The IRROmesh System is

a wireless mesh network

data collection system that

automatically records soil

moisture and other sensor data.

This data can be viewed in real time on the WEB or
downloaded in the field. Manually collected data can
also be uploaded to the WEB. This manual provides
detailed instructions for setup and installation.

Planning Your Network Layout

Plan the network layout ahead of time, before

installing any hardware. Determine the areas needed
to monitor soil moisture. Careful selection of mesh
radio Node locations is also critical to establishing good
communication of data. Consequently, there is a dual
requirement of “where the Sensors should be located”
and “where the Nodes should be located.” Determine
the best layout to satisfy both requirements.

Map out your field and indicate all areas that require

monitoring, then identify possible Node locations that
correspond to each area being monitored. Determine if
the range and placement of Nodes will establish a
good communication network. It may be necessary to
add Nodes, with or without sensors, to relay the data
transmission in acceptable path lengths and offset
angles. Mapping out the potential Node/Sensor
locations to verify that distances are acceptable and
potential obstructions are avoided will make the
physical deployment of the hardware much easier.

Avoid installation near areas with potentially strong

radio signal interference. Areas such as airports, cell
towers, etc. can pose significant interference. 

For best communication:

A

– The Base Node should be located near the

network’s center. Install the Base higher than the Nodes
reporting directly to it. 

(see Figure 1)

B

– Relay/End Nodes, should be at least 10 ft

(3m) above ground and a minimum of 5 ft (1.5m)
above the mature crop canopy to ensure clear-
line-of-sight (CLoS). 

(see Figure 1) 

The ideal radio

wave pathway is not simply a single straight line
between two points, but rather, a three
dimensional oval-shaped zone. Anything that
protrudes into this zone from the sides will

reduce the radio range. The operating range will also be
reduced if the Nodes are not installed at adequate
heights.

(see Figures 2 & 3)

C

– Relay Nodes form the backbone of the mesh and

‘relay’ data from the Nodes reporting to them towards
the Base. It is important to establish a ‘grid’ layout so
that multiple paths exist between Relay Nodes for data
to flow to the Base. End Nodes only send their data to
a nearby Relay Node or to the Base and should be

Monitoring System

INSTALLATION AND OPERATING INSTRUCTIONS

Solar Powered Wireless

Data Logging System

1

2

3

4

Summary of Contents for IRROmesh

Page 1: ...locations to verify that distances are acceptable and potential obstructions are avoided will make the physical deployment of the hardware much easier Avoid installation near areas with potentially s...

Page 2: ...ovide in fill near relaying Nodes see Figure 4 D There is a limitation to the number of Nodes that can be in a path and how many total paths can feed to the Base If all the data from several Nodes has...

Page 3: ...tions for your device on pages 4 to 5 Installation BASE At the pre determined Base location uncover the solar panels and slide the switch inside the Base enclosure to the ON position Mount on any stur...

Page 4: ...d and retrieved manually with a laptop computer A free download of 975L WaterGraph Software is provided to retrieve view and graph data NOTE The Logger is used to batch download data but cannot be use...

Page 5: ...rk to upload to SensMitWeb Once you have completed registration you will be able to view your Nodes and confirm that the network is operating properly You will also be able to access a host of diagnos...

Page 6: ...One connector per individual Node wire is needed Be sure to INDIVIDUALLY insulate ALL unused wires DO NOT leave unused Node wires un insulated and allowed to corrode touch each other or touch the met...

Page 7: ...11 pipe with a transition solvent PVC to ABS cement The pipe becomes a conduit to protect the sensor wires Also this makes the sensor easier to push into the access hole and remove if desired The top...

Page 8: ...mitting data to the Web To rectify add SensMitPath to the list of approved programs on your anti virus exceptions page then click OK or Allow to permit access RESETTING PROCEDURES On occasion it may b...

Page 9: ...nused wires DO NOT leave unused Node wires un insulated and allowed to corrode touch each other or touch the metal pole 2 Repeat for each sensor being installed NOTE Wires are paired by color One is a...

Page 10: ...___________ Node Descriptive Name ____________________________________________________________________ Node ID _______ _______ _______ _______ _______ _______ _______ _______ Type Relay EndX Node Loca...

Page 11: ...Notes or System Layout Diagram 11...

Page 12: ...television reception which can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocat...

Reviews: