If you check the notification box the alarms will appear on your smartphone Figure 2 2 2 2 Installing and using the APP 1 From the application menu on your smartphone f...

Page 14: ...icate its serial number consisting of 9 alphanumeric characters as shown in the figure By entering the password the stand alone Innova2 0 network will be protected from unauthorised access N B for IOS devices after 2 0 label appliance the WiFi network will automatically change for find a network with Internet access So is necessary to edit another time the phone network settings and reconnect to t...

Page 15: ... 2 0 N B from now on you will have the possibility to control the air conditioner via the local WIFI network but not via Internet To do this it is necessary to take a further step and connect to the home office WIFI network by accessing the settings as in the figure on the right and selecting the option Remote Control Figure 2 10 Figure 2 13 Then enter the password of your WIFI network and confirm...

Page 16: ...0 Figure 2 15 At this point Innova 2 0 App will attempt to connect your unit to your home network thus smartphone air conditioner main screenshot for the management of the unit will appear again From now on your 2 0 is connected to the server trough Internet network and can be managed from all over the world via WIFI or your phone s data connection If the procedure fault smartphone tablet will aut...

Page 17: ...ay It is possible to program multiple on and off times with minimum intervals of thirty minutes in the same day If you want to repeat these periods in other days of the week it will be possible by following the instructions shown in the figures below Figure 2 22 Figure 2 23 Figure 2 24 Figure 2 25 Figure 2 26 ...

Page 18: ...ir conditioner will automatically scan all the 2 0 available on network Once your device found will be opened the 2 0 menu now you can cocontrol the 2 0 also with the second tablet amartphone To add new 2 0 select the menu key on the left of your screen my devices settings and click key that appear on top and right of your screen Now two lanels will appear find new devices manual add select find n...

Page 19: ...19 S I U EN NOTES ...

Page 20: ...ONO TN ITALY tel 39 0465 670104 fax 39 0465 674965 info innovaenergie com realized with iés technology by N273027A Rev 0 N273027C Rev 00 INNOVA s r l Via I Maggio 8 38089 STORO TN ITALY tel 39 0465 670104 fax 39 0465 674965 info innovaenergie com ...