background image

 

USER MANUAL 

EPRO RACK 1.1K-3.4K 

____________________________________________________________________________________________

 

(120217_ENG) Integra EPRO RACK 1.1K-3.4K

 

  

1

 

 

 

 

ENGLISH 

 
 

 
 
 

USER MANUAL 

EPRO-RACK 1.1K – 3.4KVA 

ONLINE DOUBLE CONVERSION UPS 

 

User Manual:  

 

220V (Europe: «Schuko» Zone) 

 

110V (America: «NEMA» Zone) 

 

 

 

 

 

 

 
 

 

 
 
 
 
 
 

 

USER MANUAL 

EPRO RACK 1.1K-3.4K 

____________________________________________________________________________________________

 

(120217_ENG) Integra EPRO RACK 1.1K-3.4K

 

  

2

 

DO NOT connect laser printers, scanners, or copiers to this UPS. 

High power devices may damage this UPS

 

 

1. SAFETY AND USE: 

 
WARNING

: This product has been designed to operate safely and reliably for years. Nevertheless, as it is an 

electrical device, it is required to read and understand this manual. Keep manuals as references for future consults. 

 
WARNING

: This product has been designed to be used indoors, protected of water, direct sun light and extreme 

temperatures. This device must not be used outdoors, close to moisture of heat sources.

 

 
WARNING

: Do not set objects on this UPS. Handle with care. Do not block UPS ventilation.

 

 

WARNING

: Make sure to connect this unit to proper power line according to selected model. The UPS Technical 

Specs sticker shows power rating information. DO NOT connect this UPS to any of its own power outlets. 

 
WARNING

: UPS must be installed following instruction from this manual. 

The manufacturer is not liable for any damage that might rise from misusing this unit or defective installation. 

 
WARNING

: Only computer related equipment can be connected to this UPS. DO NOT connect medical 

equipments, life support equipments, microwave ovens, vacuum cleaners, refrigerators, or any other appliance to 
this UPS. 

 
WARNING

: UPS must be checked, repaired and maintained by qualified personnel only. This product is locked by 

screws. 

 
WARNING – ELECTRIC SHOCK RISK

:  

Inside the UPS there are dangerous high voltages even when disconnected of power line, due to internal batteries 

 
WARNING:

 In case of emergency turn off the UPS pressing Power Button, unplug it and call technical support. 

 

 
 
 
 

 
Disposal 

We strongly recommend disposing this UPS according to regulations in your country to prevent 
possible environmental damages; besides some parts might be recycled. 

 
BATTERY WARNING

: DO NOT dispose batteries in fire as it might explode. DO NOT try to open 

batteries, there are dangerous liquids inside. 

Summary of Contents for EPRO-RACK 1.1KVA

Page 1: ...ntilation WARNING Make sure to connect this unit to proper power line according to selected model The UPS Technical Specs sticker shows power rating information DO NOT connect this UPS to any of its o...

Page 2: ...2003 An Uninterruptible Power Systems UPS Part 1 1 General and Safety Requirement for UPS use operator access areas EMC Directives EN62040 2 2006 An Uninterruptible Power Systems UPS Part 2 Electroma...

Page 3: ...OWER ON Keep selected during 2 seconds or longer b BEEP MUTE In battery mode Keep selected during 5 seconds or longer to Mute acoustic alarm beep Some alarms cannot be muted as Bypass Warning or ERROR...

Page 4: ..._______________________________________________________ 120217_ENG Integra EPRO RACK 1 1K 3 4K 8 3 2 RACK UPS INSTALLATION Rack UPS must be installed using L Shape type guides for supporting UPS weigh...

Page 5: ...models but they can also be connected at any moment to EX BATT supplied by INTEGRA Special cables to connect EX BATT to UPS are supplied inside the box of EX BATT USER MANUAL EPRO RACK 1 1K 3 4K _____...

Page 6: ...power from batteries There is no dead time transition time is ZERO ms related to switching from normal mode to battery mode since load is always powered from inverter This is main characteristic of an...

Page 7: ...charging level 0 25 26 50 51 75 y 76 100 Indicates battery failure Indicates low battery level Input Information Indicates input voltage input frequency and DC battery voltage Vac Input voltage Vdc b...

Page 8: ...ts To able or disable programmable outlets function 09 Programmable To configure timer value in minutes for programmable outlets USER MANUAL EPRO RACK 1 1K 3 4K _______________________________________...

Page 9: ...as selected BATTERY MODE When AC input source is out of range Ups goes to battery mode to supply output from taking energy from batteries USER MANUAL EPRO RACK 1 1K 3 4K ______________________________...

Page 10: ...selected properly Push ON button during 2 seconds or longer 1 beep s alarm is active and LCD shows Input Line and Neutral are swapped Rotate UPS plug at wall socket to allow correct line neutral conne...

Page 11: ...igurable scheduled shutdown and Auto tests Some UPS models include software CD inside the box Others allow software downloaded from our website www integra ups com 14 BATTERIES MAINTENANCE 14 1 BATTER...

Page 12: ...teries Kit 1 Remove batteries from plastic assembly 2 Connect new batteries in series as indicated below 3 Place batteries inside plastic assembly 4 Close battery assembly 5 Using a DVM check battery...

Page 13: ...al service caused by improper packing of the product by user 12 Warranty time could be extended to 3 years depending on market or products Contact your authorized dealer for additional information 13...