background image

 

 

 
 

MT-606S 

 

RISC-based operator interface terminal with 5.7” flat panel display 

 

User’s Manual 

 
 

 

Summary of Contents for MT-606S

Page 1: ...MT 606S RISC based operator interface terminal with 5 7 flat panel display User s Manual ...

Page 2: ... CE Requirements 10 2 2 4 Safety Guidelines 10 2 3 Communications Connections 12 2 3 1 Connecter COM 1 RS232 12 2 3 2 Connecter COM1 RS485 COM2 RS232 13 2 3 4 Dip Switch 13 2 4 CE Requirements 14 2 5 Dimensions of MT 606 15 Chapter 3 Windows CE NET 17 3 1 Introduction 17 3 2 Utilities 17 3 2 1 Soft Keyboard 17 3 2 2 System Settings 18 3 2 3 IPSM 20 3 2 4 Startup 20 3 2 5 Remote Desktop Connection ...

Page 3: ... thus subject to change without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Weintek Labs Inc Information provided in this manual is intended to be accurate and reliable However Weintek Labs Inc assumes no responsibility for its use nor for any infringements upon the rights of third parties whic...

Page 4: ...amage to equipment with the symbol shown to the left A Warning symbol indicates that the reader should pay special attention to the accompanying text Precautionary steps should be taken to insure that the installation is in compliance with warnings Warnings include hazardous conditions that could cause personal injury or equipment damage if care is not taken The text next to this symbol describes ...

Page 5: ...6S is bundled with Windows CE OS The built in Windows CE OS platform forms a bridge that lets MT606S be an open HMI solution for system integration Features Built in flash memory and Windows CE OS inside All in one platform the CPU DRAM and Windows CE are integrated Low power consumption and Fan less NEMA 4 IP65 compliant front panel One CompactFlash slot Audio Ethernet port 10Base T 1 2 Specifica...

Page 6: ... 100 Luminance cd m2 150 Storage temperature C 20 60 Operating temperature C 0 45 Backlight1 CCFL Contrast ratio 30 1 Touch screen Type 4 wire analog resistive Resolution continuous Light transmission above 80 Life 1 million activation minimal Environmental Specifications Operating temperature 0 45 C 32 113 F Relative humidity 10 90 40 C non condensing Shock operation 10 to 25Hz X Y Z direction 2G...

Page 7: ...els with a depth of 4 105mm It is recommended that the unit be mounted on the front panel of a steel enclosure through an appropriate opening Allow a clearance of 1 25mm around the sides of the unit for mounting hardware Allow clearance for cable connections to the back of the unit Unit depth may vary according to cable type used Typically plan a depth to accommodate at least 4 105mm behind the pa...

Page 8: ...es vapors or dusts The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device Do not install these terminals in environments where have inflammable gases 2 2 Power Connections Make sure that all local and national electrical standards are met when the installing the unit Contact your local authorities to d...

Page 9: ...ions Caution Supply Voltage Condition Do not power the MT 600 and inductive DC loads or input circuitry to the controller with the same power supply Note The 24 VDC output from some controllers may not have enough current to power the MT 600 Caution Wire Routing Wire lengths should be minimized Maximum 1600 500 m shielded 1000 300 m unshielded Wires should be run in pairs with a neutral or common ...

Page 10: ...possible The conductors must always be large enough to carry the maximum short circuit current of the path being considered Ground conductors should be connected to a tree from a central star earth ground point This ensures that no ground conductor carries current from any other branch 2 2 3 CE Requirements To make an MT 600 comply with EMC directives and to reduce susceptibility to electrical int...

Page 11: ...ol critical parts of plant or machinery have limit checks built into the program with an out of limit safe shut down procedure to ensure safety of personnel ICS 3 304 81 Safety Recommendations Consideration should be given to the use of an emergency stop function which is independent of the programmable controller Where the operator is exposed to the machinery such as in loading or unloading a mac...

Page 12: ...n 1 Not used 2 TxD Transmitted Data 3 RxD Received Data 4 Not used 5 GND Signal Ground 6 Not used 7 CTS Clear to send input 8 RTS Ready to send output 9 Not used Cable Requirements Different cables are required for various devices Caution Restrict cable length to less than 500 150m for RS485 422 devices and 50 15m for RS232 devices to avoid communications problems Shielded cable must be used for l...

Page 13: ... RS485 4 wire Function RS485 2 wire 1 Rx RS485 Receive RS485 Data 2 Rx RS485 Receive RS485 Data 3 Tx RS485 Transmit 4 Tx RS485 Transmit 5 GND Signal Ground 6 Not used 7 TxD RS232 Transmit 8 RxD RS232 Receive 9 Not used MT600 COM1 RS 485 9P D SUB Male RS 485 2 wire Device 1 Data Data 2 Data Data 5 GND MT600 COM1 RS 485 9P D SUB Male RS 485 4 wire Device 1 Rx Rx RS485 Receive 2 Rx Rx RS485 Receive 3...

Page 14: ...ode Refer the load Win CE image document 2 4 CE Requirements EU directives that apply to the MT 600 Series EMC Directive 89 336 EEC 92 31 EEC 93 68 EEC electromagnetic emissions and immunity Machinery Directive 89 392 EEC 91 368 EEC 93 44 EEC 93 68 EEC machine safety MT500 products will be CE marked to indicate compliance with the EMC Directive The MT 600 Series has been designed to operate satisf...

Page 15: ...ISPR EN 55011 Group 1 Class A Radiated Emissions levels EN50081 2 Generic emission standard industrial environment Also US FCC Class A EN50082 2 Generic immunity standard industrial environment 2 5 Dimensions of MT 606 5 90 150 8 03 204 Front View Side View Panel mounting clamp 4 places only 1 shown 1 89 48 1 53 39 0 36 9 2 ...

Page 16: ...16 Cutout dimensions MT 606S 7 56 192mm W x 5 43 138mm H Rear View Reset button Dip Switch Contrast Adjust VR COM1 RS485 COM2 RS232 COM1 RS232 MIC SPK USB Client Ethernet port 10Base T ...

Page 17: ...ronment Windows CE NET contains everything you need to create a custom Windows CE based device that requires rich networking hard real time and a small footprint as well as rich multimedia and Web browsing capabilities 3 2 Utilities There are several useful utilities built in the standard Windows CE OS of MT600 3 2 1 Soft Keyboard The MT 606 is dedicated to the small sized operator interface It is...

Page 18: ...or users to make basic setting of the machine Step 1 Tap the cecp icon from Desktop 2 Launch the System Settings Control Panel Touch Screen settings The touch screen calibration can be executed from the Control Panel Step 1 Launch the System Settings Control Panel ...

Page 19: ...n to turn off the LCD backlight and thus elongates the period of service For example if the user wants the backlight turned off automatically after 10 minutes when the device was no longer used The user must select 10 minutes in the put down box and then press OK button Then the screen save function is enabled Once the backlight was turned off events or perturbations from the touch screen can turn...

Page 20: ... disk You can store your data and application in the Flash ROM via IPSM function to prevent unexpected loss of data as power failure When power is shutdown and cold boot the data in the Flash ROM area would be saved 3 2 4 Startup After the system boot up the startup execution function would automatically perform This function is useful for control system to do the initialization processes or some ...

Page 21: ...rameters For example to start MyApp exe and pass two optional parameters into the application a sample MyApp lnk file contains the following 40 Windows MyApp exe parameter1 parameter2 3 2 5 Remote Desktop Connection Use Remote Desktop Connection you can remotely control your computer To use Remote Desktop you need the following Windows XP Professional installed on your office computer or whichever...

Page 22: ...log box type your user name password and domain if required and then click OK The Remote Desktop window will open and you will see the desktop settings files and programs that are on your office computer Your office computer will remain locked Nobody will be able to work at your office computer without a password nor will anyone see the work you are doing on your office computer remotely Note To c...

Page 23: ... Connections 3 Find the default device name Change it to a unique one depending on the plan of individual LANs LAN90001 4 If the MT606 is a node of a LAN with DHCP servers it is now available 5 If the MT606 is a node of a LAN with fixed IP server please consult with MIS to get specific IP address Click Start Settings Control Panel Double click Network and Dial up Connections and update the IP addr...

Page 24: ...Before the Windows CE boot up don t connect the USB cable 3 Connect the USB client port of the MT 606 and the USB host port of the host PC by the USB client to USB host cable 4 When the Add New Hardware Wizard asks for the driver click Browse and select the file named wceusbsh inf under the USB driver directory 5 Follow the onscreen instructions to establish a partnership and synchronize your MT60...

Page 25: ...re only portable in the source code level Users must rebuild the runtime file for a different Windows CE platform even though the source code may not be changed at all The following development tools must be installed on the PC Microsoft eMbedded Visual C 4 0 Microsoft eMbedded Visual C 4 0 Service Pack 1 MT606 SDK 3 4 1 Microsoft eMbedded Visual C 4 0 System Requirements To use Microsoft eMbedded...

Page 26: ...hat are specific to the MT606 hardware Installing the MT606 SDK Step 1 Download or from MT606 SDK CD find the HMI_MT606_SDK msi file Double click the file s name start the Setup Wizard 2 The installer will be prompted for acceptance of a license agreement Following that the SDK should install itself automatically on the host machine without further operator intervention 3 When installation is comp...

Page 27: ...27 ...

Reviews: