Summary of Contents for GT4000

Page 1: ...ier s details and your postcode to hand before calling Replacements Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO __________________________ To claim your full 5 year warranty register your shower within 90 days of delivery at www insigniarange co uk...

Page 2: ...ical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing MK117 Control Panel Instructions Help Book Information Parts List 3 5 6 7 8 9 18 19 20 21 22 23 ...

Page 3: ...any years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK 1 Badge Very easy 2 Badges Easy 3 Badges Moderate 4 Badges Harder than average 5 Badges Professional skills requi...

Page 4: ... WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF A FULLY QUALIFIED ELECTRICAL COMPANY TO COMPLETE CONNECTION FROM SHOWER TO HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID REGARDS ELECTRICAL ITEMS IF THIS IS NOT UNDERTAKEN YOURS AND OTHERS SAFETY IS PARAMOUNT NEVER ATTEMPT THIS YOURSELF REMEMBER These showers are designed to be free standing and movable from the...

Page 5: ...two methods 1 Connect within current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version 2 Preferred Wire into isolated fused feed connecting directly to the house consumer service box Remove the fitted plug and ensure the Consumer unit has capabilities to replace RCD feature if RCD is removed Always use protection against electrical surge Your...

Page 6: ... use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the final fix What s In The Boxes Tray Box 1x Tray 1x Roof 2x Curved Rails Internal Accessories Screw Pack 2 x extension cables Glass Room 2x Door seals 2x Glass doors 2x fixed glass 2 x Magnetic...

Page 7: ...ment missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Description Quantity SP097 Door Handles 2 SP008 Door Wheels 8 ST20 20mm Screws 20 ST35 35mm Screws 10 ST14 14mm Screws 6 ST25 25mm Screws 10 SW9 Small Washers 20 DB6 Drill Piece 1 ST55 55mm Screws 9 Note In so...

Page 8: ...es Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that this product is free standing and is designed to be pulled away from the wall The water supply and waste require flexible pipes If you purchased the fitting kit with this shower you will have the required fittings Th...

Page 9: ...o ensure the correct sealing and alignment is carried out In the side of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is blanked yet should you have a steam version you need to gently drill this out as this item is for the steam generator drainage and will be connected in the instructions later Now please level the tray by...

Page 10: ...are handed and can only fit one way Now place your completed front frame on the front of the shower tray as per the image on the right IMPORTANT When fitting the top rail ensure the wires from the column lights are held against the back of the grey plastic clips poking out of the top The rail is designed to sandwich the wires between the front of the rail and the back of the grey clips Now attach ...

Page 11: ...at for the other side 1 2 1 Step 5 Now you have locked the two back panels in position align the back panels to the central column Once you are happy with the alignment apply silicone to the bottom of the centre column and screw all parts to gether using the ST20 screws and SW9 Washers as per the image Note you may have a clear seal which sandwiches between the column and backwall ensure this is c...

Page 12: ...lumn lights here ready to connect later if a small gap exists silicone seal later Step 7 Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass Once all wheels are fitted and on the rails you can adjust the wheels by turning the plastic bolt clockwise in...

Page 13: ...elf brackets and secure by tightening the grub screw situated on the bottom of the bracket Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories We recommend using a screwdriver on the smaller holes Back Backrest The back rest is...

Page 14: ...run clear silicone around the rear side of the probe to keep it securely in position Ozone o3 Unscrew the chrome pepper pot end and drop the white box upside down into the rear hole as shown in the image Now from the inside of the shower re attach the chrome pepper pot end and tighten Monsoon Head Attach the grey hose from your valve to the inner black tube using PTFE tape please note this only ne...

Page 15: ...er from the image Please refer to your outer chrome faceplate in side your Insignia shower as a reference point IF YOUR DIAL DOES NOT CORROSPOND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub scre...

Page 16: ... and 2 x black together and tighten securely in to the connection block 3 Locate the other end of the wire with the 2 connect ors on 1 x male and 1 x female and plug the female end up to the corresponding symbol found on the wire coming from the electric box 4 With the last remaining connector 1 x male con nect this up to the corresponding symbol which is found on the back lights of the centre col...

Page 17: ...nect the end with the single connection to the light on the roof of the shower as shown in the image 2 Locate the 2 other connections on the at the oppo site end and connect one end to the tray lights 3 With the last remaining connector connect this up to the lead supplied from the electric box represent ing a light bulb symbol ...

Page 18: ...lectric Box Steam Generator Connections Fan Speaker Ozone Light Light 2 Thermostatic Probe RJ11 Phone Connection Radio Aerial AUX Audio In Connection Phone Connection This feature if fitted has now been disabled Please do not connect as it will not work ...

Page 19: ...r shower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this opening Drain Connect the grey rubber hose from the steam generators drain opening to the nozzle on the shower waste as shown in the below image Steam Generator Connections ...

Page 20: ...ng around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal on the OUTSIDE Please remember where you see the water this may not be exactly where the leak is as it could have run around to a low point Never seal your inner fittings accessories inside unless y...

Page 21: ...please ensure you have switch off the Bluetooth to any current paired devices as only one connection can occur at any one time Note The device you are looking to pair is either INSIGNIA or SPR OUT Button 7 Down Arrow Channel select down manual search Button 8 TUN Switch Between manual auto radio searching Button 9 Up Arrow Channel select up manual search up Button 10 Alarm Activate Alarm Button 11...

Page 22: ...www insigniarange com Last Modified 07 10 2015 22 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx ...

Page 23: ...ck SP227 Standard shower head Sp166 Approximately 4 meters of U Style seals SP057 90 Degree Chrome Water Inlet for foot massager Part Code Part Description SP300 Waste hose SP301 White insulated pipe SP221 Drain Hose SP233 MK117 Steam Genera tor Electric box SP306 Magnetic door seals SP310 Rear door seals SP173 4 Port 3 Feed Thermo static valve External Items Parts List Part Code Part Description ...

Page 24: ...e used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All images are registered with ImageTraker Insignia is a registered trademark of Maclean International Ltd ...