Under Counter Chiller

Model: UCCH1000

INSTALLATION INFORMATION

& USER INSTRUCTIONS

Instanta Limited

Canning Road, Southport

Merseyside, PR9 7SN

Tel: 01704 501114

Fax: 01704 501115

Email: info@instanta.com

Website: www.instanta.com

Join us at:

www.facebook.com/instantaltd

@InstantaLtd

IB28a

The Professional’s Choice

Summary of Contents for UCCH1000

Page 1: ...FORMATION USER INSTRUCTIONS Instanta Limited Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 Email info instanta com Website www instanta com Join us at www facebook com instantaltd InstantaLtd IB28a The Professional s Choice ...

Page 2: ...sed space e g kitchen cupboard Flexible water inlet hose assembly c w water purification filter NOTE An alternative ventilation kit is available from Instanta Spares Part No UCC D1 for installations within an enclosed cupboard that don t have a void space see Scenario 2 below 3 IMPORTANT INFORMATION FOR INSTALLATION The Instanta UCCH1000 Dry Chiller is designed to be fitted underneath a counter to...

Page 3: ... base of cupboard Void at back of cupboard minimum of 50mm Use TEMPLATE B to mark the opening for the exhaust air in the back of the cupboard void FRONT VENT COVER PLATE leave in place if vent kit and ducting are used as in this diagram Remove if vent kit is not being used and unit is placed on a solid floor instead Warm air expelled to avoid it being circulated within the cupboard space Use TEMPL...

Page 4: ...being recirculated within the cupboard space and therefore fulfils installation requirements SCENARIO 3 Typical installation NOT enclosed In this scenario the under counter unit is located underneath a work surface but not enclosed by a cupboard VIEW FROM ABOVE WARM AIR EXPELLED to avoid it being circulated within the cupboard space FRONT VENT COVER Remove if unit is placed on a solid COLD AIR INL...

Page 5: ...e space at the back of the cupboard and a way for the warm air to escape a 50mm void between the panel and the wall should be sufficient 3 Identify the best location for the chiller water font and filter Plan the connection to a water mains supply routing of any tubes and location of components to ensure the installation is as unobtrusive as possible 4 It is also necessary to ensure that the air i...

Page 6: ... replace screw Then secure the bracket by driving the self tapping screw to the cabinet base g Cut the blue water feed tube to size if too long and push into the CHILLED WATER OUT coupling It is advisable to fit insulation to the tube between the font and the chiller unit h Plug electrical lead into socket on top of chiller unit marked FONT CONTROL Important The ventilation openings must align wit...

Page 7: ...hiller unit at the back To adjust pull valve adjuster upwards and turn clockwise to increase pressure flow rate and anti clockwise to reduce As a guide a small cup 180ml should take approximately 5 seconds to dispense NOTE If the flow rate is faster than this the water will pass through the cooling block too quickly and the drink may not be as cool as it should be 9 TECHNICAL SPECIFICATIONS Under ...