background image

 

 

 

 

 

 

 

 

 

 

 

 
IQN/F 

MODELS 

 

-

 

IQF  FLAKER 

-

 

IQN  NUGGETS

USER MANUAL 

 

Summary of Contents for - IQN NUGGETS

Page 1: ...IQN F MODELS IQF FLAKER IQN NUGGETS USER MANUAL ...

Page 2: ...N TO DRAINAGE 5 3 4 ELECTRICAL CONNECTION 6 3 5 INSTALLATION THE EQUIPMENT ABOVE TANKS BINS 6 4 CONTROL PANEL 8 4 1 PE1 ON OFF BUTTON 8 4 2 PE2 RESERVOIR FULL 8 4 3 PE3 GEAR MOTOR ALARM 8 4 4 PE4 INTERNAL FAULT ALARM 8 4 5 PE5 LACK OF WATER SUPPLY ALARM 8 5 START UP 9 5 1 PREVIOUS CHECKUP 9 5 2 STARTING UP THE MACHINE 9 6 MAINTENANCE AND CLEANING INSTRUCTIONS 10 6 1 SCALE REMOVING PROCEDURE 10 6 2...

Page 3: ...uld be monitored to assure that they should not play near the equipment This machine is not intended to be used outdoors nor exposed to the rain Connect to potable water supply only See section 3 of this manual This machine must be grounded to prevent possible discharges on persons or damage to the equipment The machine must be grounded according to local and or national regulations and regulation...

Page 4: ...nstrument As from May 1 1998 complies with the European regulations on management of packing and packing waste inserting the Green Dot Label on all their packages Always state the machine number and model This number is printed on three locations 2 1 PACKAGING There is an exterior label with the manufacturing number Figure I 2 2 EXTERIOR OF THE EQUIPMENT Located on the back of the unit the same la...

Page 5: ...ive hot air from another device we strongly advise in case of not being able to change the site of the machine INSTALL A WATER CONDENSER 3 2 CONNECTIONS TO THE WATER NETWORK The water quality has a significant effect on the appearance density and taste of the ice and will affect the life expectancy of a water condenser if used Use the 3 8 FPT connection The water connection needs to be dedicated o...

Page 6: ...ated in the nameplate Variation on voltage above the 10 stated on the nameplate could result on damages or prevent the machine start up ATTENTION The appliance requires an independent power supply of proper capacity See the nameplate for electrical specifications Failure to use an independent power supply of proper capacity can result in a tripped breaker blown fuse damage to existing wiring or co...

Page 7: ...ENGLISH 7 Figure IV ...

Page 8: ...R FULL This LED will light up when the machine has stopped when the reservoir is full 4 3 PE3 GEAR MOTOR ALARM This alarm has two states In the first the LED will remain flashing and the machine will perform a timing and will automatically resume The machine will continue to operate in this state In the second state the LED will remain steady and the machine will be stopped until a reset is perfor...

Page 9: ...NNECTION PRESSURE SHOULD NEVER BE REDUCED 5 2 STARTING UP THE MACHINE 1 Connect to drinking water network Open the water stopcock and check that there are no leaks 2 Connect the machine to the electricity network Turn the rear switch ON 3 The button on the control panel PE1 see Figure VI must be lit red when pressed it will stay with a blue light flashing for 10 min 4 After 10 minutes of the timer...

Page 10: ...ution IX Place ice outlet Cover C in its original position X Pour the cleaning solution into the water reservoir D until the solution overflows That means that the system is full of the solution Allow the solution to sit for 10 minutes XI Keep the machine working to ensure that the electrodes inside of the water reservoir D are covered with the cleaning solution at the minimum level as seen in fig...

Page 11: ...4 Then allow the machine operate for 30 minutes in the freeze cycle and melt or discard all the ice that will be made 6 4 CLEANING STORAGE SENSOR This must be done every time the machine is cleaned Also in case the machine stops without the storage being full It is accessed through the top of the machine Remove the sensor from its support by removing the fixing screw With a soft paper and alcohol ...

Page 12: ...FLAKES NUGGET ...