background image

A l l e r g e n 10 0

HyperHEPA® High-Performance Air Cleaning System

for Advanced Airborne Particle Control

User’s Manual

HB A100 GB_0407 / 105 10 31 12

Swiss Made

Summary of Contents for Allergen 100

Page 1: ...Allergen 100 HyperHEPA High Performance Air Cleaning System for Advanced Airborne Particle Control User s Manual HB A100 GB_0407 105 10 31 12 Swiss Made ...

Page 2: ... appliances Only use this appliance for its intended purpose of air cleaning in non industrial environments Do not use this appliance in areas with very high concentrations of dusts or powder to prevent the danger of dust explosions Do not use this appliance in explosive areas Only use filters and accessories recommended by IQAir Do not use outdoors Do not obstruct the air inlet and air outlet of ...

Page 3: ...etting the Daily Timer 15 4 4 4 Setting the Weekly Timer 16 4 4 5 Timer ON OFF Fan Speed Selection 16 4 4 6 Timer Information in the Control Panel 17 4 4 7 Time Day Setting 17 4 4 8 Filter Life Reset 18 4 4 9 Changing Airflow Units 18 4 4 10 Language Setting 18 4 4 11 Filter Load Index Setting 19 4 4 11 1 Determining the Filter Load Index 19 4 4 11 2 Modifying the Filter Load Index 20 Chapter 5 Us...

Page 4: ...ollutants enter the room air is high or the indoor air quality requirements are stringent the hourly air delivery of the system needs to exceed the room air volume several times To achieve that level of air turnover it may be necessary to employ more than one system Air Cleaning Results Although air cleaners may be advertised and sold to be suitable for use in specific indoor environments and to d...

Page 5: ...n sein sollte kontaktieren Sie uns unter info incen com oder der Faxnummer 41 71 844 0845 Um eine reibungslose Bearbeitung Ihrer Service Anfrage zu gewährleisten halten Sie bitte folgende Angaben bereit Modellname Artikel und Seriennummer diese Angaben befinden sich auf dem Serienschild auf der Systemunterseite Ihre Angaben Name Adresse Telefonnummer E Mail Kaufdatum Problembeschreibung Bestellung...

Page 6: ...4 5 6 Turn the device upside down on a soft and clean surface Place the mounting rail on the purifier s base so that the holes line up with the black connector pins on the base The cut ins should face the center of the unit Press down until the mounting rail snaps into place Repeat with second rail Place the caster onto caster pin Press on caster until it snaps into place Repeat steps 4 and 5 with...

Page 7: ... a wall or a cupboard In general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cable is positioned in a way that it does not present an obstacle that could be tripped over Make sure that the system is positioned in such a way that the control panel is easily accessible 2 4 Connecting to Power 1 Plug t...

Page 8: ...gn features air intake openings on two sides The PreMaxTM filter module consists of frame 1 and the PreMaxTM filter which is fixed inside the frame by four filter clamps The fan assembly comprises two housing modules with the centrifugal fan inside The HyperHEPA filter module consists of frame 2 and the HyperHEPA filter The EvenFlow diffuser features the omni directional air outlet openings The ha...

Page 9: ...eral square meters of tightly pleated HyperHEPA filter media that removes even the tiniest particles 5 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Description of Removable Components The IQAir system features a modular housing design which enables the easy replacement of all filters in a matter of seconds The illustration below shows all the removable comp...

Page 10: ...f the front locking arm Several operations can be completed via the electronic control panel including Switching the system on and off Controlling the fan speed and corresponding air delivery rate Checking the remaining filter life of the individual filters Setting the automatic timer Resetting the Filter Life Monitor after replacing a filter Locking the control panel to avoid tampering with the s...

Page 11: ...atically either due to a reduction in airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through the frequency of their rotation The faster the rotation of the fan speed LEDs the faster the actual fan speed of the unit 4 2 Control Panel Locking Function The control panel can be locked to avoid tamp...

Page 12: ...an IQAir system in a specific environment are calculated as follows hourly air delivery of the IQAir system m3 h air changes per hour ACH air volume of the room m3 N B The air delivery rates at the various fan speeds settings are listed on the Technical Specifications sheet Example calculation A room with the dimensions of 4x 4 x 2 6 meters has an air volume of 41 6m3 With an air delivery rate of ...

