3-Way Switch Setup
NOTE:
The distance between switch timer and remote switch must
not exceed 100 feet.
1. Locate the COMMON wire connected to fi rst old switch. It might
be attached to a different colored screw, or fi nd markings on old
switch.
2. Connect BLACK wire from switch timer to
COMMON wire, using a twist connector.
3. Connect the other two wires from the old
switch to the blue and re wires from the timer.
4. Connect green wire to grounding screw in the box.
If plastic box, connect to ground.
5. Remove wire “C” from the “Common” terminal of
the existing remote switch.
6. Reconnect wires “B” and “C” to the common termi-
nal of your remote switch, using the supplied piece
of jumper
wire. If using a new single-pole remote
switch. See diagram 3.
NOTE:
For new construction or replacing a dimmer switch, a lighted switch, or a 3-way
switch without screw terminals, a single-pole switch can be used at the remote location. If
unable to determine the proper wire colors, choose one of the wires and connect as wire B.
After the installation is complete, if the controlled light or device will not turn on properly,
reverse wires “A” and “B”. See Steps 11 and 12 for how to check.
7. Tuck wires into the timer wall box leaving room for the timer.
8. Using screws provided, mount the switch timer into the wall box, and install wall plate.
9. Install the remote 3-way switch in its box and install wall plate. Turn power ON.
10. Make sure
MAN
mode appears.
11. Press
ON/OFF
button on the switch timer several times. Each time you push the
ON/
OFF
button, the switch timer should ‘“click” and the controlled light or device (the “load”)
should turn on or off. If so, proceed to Step12
.
- If timer clicks but load does activate, check wiring and make sure load is functional.
-
If the timer clicks but the load only operates when the remote switch is in one of its
2 positions, you need to turn off the power at the service panel, then reverse wires
“A” and “B”. You can reverse wires “A” and “B” at the remote switch wall box, or you
can reverse wires “A” and “B” where they connect to the red and blue wires of the
switch timer. Then turn power back on at the service panel and repeat Step 11.
12
.
Verify the controlled load turns on or off each time the remote switch is operated.
Multiple Time Switch Setup
Multiswitch applications using the ST01 timer are wired differently than conventional
toggle switches. Read the following installatin instructions carefully.
•
Multiple timers may be mounted in an unlimited number of adjacent junction box slots
•
No derating is required for multiple switch timers.
BLACK WIRE
BLUE WIRE
RED WIRE
(capped, not connected)
RED WIRE
BLUE WIRE
BLACK WIRE
WIRE FROM
“COMMON” OF
OLD SWITCH
DIAGRAM 1:
TYPICAL
EXISTING
2-SWITCH
SETUP
LOAD
NEUTRAL
3-WAY
MAIN SWITCH
WIRE “A”
“COMMON” TERMINAL
LINE
3-WAY
REMOTE SWITCH
WIRE “B”
WIRE “C”
DIAGRAM 2:
2-SWITCH SETUP,
TIMER INSTALL
RE-USING EXISTING
REMOTE 3-WAY SWITCH
LOAD
NEUTRAL
WIRE “A”
“COMMON” TERMINAL
LINE
3-WAY
REMOTE SWITCH
WIRE “B”
NOT USED
BLACK
TIMER
BLUE
RED
WIRE “C”
JUMPER
DIAGRAM 3:
2-SWITCH SETUP,
TIMER INSTALL USING
NEW SINGLE-POLE
REMOTE SWITCH
LOAD
NEUTRAL
WIRE “A”
LINE
SINGLE-POLE REMOTE SWITCH
WIRE “B”
BLACK
TIMER
BLUE
RED
WIRE “C”
JUMPER
Installing the Battery
1. Open the access door to locate the battery tray, located below the ON/OFF keypad.
2. If there is a pull tab at the battery tray, remove the tab to connect the installed
battery.
3. Make sure battery tray is pushed fully into place.
4. Place the supplied “CR2” battery into the tray, obs and - markings on tray.
5. Replace the battery tray into the switch timer.
6. The display will initialize itself then fl ash “12:00AM” in
MAN
ual mode.
7. Press the
ON/OFF
button. The switch timer should “click”
Clearing the Timer
1. Press and hold down the
ON/OFF
button.
2. Using a paper clip or pen, press and release the
RESET
button.
3. When
INIT
appears on the screen, release
ON/OFF
. The screen displays 12:00 am.
Setting the Time and Date
1. Press
MODE
to display
SETUP
. and
then press
ON/OFF
.
2. Press
+
or
-
to set the current hour. and
then press
ON/OFF
.
3. Press
+
or
-
to set the current minute
and then press
ON/OFF
.
4. Press
+
to advance the year if needed.
- Press
ON/OFF
.
5. Press
+
or
-
to change the month. - Press
ON/OFF.
6. Press
+
or
-
to change the date and then press
ON/OFF
.
7. Press
ON/OFF
to choose
DST
(Daylight Saving Time)
•
Press
+
to select
Man
if you do not observe DST, or
•
Press
+
again to select
Auto
to automatically set for DST.
8. Press
ON/OFF
to choose zone.
9. Press
+
to select your zone. See Fig10.
10. Press
ON/OFF
to review Dawn Time.
11. Press
ON/OFF
twice to review Dusk Time.
12. Press
ON/OFF
twice to save.
Programming Dusk ON/Dawn Off
1. Press
MODE
to display
PGM
.
2. Press
ON/OFF
to scroll to
DUSK
.
3. Press
ON/OF
F to choose the days you need, then press
+
to change days from
ALL, M-F,
WeeKenD
, or individual day.
4. Press
ON/OFF
to SAVE your work. - Press
+
to go to Program 2.
5. Press
ON/OFF
twice to display
DAWN
.
