background image

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.

PAGING STATION

T-328

O

P

E

R

A

T

IO

N

 M

A

N

U

A

L

AUDIO

AUDIO

PUBLIC ADDRESS SYSTEM

Summary of Contents for T-328

Page 1: ...he instructions in this manual to obtain the optimum resultsfrom this unit We also recommend that you keep this manual handyfor future reference PAGING STATION T 328 OPERATION MANUAL AUDIO AUDIO PUBLIC ADDRESS SYSTEM ...

Page 2: ...ETY PRECAUTIONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 CONNECTIONS 8 6 APPLICATIONS 9 7 ADDRESS SET 11 8 BLOCK DIAGRAM 13 9 SPECIFICATIONS 14 10 DIMENSIONAL DIAGRAM 15 ...

Page 3: ...t insert nor drop metallic objects or flammable materials in the ventilation slots of the unit s cover as this may result in fire or electric shock 3 T 328 When Installing the Unit Do not expose the unit to rain or an environment where it may be splashed by water or other liquids as doing so may result in fire or electric shock Use the unit only with the voltage specified on the unit Using a volta...

Page 4: ...ooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched on L...

Page 5: ...ement and therefore the line is already busy the talk led start blinking 3 Activation message 3 After selecting the zones open alarm switch Protection and push the button Base of T 6245 setting the system plays the message once or continuously till the alarm switch is not push back 4 Priority Microphone base has priority on music and on recorded Message 5 Recorded messages Three different messages...

Page 6: ...ame time the first base get the line and all the others will have the led blinking 4 NOMENCLATURE AND FUNCTIONS 4 ALARE N 1 alarm message activation switch for pre selected zone This switch with led must be protected press this button two seconds to activate alarm message 5 POWER Power indicator 6 LINK Link indicator 7 MIC N 1 electret microphone 4 1 FRONT PANEL ALARM LINK POWER MIC ZONE 4 ZONE 5 ...

Page 7: ... a potential external power transformer This 24V DC power transformer should be used when the distance the distance could vary based on cable section between the microphone base and T 328 is too much for the 24 Vdc provided by RJ45 connection The connection of the external power supply disable the 24 Vdc provided by T 328 9 VOLUME Volume control output 10 TREBLE Adjust treble response Rotate clock...

Page 8: ...Network Line A B 220 240V 50 60Hz T1AL250V OPEN RELE INPUT ZONE 1 OUT ZONE 2 OUT ZONE 3 OUT ZONE 4 OUT ZONE 5 OUT ZONE 6 OUT COM NO1 NO2 PLAY MESSAGE 1 RELE ZONE CONSOL OUT MIX MUSIC PAGE OUT MUSIC OUT PAGE OUT IN COM ZONE 2 3 4 5 6 PRIORITY TAPE CD TUNER MICRO CONSOL GAIN GAIN CONSOL VOLUME VOLUME CHIME OFF 1 2 3 REC MESSAGE 1 TIME CONTINUOS MESSAGE NORMAL ALARM VOL PLAY MESSAGE VOL REC MIC 48V P...

Page 9: ... 0 10 10 10 CHIME VOLUME TREBLE BASS VOLUME ID CONSOL LINE IN 0 10 1 2 3 1 GND 2 GND 3 24DC Compact disc Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 ZONE 6 OUT NO2 PLAY MESSAGE PRIORITY TAPE CD TUNER MICRO CONSOL GAIN GAIN CONSOL VOLUME VOLUME CHIME OFF 1 2 3 REC MESSAGE 1 TIME CONTINUOS MESSAGE NORMAL ALARM VOL PLAY MESSAGE VOL REC MIC 48V PHANTOM 220 240V 50 60Hz T1AL250V OPEN RELE INPUT ZONE 1 OU...

Page 10: ...ME ID CONSOL LINE IN 0 10 1 2 3 1 GND 2 GND 3 24DC POWER 24VDC 10 10 0 10 10 10 CHIME VOLUME TREBLE BASS VOLUME ID CONSOL LINE IN 0 10 1 2 3 1 GND 2 GND 3 24DC POWER 24VDC 10 10 0 10 10 10 CHIME VOLUME TREBLE BASS VOLUME ID CONSOL LINE IN 0 10 1 2 3 1 GND 2 GND 3 24DC LINK OUT LINK OUT LINK OUT LINK OUT LINK OUT LINK OUT INPUTS LINK GND LIFT 100V 70V 4 16 COM OUTPUT 220 240V 50 60Hz FUSE T6 3AL250...

Page 11: ...23 24 25 26 27 28 29 30 31 32 ADDRESS DEFINITION ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ADDRESS DEFINITION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ID CONSOL ADDRESS SET ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 11 T 328 ...

Page 12: ... 57 58 59 60 61 62 63 64 ADDRESS DEFINITION ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ADDRESS DEFINITION 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 ID CONSOL ADDRESS SET ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON T 328 12 ...

Page 13: ...MCU CONTROL 12v MAX485 GND GND Talk All zone CONTROL Gnd Alarm ID GND 8 BLOCK DIAGRAM 13 T 328 ...

Page 14: ...3dB Phantom power 12V Bass 12dB 12dB Treble 2 tone active for contact free in priority and BGM 0 1 Normal distortion Chime Main power supply 24 DC Dimension mm 230X150X56 Max number of microphone bases Weight 6 0 96Kg 9 SPECIFICATIONS T 328 14 MIXER AMPLIFIER WITH CD T 328 Model ...

Page 15: ...150 mm 220 mm 150 mm 10 DIMENSIONAL DIAGRAM POWER 24VDC 10 10 0 10 10 10 CHIME VOLUME TREBLE BASS VOLUME ID CONSOL LINE IN 0 10 1 2 3 1 GND 2 GND 3 24DC UNIT mm LINK OUT ALARM LINK POWER MIC ZONE 4 ZONE 5 ZONE 6 ALL CALL TALK ZONE 1 ZONE 2 ZONE 3 15 T 328 ...

Page 16: ...PUBLIC ADDRESS SYSTEM Version A AUDIO AUDIO ...