background image

INST

ALLER

GUIDE

Security Floodlight

E-636
E-638

IQ Europe Limited 

Sandbeck Lane, Wetherby LS22 7TW.

Visit us at www.iq-europe.co.uk 

Installation helpline 0871 717 1100

V1.0 - 04/05

IQ-OEMCTV200-150-GR
IQ-OEMCTV200-500-GR

SF-OEMCTV200-150&500-GR.qxd  16/05/2005  11:21  Page 1

Summary of Contents for E-636

Page 1: ...oodlight E 636 E 638 IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 V1 0 04 05 IQ OEMCTV200 150 GR IQ OEMCTV200 500 GR SF OEMCTV200 150 500 GR qxd 16 05 2005 11 21 Page 1 ...

Page 2: ...ation ON CONDITION THAT The buyer takes advantage of any return to store scheme operated by the seller from whom it is bought If the product has a defect outside the period of any seller s return to store scheme it should be returned to IQ Europe Limited at Sandbeck Lane Wetherby W Yorks LS22 7TW England at the expense of the buyer together with evidence of the date of purchase it is the responsib...

Page 3: ...or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful positioning of the sensor will be required to ensu...

Page 4: ...ated onto the wall plate by two lugs which are inserted into the rectangular slots in the top of the wallplate To remove loosen but do not remove the fixing screw and lift the body of the floodlight upwards to release from the wall plate diagram F Mark the position of the fixing holes Ensure wall plate is correctly positioned Note the orientation of the wall plate diagram E Drill the holes Insert ...

Page 5: ...ve Restrict RHS detection Restrict LHS detection Restrict long detection Restrict short detection Lens Mask Less sensitive 12m TOP VIEW SIDE VIEW 2 5m A 200º Dusk Time SF OEMCTV200 150 500 GR qxd 16 05 2005 11 21 Page 5 ...

Page 6: ...E G UP F H wall plate fixing screw SF OEMCTV200 150 500 GR qxd 16 05 2005 11 21 Page 6 ...

Page 7: ...light to the wall plate by locating the lugs onto into the recess on the top of the wall bracket lift the floodlight so it fits over the wall plate reverse diagram F Fully tighten the fixing screw fig E Mains Supply Isolation Switch The diagram below also shows the required connections for the addition of slave luminaires When adding slaves be sure not to exceed the maximum switchable load see Tec...

Page 8: ...peration The TIME setting controls how long the unit remains illuminated following activation after all motion ceases The minimum time fully anti clockwise is approx 5 seconds whilst the maximum time fully clockwise is approx 5 minutes Set the control to the desired setting between these limits The DUSK control determines the level of darkness required for the unit to start operating The setting i...

Page 9: ...e before resuming normal PIR operation Halogen Lamp Replacement CAUTION Always handle quartz halogen bulbs with a soft cloth Do not touch the bulb with your bare hand as it will shorten the life of the bulb 1 Switch off the floodlight Do not touch the Floodlight while it is in use or still hot Allow it to cool about 5 minutes before touching it 2 Replacement bulb type is 240V mains halogen 150W or...

Page 10: ...ill not detect through glass The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details Adjust the setting anti clockwise to lower the level of ambient light required for activation Unit may be poorly located See pr...

Page 11: ... to 40 in running costs whilst also conserving precious natural resources LIGHT POLLUTION CONSIDERATE LIGHTING Please be aware of the annoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light sprea...