6. Press
ON/OFF
to choose the days you need, then press
+
to change days from
ALL, M-F,
WeeKenD
, or individual day.
7. Press
ON/OFF
to SAVE your work. - Press
MODE
to display
AUTO
.
Programming Dusk ON/Fixed Time OFF
1. Press
MODE
to display
PGM
. - Press
ON/OFF
three times to choose
DUSK
.
2. Press
ON/OFF
to choose the days you need, then press
+
to change days from
ALL, M-F, WeeKenD
, or individual day.
3. Press
ON/OFF
to SAVE your work.
4. Press
+
to go to Program 2. - Press
ON/OFF
twice to display
DAWN
.
5. Press
+
until you get to 12:00 pm. - Press
ON/OFF
.
6. Press
+
or
-
to set the hour of the
OFF
time. - Press
ON/OFF
.
7. Press
+
or
-
to set the minutes of the
OFF
time.
8. Press
ON/OFF
to choose the days you need, then press
+
to change days from
ALL, M-F, WeeKenD,
or individual day.
9. Press
ON/OFF
to SAVE your work. - Press
MODE
to display
AUTO
.
Programming Fixed Time ON/Fixed Time OFF
1. Press
MODE
to display
PGM
. - Press
ON/OFF
button three times to choose
DUSK
.
2. Press
+
to change it to 12:00 pm. - Press
ON/OFF
.
3. Press
+
or
-
to set the hour for the
ON
time. - Press
ON/OFF
.
4. Press
+
or
-
to set the minutes.
5. Press
ON/OFF
to choose the days you need, then press
+
to change days from
ALL, M-F, WeeKenD
, or individual day.
6. Press
ON/OFF
to SAVE and then press
+
to go to Program 2.
7. Press
ON/OFF
twice to display
Dawn
.
8. Press
+
to change it to 12:00 pm. - Press
ON/OFF
.
9. Press
+
or
-
to set the hour for the
OFF
time. - Press
ON/OFF
.
10. Press
+
or
-
to set the minutes.
11. Press
ON/OFF
to choose the days you need, then press
+
to change days from
ALL,
M-F, WeeKenD,
or individual day.
12. Press
ON/OFF
to SAVE your work. - Press
MODE
button to display
AUTO
.
Installing the switch timer
1. Turn off power at the service panel.
2. Remove the existing wall switch.
3. Trim building wires to 7/16” as shown.
Single Switch Setup
1. Connect one of the two wires from the wall to the black wire from the switch timer, using
the twist connectors provided.
2. Connect the other wire from the wall to the blue wire from the switch timer, using the
twist connectors provided.
NOTE: The RED wire is not used in single-switch installations. Cap with a twist connector.
3. Connect the GREEN wire to the grounding screw in the box. If a plastic box, connect to
ground as supplied.
4. Make sure all twist connectors are tight.
Fig. 8
Fig. 10
South
North
Center
North
Center
South
IN-Wall Timer with Astro Feature
Installation and User Instructions
MODEL ST01K SERIES
• Resistive (heater) 15 A, 120-277 VAC
• Tungsten (incandescent) 15 A, 120 VAC, 6 A, 208-277 VAC
• Ballast (fl uorescent) 8 A, 120 VAC, 4 A, 208-277 VAC
• Motors 1 H.P. @ 120 VAC, 2 H.P. @ 240 VAC
• DC Loads 4 A, 12 VDC, 2 A, 28 VDC
Ratings
For a 3-Switch Setup follow the diagram below.
NOTE:
The remote switch(es) may not function when the accumulated wire length to the
remote switch(es) exceeds 100 feet or the wiring to the remote switch(es) is buried under-
ground. Contact Intermatic customer service for further information.
NOTE:
Remote switches from a previous conventional installation may not function reliably
with an electronic timer. Try a new remote switch if function is intermittent.
ADDITIONAL WIRE
LOAD
NEUTRAL
TWO 3-WAY SWITCHES
RED
BLUE
TIMER
BLACK
LINE
LIMITED ONE-YEAR WARRANTY
If within the warranty period specifi ed, this product fails due to a defect in material or workmanship,
Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended
to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage
to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which
have been subject to unauthorized repair, opened, taken apart or otherwise modifi ed; (c) units not used in
accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp
bulbs, LED’s and batteries; (f) the fi nish on any portion of the product, such as surface and/or weathering,
as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or
reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN
LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE
WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,
ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE
OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW
LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT
APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit
was purchased or (b) completing a warranty claim online at www.intermatic.com.
This warranty is made by: Intermatic Incorporated, Customer Service 7777 Winn Rd., Spring Grove,
Illinois 60081-9698. For warranty service go to: http://www.Intermatic.com or call 815-675-7000.
7/16”
Four or more switch setups
Use the preceding 3-switch installation diagram and connect 4-way switch wires between the
two 3-way switches.
•
Disconnect power at the circuit breaker(s) or disconnect switch(es) before
installing or servicing.
•
Installation and/or wiring must be in accordance with national and local
electrical code requirements.
•
Use COPPER conductors ONLY.
•
Do Not recharge, disassemble, heat above 212° F (100° C), crush, or incinerate
the non-replaceable Lithium battery. Keep Out of Reach of Children. Replace
only with Panasonic type CR2 or equivalent CR2 battery approved by
Underwriter’s Laboratories (UL). Use of a different battery may present a risk of
fi re or explosion upon disposal of battery.
•
Do NOT use timer to control devices that could have dangerous consequences
due to inaccurate timing, such as: sun lamps, saunas, heaters, crock pots, etc.
•
Risk of timer damage due to leakage if weak battery is not replaced promptly.
•
Dispose of product per local regulations for disposal of Lithium batteries.
WARNING
Risk of Fire or Electric Shock
NOTICE