background image

Tuck wires into wall box(s) leaving room for the device(s).
Using screws provided, mount the switch timer into the wall 

box, then install the wall plate. 
Turn power back on at the service panel.

You are ready to set the DATE and TIME—Proceed to Section 3.

For 3-way Switch and Other Multiple Switch Setups:

NOTES: 

When installing the EJ500 switch timer in circuits with 

two or more switches:

The wiring is different when using the EJ500 switch timer 
than when using conventional toggle switches. Read the 
following installation instructions carefully.
The distance between switch timer and remote switches 
must not exceed 100 feet, and wiring to the remote switch-
es must not be buried underground.
Used remote switches from a previous conventional instal-
lation may not function reliably with an electronic timer. Try 
a brand new remote switch if function is intermittent.

For Existing 2-Switch (3-way) Installations:

Locate the COMMON wire 

connected to first old switch. 

It might be attached to a dif-

ferent colored screw, or find 

markings on old switch.
Connect BLACK wire from 

switch timer to COMMON 

wire, using a twist connector.
Connect the other two wires from the old switch to either the 

BLUE and RED wires from the switch timer.
Connect the ground wire from the box to the BARE COPPER 

wire on the switch timer. If there is no ground wire, ground the 

switch timer to the box. If the box is plastic, connect the bare 

copper wire to ground as supplied or contact an electrician.
Locate the COMMON on the second old switch of the 3-way pair.
Connect jumper wire (supplied) from the COMMON terminal 

to either of the other terminals on the remote 3-way switch.
Make sure all twist connectors are tight.
Tuck wires into wall boxes leaving room for the devices.
Mount the devices into the wall boxes, then install the wall plates. 
Turn power back on at the service panel.
Make sure the switch timer displays “MAN” mode. Do the fol-

lowing test with the remote switch in each of its 2 positions:

Press the 

NEXT ON/OFF

 button on the switch timer several 

times. Each time that you push the 

NEXT ON/OFF

 button, the 

switch controlled light or device (the “load”) should turn on 
or off. If so, proceed to Section 3.

If the timer display changes between ON and OFF but the 

load does not operate, re-check your wiring and make sure 

the load is functional.
If the timer display changes 

between ON and OFF but the  

load only operates when the 

remote switch is in one of 

its 2 positions, you need to 

turn off the power at the service panel, change the jumper 

wire to the other terminal. Then turn power back on at the 

service panel and repeat 

Step

 

11

You are ready to set the DATE and TIME—Proceed to Section 3.

c.
d.

e.

1.

2.

3.

4.

5.
6.

7.
8.
9.
10.
11.

-

-

Self-Adjusting Indoor 

          Wall Switch Timer

Turn off power at the service panel by REMOVING FUSE or 

TURNING THE CIRCUIT BREAKER OFF.
Remove the existing wall switch.
Trim building wires to 7/16” as shown.

For Single-Switch Installations:

Connect one of the two wires 

from the wall to the BLACK wire 

from the switch timer, using the 

twist connectors provided. 
Connect the other wire from 

the wall to the BLUE wire from 

the switch timer, using the twist 

connectors provided.
NOTE: 

The RED wire is not used in single-switch installations. 

Cap with a twist connector.

Connect the ground wire from the box to the BARE COPPER 

wire on the switch timer. If there is no ground wire, ground the 

switch timer to the box. If the box is plastic, connect the bare 

copper wire to ground as supplied or contact an electrician.
Make sure all twist connectors are tight.

1.

2.
3.

a.

b.

a.

b.

500W single gang or 2 gang installations (40W minimum)
4 Amp Tungsten (

incandescent

120 VAC, 60 Hz
Operating Temperature: 32°F (0°C) to 104°F (40°C)




Installation and User Instructions

MODEL EJ500

2 – Install the Switch Timer

Ratings

Before installing the switch timer into the wall, make sure the 

supplied batteries are installed and working. 

Open the access door to reveal the battery tray, located below 

the keypad.
Remove the tab to connect the installed batteries. Make sure 

battery tray is pushed fully into place.
The display will initialize itself then flash “12:00 AM” in 

MANual mode.

NOTE: 

If display doesn’t flash “12:00 am”, the battery may be 

dead. Replace the battery before installing the switch timer.

1.

2.

3.

1 – Before Installing Switch Timer, Install and Check Battery

BLACK WIRE

BLUE WIRE

RED WIRE

(capped, not connected)

RED WIRE

BLUE WIRE

BLACK WIRE

WIRE FROM

“COMMON” OF

OLD SWITCH

7/16”

158--00413

Observed Problem

Possible Cause

What to Do

Timer is blank until any button is pushed, 

and display changes between ON and OFF 

when pressing door, but light stays OFF.

Bulb is missing, loose, disconnected or burned 

out. 

Make sure bulb is good and that there are no 

other switches, photo controls, etc., in the circuit 

controlling the bulb. 

