background image

Before Installing

1.

Check the parts in both packages against the Parts Lists shown above. Contact Intermatic if parts are missing. 

2.

It is suggested that you read these instructions completely before installing the Stand Alone Protection (SAP) unit. 

Note: These modules rely on a good ground connection to function properly. Ground availability

should be a consideration when selecting an installation location. 

Do not install Protection Devices during Electrical Storms.

I

NSTALLATION

I

NSTRUCTIONS

Telephone Indoor Stand Alone Protection 

Flush Installation  

Model Numbers:

Description:

IG2TM

2-line telephone protector with indoor enclosure (NEMA 1) 

IG4TM

4-line telephone protector with indoor enclosure (NEMA 1) 

Optional Modules
IG2T

2-phone line protection module 

Models

SURGE PROTECTION

Description

Quantity

Reference

Mounting Frame

1

A

Cover / Back plate

1

IG2T (in Model IG2TM)

1

IG2T (2nd module in Model IG4TM)

1

D

Screws-self threading (3/8” Torx T20 / slot head)

2

Ground Wire 

1

F

3/4” x 6 Pan Head Screws  (

not shown

)

4

3/4” anchors   (

not shown

)

4

Description

Quantity

Reference

Flush Mount Cover Plate

1

Mounting Bracket

1

Screws-self threading (3/8” Torx T20 / slot head)

4

K (Fig.4) 

Screws-self threading (5/8” Torx T20 / slot head)

2

L

3/4” x 6 Pan Head Screws  (

not shown

)

4

Parts List

Additional Parts
Flush Mount Kit

A

A

C

D

H

J

F

E

E

B

B

Flat head screw driver, Torx head
screw driver, Awl or hole punch, drill,
1/8” and 3/16” bits.

Tools Required

Notes:

1. Telephone protection is compatible with 
Voice and Fax lines, Modem lines and 
DSL (Digital Subscriber Lines.) 

2. Coaxial protection is compatible with 
Local antenna, Cable/Satellite and 

Cable Internet lines.

Figure 2

Figure 1

L

Summary of Contents for IG2TM

Page 1: ...phone line protection module Models SURGE PROTECTION Description Quantity Reference Mounting Frame 1 A Cover Back plate 1 B IG2T in Model IG2TM 1 C IG2T 2nd module in Model IG4TM 1 D Screws self threading 3 8 Torx T20 slot head 2 E Ground Wire 1 F 3 4 x 6 Pan Head Screws not shown 4 3 4 anchors not shown 4 Description Quantity Reference Flush Mount Cover Plate 1 H Mounting Bracket 1 J Screws self ...

Page 2: ...s properly connected to the building ground Use at least 12 gauge wire if additional length is required A5 Allow approximately four inches 4 of phone cable for each connection set Leave enough slack in the cable to allow it to be secured to the Mounting Frame without placing stress on the wires and terminals Route the incom ing phone cable unprotected to the top of the unit note the IN on the phon...

Page 3: ...aution when removing the jacket to prevent nicking the individual wires B7 Identify the pairs of wires to be protected and strip one quarter inch 1 4 of insulation from each wire in both the IN and OUT phone wires Exercise caution when removing the insulation to prevent nicking the individual wires B8 Insert the first pair of wires into the first two positions in terminal strip marked CN1 located ...

Page 4: ... 16 CUT OUT AREA INSIDE OF DASHED LINE FLUSH MOUNT COVER PLATE Model Number IGFLUSH ordered separately INSTALLATION NOTES This plate may be installed in the Vertical or Horizontal position Position this template over the surface and mark the cut out area through the template Carefully cut out the marked area CUTTING TEMPLATE ...

Reviews: