background image

Specifications subject to change without notice.

441 02 7000 02 Dec. 2013

Owner’s Manual

INDUCED COMBUSTION GAS FURNACE

NOTE TO INSTALLER:
THIS MANUAL MUST BE LEFT WITH THE
EQUIPMENT USER.
USER: PLEASE READ ALL INSTRUCTIONS
IN THE MANUAL AND RETAIN ALL
MANUALS FOR FUTURE REFERENCE.

FIRE OR EXPLOSION HAZARD

Failure to follow warnings could result in injury, death, or

property damage.
Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any

phone in your building.

Leave the building immediately.

Immediately  call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire

  department.
Installation and service must be performed by a qualified

installer, service agency or the gas supplier.

!

WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury

and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Install a

carbon monoxide alarm in your home, even if you do not

own a gas appliance. Locate the carbon monoxide alarm in

the living area of your home and away from gas appliances

and doorways to attached garages. Follow the alarm

manufacturer’s instruction included with the alarm.

!

WARNING

Illustrations and photographs are only representative.

Some product models may vary.

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury,

death, or property damage.
Do not use this furnace if any part has been under water. A

flood

damaged furnace is extremely dangerous. Attempts to

use the furnace can result in fire or explosion. A qualified

service agency should be contacted to inspect the furnace and

to replace all gas controls, control system parts, electrical parts

that have been wet or the furnace if deemed necessary.

!

WARNING

Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification  of certification for individual products,
go to www.ahridirectory.org .

Summary of Contents for 441 02 7000 02

Page 1: ...ZARD Failure to follow this warning could result in personal injury and or death Carbon Monoxide is invisible odorless and toxic Install a carbon monoxide alarm in your home even if you do not own a g...

Page 2: ...S MANIFOLD GAS BURNER BLOWER DOOR SAFETY SWITCH BLOWER AND MOTOR CONTROL RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR HOT SURFACE IGNITER MANUAL RESET LIMIT SWITCHES GAS VALVE FLUE COLLECTOR BOX PRES...

Page 3: ...e chimney vent connector are clear and free of obstructions 2 The vent connector is in place slopes upward and is physically sound without holes or excessive corrosion 3 The return air duct connection...

Page 4: ...02266 Fig 7 Control Switch to OFF 6 After waiting 5 minutes if you still smell gas STOP Follow the safety information on the cover of this manual If you do not smell gas go to the next step 7 Turn the...

Page 5: ...F position See Fig 7 6 Replace the outer furnace door See Fig 9 7 If the furnace is being shut down because of a malfunction call your dealer as soon as possible PERFORMING ROUTINE MAINTENANCE With pr...

Page 6: ...llow this caution may result in personal injury Failure to follow this warning could result in personal injury or death For proper and safe operation the furnace needs air for combustion and ventilati...

Page 7: ...Check the manual reset limit switches located on the ends of the burner enclosure see Fig 1 and 2 If the furnace has experienced a high temperature condition due to inadequate combustion air these sw...

Page 8: ...ce technician to assure your inspection includes the following at a minimum DESCRIPTION INSPECTION INTERVAL Monthly Semi annually Annually Furnace specific external items Clean or replace air filters...