Page 13: ...mpared with an internal memory bank which contains infor mation about the different filters lives under specific conditions of use The Filter Life Monitor makes a calculation of the remaining filter life taking into account not only past use of the system but also likely future use As reference for future use the filter life monitor uses the fan speed and the filter load indices which are programm...

Page 14: ...ain display window press the Menu key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the key once to activate the timer Note If the start and stop time are identical the timer cannot be activated 4 Press the Enter key to save the timer status setting and to proceed to the start time 5 Select the desired start hour by pressing the key 6 Press the Enter key to save the...

Page 15: ...tion exits the enter mode 4 4 4 Setting the Weekly Timer The weekly timer allows the activation deactivation of the Timer ON period on certain days of the week In its default setting the timer is enabled on all seven days of the week This is indicated by stars below the abbreviations of the days On days without a star the air cleaner will be running at the speed which is set in the Timer OFF Fan S...

Page 16: ...s and hold the Enter key until the cursor starts to flash 3 Select the hour by pressing the key 4 Press the Enter key to save the hour setting and to proceed to the minute setting 5 Select the minutes by pressing the key 6 Press the Enter key to save the minute setting and to proceed to the day setting 7 Select the day of the week by pressing the key 8 Press the Enter key to save the day setting a...

Page 17: ...play window press the Menu key eight times The current display language is displayed 2 To change the display language press and hold the Enter key until the cursor starts to flash 3 Use the key to scroll through the display language options 4 Press the Enter key to save the desired display language and to exit the enter mode 18 Chapter 4 Using the Control Panel 4 4 9 Changing the Airflow Units N B...

Page 18: ... will remain airborne for long periods of time This dust group is made up of small combustion particles that are created as the result of combustion processes of automobiles small allergen particles such as cat allergens tobacco smoke particles etc 4 4 11 1 Determining the Filter Load Index The setting for each of the filter load indices can range from very low to very high The system is supplied ...

Page 19: ...to the Fine Dust index 6 Press and hold the Enter key until the cursor appears 7 Press the key to modify the Fine Dust index to reflect the fine dust pollution levels found in the environment where the system is used for guidance see previous section 8 Press the Enter key to save the Fine Dust index setting 20 Chapter 4 Using the Control Panel Limitations of Filter Load Indices The concept of filt...

Page 20: ...is possible to switch the timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch the timer off press the Timer Modification key and then the Timer OFF key 5 2 Getting the Best Transmission Results The IR infrared receiver of the IQAir system is positioned underneath the control panel cover In order to get the best signal...

Page 21: ...atter of minutes The illustration of the IQAir system on the right side of the control panel shows the positions of the individual filters These positions correspond to the actual positions of the filters within the system 6 2 Ordering Replacement Filters Please order the replacement filter elements from your point of purchase by quoting the name and the article number of the filter Both can be fo...

Page 22: ...elease the arm from its snap in position in the diffuser Disengage the other arm in the same way 3 Pull both locking arms evenly outwards until they snap into place and remain open Access to all filter elements is now possible to change a specific filter refer to the appropriate section below 4 To close the housing simply push the locking arms inwards simultaneously until they snap back into the h...

Page 23: ...e back into the housing For details on how to close the housing please refer to the section 6 3 8 Dispose of the used filter by placing it into the plastic bag in which the new filter is supplied 7 Lift the frame from the filter 10 Make sure that the filter is inserted all the way into the frame Insert the clamps into the sliding grooves inside the frame and push them down If harmful substances ar...

Page 24: ...he new filter is supplied see the section 6 7 9 Put frame 2 back into the housing and reposition the diffuser For closing refer to the section 6 3 Frame 2 6 6 Discarding Used Filters Used filters can normally be put into the regular household trash for disposal If the system may have been exposed to potentially hazardous substances the filters may have to be disposed of as hazardous waste Please r...

Page 25: ...for the secure wall mounting of the IQAir system where floor space is limited InFlow Complete ducting adapter kit for the creation of positive pressure if placed within the room and negative pressure if placed outside the room OutFlow Complete ducting adapter kit for the creation of negative pressure if placed within the room and positive pressure if placed outside the room FlexVac Mobile floor ba...

Page 26: ...INCEN AG Blumenfeldstrasse 15 CH 9403 Goldach Switzerland Tel 41 71 844 0844 Fax 41 71 844 0845 email info incen com www iqair com ...

Reviews: