Thermal Imaging Camera

Manual

Summary of Contents for HT-02

Page 1: ...Thermal Imaging Camera Manual ...

Page 2: ... Based on practical requirements it can turn thermal image into visional image Thermal image and visional image can be stored in the dismountable memory card Adjust the images and store them in PC which are used to generate report or for printing HT 02 is easy to operate After seconds it can be tested This product is the optimum product for electrician and maintainer It can quickly find out the pr...

Page 3: ...age 60 60 3600 pixels Resolution of visible image 0 3 mega pixels Field angle shortest focal distance 20 20 0 5m Thermal sensitivity 0 15 C Range of temperature measurement 20 C to 300 C Accuracy of temperature measurement 2 or 2 C 2 or 4 Emissivity Adjustable 0 1 1 0 Image capturing frequency 6Hz Range of wave length 8 14um Focal distance Fixed focal distance Color palette Iron red rainbow rainbo...

Page 4: ... capturing key Interface for the installation of tripod 10 5 Structure 1 5 2 4 6 7 8 9 10 3 Figure 2 Structure of Product Description Time setting Save image Background light setting Temperature unit setting Background temperature setting Capacity of memory card Color palette setting Emissivity setting 6 Menu Description 12 12 5000 50 ºC 25ºC 11088MB 0 95 Icon Figure 3 Menu s Icons and Description...

Page 5: ...n Move the product until hot spot or cold spot coincides with the center of pixel Direct the product to the object whose temperature is higher or lower than the surrounding temperature to get the optimum measured results 9 Focal distance This product is the fixed focal thermal Imaging Camera The applicable distance is 50cm 20min Image storage 10 Elimination of noise Start up the instrument and the...

Page 6: ...y situations adjust the temperature of reflective background to get the optimum measured result 14 Marking of spot temperature Turn on or off the marking of spot temperature If turning on the marking of spot temperature indicates that the hot spot or cold spot in the screen needs additional appraisal If turning off it indicates that user can focus on the measured pixel per time 15 Unit of temperat...

Page 7: ...Press the MENU button to exit Review 20 Notes All the objects have the radiated infrared energy The radiated quantity of infrared energy is based on the actual temperature and radiation coefficient of surface Our instrument can sense the infrared energy on the surface of object and estimate the temperature based on the sensed value of infrared energy Many objects e g coated metal wood water skin a...