“Air Gap”switch at upper edge of timer is 

switched off.

Make sure “Air Gap”switch is in it’s ON position 

(slid to the left with slider in center of slot). 

No power (fuse or circuit breaker blown)

Make sure fuse is good or circuit breaker is on.

Timer does not switch but display is normal.

Timer not in AUTO, AUTO RAND(om), or 

MAN(ual) mode.

Press 

MODE

 to select the desired operating mode.

Timer works manually but does not follow 

scheduled program.

Timer not in AUTO or AUTO RAND(om) mode.

Press 

MODE

 to select AUTO or AUTO RAND.

Timer won’t enter the AUTO or AUTO RAND 

modes when MODE button is pushed.

Time of day and/or switching times are not pro-

grammed.

Make sure time of day and at least one scheduled 

activity are programmed.

Timer switches at incorrect times or skips 

some switching times.

Programmed schedule(s) are incorrect.

Review ALL 7 ON/OFF switching time pairs by re-

peatedly pushing 

NEXT/ON/OFF

 while in PGM mode 

and revise as necessary.

Timer is in AUTO RAND(om) mode (varies 

switching times up to ±15 minutes).

Press 

MODE

 to select AUTO mode.

When using a combination of Astronomic 

and Specific switching times, the timer 

switches at unexpected times or doesn’t 

switch when expected.

There are conflicting Astronomic and Specific 

switching time settings. Your timer automatically 

skips any conflicting ON EVENTS as summer 

approaches to prevent unwanted operation of 

lights. See the next column if you wish to identify 

and remove conflicting settings.

Complete the steps under “Setting the Calen-

dar.”
Temporarily change your timer’s calendar set-

ting to June 21st. 
Review the SUNUP and SNSET times by push-

ing the 

NEXT/ON/OFF

 button. 

Make sure your specific ON or OFF time set-

tings won’t interfere with these Astronomic 

switching times. 
Be sure to change the date back to today’s date 

when you’re done.

1.

2.

3.

4.

5.

Load state doesn’t match programmed state 

immediately after programming the time or 

schedule.

The timer does not “catch up” to the pro-

grammed load state. Instead, the load will remain 

in its current state prior to entering the PGM 

mode. The timer will then begin following the 

scheduled program at the next contrary ON/OFF 

time.

After entering your schedules or the time, then 

returning to the AUTO modes, push 

NEXT/ON/OFF

 

to change the load state if necessary.

Load only operates when the remote (3-way) 

switch is in one position or timer ignores the 

remote switch.

Remote switch is wired incorrectly.

Recheck wiring, especially for the jumper, per 

“2–Install the Switch Timer”.

Timer ignores remote (3-way) switch even 

though it is wired correctly.

Excessive length of wire (greater than 100 feet) or 

buried wiring to the remote switch.

Eliminate condition by replacing the buried cable 

or doing without the remote switch. Consult fac-

tory for other options.

Remote switch is defective or worn out.

Replace the remote switch.

Load turns off immediately after being 

turned on.

Remote switch or timer wired incorrectly, exces-

sive length of wire (greater than100’) or buried 

wiring to remote switch, or defective timer.

If the problem persists with the timer’s red wire 

disconnected or with a remote switch temporarily 

connected right at the timer, replace the defective 

timer. Otherwise try the above remedies.

Battery holder is difficult to snap in place.

Batteries not seated in holder, holder misaligned, 

or contact tabs of holder are bent.

Seat the batteries, then install the holder with the 

notch facing down.

Troubleshooting Guide

LIMITED ONE-YEAR WARRANTY

If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is 

extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent 

use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) 

sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installa-

tion costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL 

DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING 

THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL 

BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY 

NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage prepaid to the authorized 

service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675-7000 http://www.intermatic.com Please be sure to 

wrap the product securely to avoid shipping damage.

INTERMATIC INCORPORATED, SPRING GROVE, ILLINOIS 60081-9698

Electrical shock hazard. Risk of injury or death. Remove electrical power at 
service panel before installing.
Risk of fire and burns. Do not recharge, disassemble, heat above 212°F 
(100°C), crush, or incinerate the alkaline battery. Keep out of reach of 
children.
Risk of fire. Do not use timer to control devices that could have dangerous 
consequences due to inaccurate timing such as sun lamps, sauna, heaters, 
crock pots, etc.

          WARNING

Follow local electrical codes during installation.
Risk of timer damage due to leakage if weak battery is not replaced promptly.
Dispose of used battery promptly per local regulations.
Do not use with PAR or “R”-type outdoor flood lamps larger than 150 watts.
Do not use with mercury vapor lights, appliances, radios TVs, stereos, etc.
Do not use in combination with separate dimmers or photoelectric switches. 






NOTICE

COMMON

REMOTE

3-WAY

SWITCH

MOVE

JUMPER WIRE

TO OTHER

TERMINAL

IF THIS

SWITCH

DOES NOT

TURN LIGHT

ON