Safety Instructions 

• Disconnect power before installing, adding or changing any component.
• To avoid a hazard to children, account for all parts and destroy all packing materials.
• Do not install any luminaire assembly closer than 6” from any combustible materials.
• Positive (+) outputs require a fuse if the attached wire leads are not rated to handle the max current.
• This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 
 

- This device may not cause harmful interference

 

- This device must accept any interferences received, including interference that may cause undesired operation

For warranty information please visit www.itc-us.com\warranty

1.

 

INSTALL: 

Determine the installation location for your control module. Make sure to consider the size of the module (7.5”L x 5”W x 1.5”H)   

     when determining your location. Note, it will require room for access and for wiring. Screw the controller in place using four M5 stainless 

     steel screws (not provided) sized appropriately for the substrate material used. Make sure when mounted, that the Bluetooth antenna is    

     not obstructed by metal objects.

1.5”

7.5”

5”

PARTS / TOOLS NEEDED:

VersiControl RGB 

Smart System

RGB Lighting 

(Varies)

Mounting Screws x 4 

(not provided)

Butt Splices 

(not provided)

Power Drill

2.

 

CONNECT CONTROL PAD: 

If using the control pad (optional), insert 

     the connector on the control pad into the connector on the 

     module. Refer to control pad installation instructions for more  

     detailed information. 

3.

 

ZONE WIRE CONNECTIONS: 

Refer to the diagram below for refer-

     ence when wiring the system in step 4. Note, there can be 8 or 

     10 zone wires coming out of the controller. Each wire has been 

     individually placed on the grommet of the assembly. 

G

W

B

R

+

G

W

B

R

+

ZONE 1

ZONE 2

Bluetooth Antenna

Summary of Contents for VersiControl Smart System

Page 1: ... com warranty 1 INSTALL Determine the installation location for your control module Make sure to consider the size of the module 7 5 L x 5 W x 1 5 H when determining your location Note it will require room for access and for wiring Screw the controller in place using four M5 stainless steel screws not provided sized appropriately for the substrate material used Make sure when mounted that the Blue...

Page 2: ...nnector Deutsch DTM04 6P Mating Connector Deutsch DT04 4P Mating Connector Deutsch DTP06 2S 3 5mm Audio Input Signal Line White 22XX2 RGBW YY SC Controller Red 12 24V DC IN Black 12 24V DC IN Max 16A Inputs Outputs White Red Black Red Black Green Black Blue Black White Zone 1 Max 8A White Red Black Red Black Green Black Blue Black White Zone 2 Max 8A Fuse 1 5 4 3 2 6 V Red V Black Shield Black Not...

Page 3: ...put line to the controller is activated If the disable line is held at the input voltage 5 24 volts Zones one and two will be turned off This feature can be used if you want to deactivate the zone lights on the outside of the boat when in motion By default only zones one and two are turned off There is no effect on zones three and four if applicable You can adjust which zones are turned off via a ...

Page 4: ... light s controller s If the radio now outputs audio noise then the LED lights may have caused the interference 6 If the radio does not output radio noise then the problem is with another part of the electrical system If EMI is observed the following steps should help isolate the problem DIAGNOSING EMI NOISE GROUNDING BONDING How each component is connected and routed to power ground is important ...

Reviews: