Features.

Programmable V or mA Outputs.

Rangeable from 2 to 6 Digital Inputs

Bi-Polar Digital Inputs.

Isolated Input to Output 1600V.

Low Cost.

Easy to Install.

Compact DIN Rail Mount Enclosure.

Reverse Polarity Protection.

Adjustable Span & Zero.

Description.

The TW-DA is designed primarily for low cost digital to analogue conversions for PLCs, controllers, etc. Digital inputs
are converted in binary to analogue V or mA outputs.

TW-DA Digital to
Analogue Converter.

Isolated Parallel Digital

Input to  Three Wire V or mA

Analogue Output Converter.

Quality Assurance Programme.

The modern technology and strict procedures of the ISO9001 Quality Assurance Programme applied during design,
development, production and final inspection grant the long term reliability of the instrument.

13.07-1

Ordering Information.

TW-DA-X

Standard Unit, 4 Digital Inputs, 4~20mA Output.

TW-DA-      -

Special Range Calibration.

      D   AO

Ordering Examples.

TW-DA-6-A

TW-DA; 6 Digital Inputs; 4~20mA Output.

TW-DA-2-D

TW-DA; 2 Digital Inputs; 0~10V Output.

S

T

U

P

N

I

S

T

U

P

T

U

O

s

t

u

p

n

I

l

a

t

i

g

i

D

f

O

r

e

b

m

u

N

D

t

u

p

u

O

e

u

g

o

l

a

n

A

O

A

I

/

D

2

2

A

m

0

2

~

4

A

I

/

D

3

3

A

m

0

2

~

0

B

I

/

D

4

4

V

0

1

~

2

C

I

/

D

5

5

V

0

1

~

0

D

I

/

D

6

6

TECHNOLOGY

& QUALITY

A

W

A

R

D

ISO9001

E

G

IS

TE

R

R E

D

M

ANU A T

U

R

E

R

C

F

Z495

Summary of Contents for TW-DA

Page 1: ...erter Quality Assurance Programme The modern technology and strict procedures of the ISO9001 Quality Assurance Programme applied during design development production and final inspection grant the long term reliability of the instrument 13 07 1 Ordering Information TW DA X Standard Unit 4 Digital Inputs 4 20mA Output TW DA Special Range Calibration D AO Ordering Examples TW DA 6 A TW DA 6 Digital ...

Page 2: ...nstitute guaranteed properties and is not intended to affirm the suitability of a product for a particular application Due to ongoing research and development designs specifications and documentation are subject to change without notification Regrettably omissions and exceptions cannot be completely ruled out No liability will be accepted for errors omissions or amendments to this specification Te...

Page 3: ... gives 64 output steps 1 59 per step Use B32 for MSB B1 for LSB MSB Most significant bit LSB Least significant bit Calibrating the TW DA to the Required Ranges Note To range the unit select the output range first 1 With no digital inputs active use the ZERO Pot to calibrate the 0 point Note When adjusting 0 10V or 0 20mA ensure you do not overwind the ZERO Pot A slight offset may be left Wind the ...

Page 4: ...l Standard Cables B5103ES is recommended 4 It is recommended that you do not ground current loops and use power supplies with ungrounded outputs 5 Lightning arrestors should be used when there is a danger from this source 6 Refer to diagrams for connection information COMMISSIONING 1 Once all the above conditions have been carried out and the wiring checked apply power to the TW DA loop and allow ...

Reviews: